Laserfiche WebLink
• • <br /> RESPONSE: Location of w/h in attic added to A4.0. <br /> /15. Specify how the addition is provided with a whole house ventilation system per section <br /> R1507. Include the requirements of the system chosen on the plans. Do not simply reference <br /> the code section. <br /> RESPONSE: The entire house (including the addition) will function as 1 system. Whole house <br /> fan called out in laundry on Proposed Plan 2 on A2.1. <br /> 16. Specify the framing at the landing at the top of the stairs that runs west to east, and show <br /> the connection of the stringers to the landing. <br /> RESPONSE: See Structural. <br /> �17. Handrails for stairways shall be continuous for the full length of the flight, from a point <br /> directly above the top riser of the flight to a point directly above the lowest riser of the flight. <br /> Handrails shall be returned or shall terminate in newel posts or safety terminals. Show • <br /> requirements on the plans and show the location of the handrails on the floor plans. <br /> RESPONSE: Plans updated on A2.1 to reflect request above and verbage added to detail on <br /> A4.0. <br /> 18. Please revise the references in the General Notes to reflect the current IRC and not the <br /> SRC or 2012 IRC. <br /> RESPONSE: Updated. <br /> DWELLING REVIEW: <br /> 19. Provide separate application for construction of the detached garage. A separate permit will <br /> be issued for the construction of the garage. <br /> RESPONSE: Separate sheet set created. <br /> 20. The area of floor used for parking of automobiles or other vehicles shall be sloped to <br /> facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. R309 IRC <br /> RESPONSE: Sloping added to plan on A2.1 and elevations on A3.1. <br /> 21. Provide building section of the garage looking perpendicular to the trusses. <br /> RESPONSE: Section of garage added to A4.0. <br /> 22. Provide detail of the Simpson Wood Strong Wall. <br /> RESPONSE: See Structural. <br /> 23. The engineering details state "BUILT-UP POST AT END OF WALL PER PLAN" please <br /> clarify the post required and show the locations where posts are required. <br /> RESPONSE: See Structural. <br /> 24. The gable roof shall not extend over the property line. Please revise drawings. <br /> RESPONSE: Plan updated. <br /> 25. Roof projections are limited to 4 inches when located less than 2 feet from the property line. <br /> RESPONSE: Plans updated to reflect no eaves planned for garage except 6"at west side. <br /> 26. Walls located less than 5-feet from the property line are required to be one-hour fire- <br /> resistance rated construction, no openings are allowed in walls located less than 3-feet from the <br /> property line. <br /> RESPONSE: No windows are planned on N wall and 1-hr fire-rated detail callout added to plan <br /> on A2.1 and note added on the Site Plan on A1.0. <br /> 27. Provide minimum 36-inch landing not more than 1-1/2 inches below the finished floor at the <br /> door on the west side of the proposed garage. <br /> RESPONSE: Landing already shown in Site Plan on A1.0, and added in Floor Plan on A2.1, <br /> and note added on Proposed Elevation A on A3.1. <br /> 28. The "Garage Roof Framing Plan" on Sheet S2.0 shows the window in a different location <br /> than the Proposed Garage Plan on sheet A2.1 and the elevation drawing on sheet A3.1. Please <br /> correct. <br /> RESPONSE: See Structural. <br /> Page 2 of 3 <br />