My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1804 HEWITT AVE 2022-05-12
>
Address Records
>
HEWITT AVE
>
1804
>
1804 HEWITT AVE 2022-05-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 9:08:52 AM
Creation date
5/9/2022 3:59:38 PM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1804
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
246
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• -7P* rS„,,$::::- 1: IZ.1 <br /> ,,,,-:, <br /> FIRE DEPARTMENT t <br /> .-4, -!, � '� <br /> actiw <br /> _, <br /> FROM: Jim Venturo, Assistant Fire Marshal <br /> DATE: 8/22/17 <br /> SUBJECT: 1804 Hewitt Ave <br /> Hodges Building Remodel <br /> 1. Access - O.K. as shown on the site plan reviewed. <br /> 2. (2) Knox Boxes are required. 2015 IFC, 506.1. One Knox Box at entry Hewitt Ave side. <br /> One Knox Box at rear entry. Order boxes 3500 series. <br /> 3. Knox fire department connection caps are required for all OUTSIDE FDC and standpipe <br /> connection points. (2) FDC caps needed #3043. Go to www.everettfire.orq to order <br /> Knox products. <br /> 4. Premise Identification - Premises shall be clearly identified by the correct address at the <br /> street entry. Buildings shall be clearly identified so as to be visible and legible from the <br /> access road. Individual apartments and suites, where applicable, shall be clearly and <br /> legibly identified from the access road. EMC 16.03, Section 505.1.1 (Address Posting <br /> Policy). 8" numbers on building. <br /> 5. Fire Hydrants - Locations as planned are acceptable. <br /> 6. Fire flow for this project is 2000 GPM. <br /> 7. Portable Fire Protection -A portable fire extinguisher with a minimum U.L. rating of <br /> 2-A:10-B:C shall be provided within 75 feet of travel on all floors of each building during <br /> construction and prior to occupancy. 2015 IFC, Section 906 <br /> 8. Fire Alarm System -An approved automatic fire detection system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval <br /> prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a Fire Department Inspector, shall be performed, along <br /> with a certificate of completion, prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72, 2013 Edition. <br /> Installation of fire alarm components,including basic wiring, may not commence <br /> before plans are approved by the Fire Department Plan Reviewer. Fire alarm drawings <br /> must be professionally rendered, in sufficient detail, and must be internally consistent. <br /> Riser diagrams must match installation plans and load calculations. Components must be <br /> listed and approved for use together. Changes to plans must include new drawings and <br /> calculations and must be approved by the Fire Department Plan Reviewer prior to <br /> installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> EVERETT FIRE DEPARTMENT•2930 Wetmore Avenue Ste 7A• Everett WA -4067• (425)257-8100• Fax(425)257-8139 <br /> / s <br />
The URL can be used to link to this page
Your browser does not support the video tag.