My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST 2019 Plans 2022-12-07 (2)
>
Address Records
>
13TH ST
>
1700
>
Plans
>
1700 13TH ST 2019 Plans 2022-12-07 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2022 8:48:45 AM
Creation date
5/10/2022 9:42:50 AM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Permit
B1912-025
Year
2019
Notes
TI REMODEL IN EXISTING CT ROOM 1 FOR INSTALL OF RELOCATED GE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACH TO STRUCTURE <br />(TYP, SEE NOTE 2) <br />HANGER STRAP <br />(TYP, SEE NOTE 2) <br />PERFORATED PLATE, TOP <br />AT CENTERLINE OF INLET <br />SHEET METAL <br />DIFFUSER CAP <br />(NECK SIZE +2") <br />DIFFUSER NECK <br />CEILING, REFER <br />TO ARCH DWGS <br />CEILING DIFFUSER <br />SHEET METAL STUD DUCT <br />DUCT STRAP <br />FLEXIBLE DUCT (6 FT MAX) <br />ROUND METAL DUCT —� <br />VOLUME DAMPER <br />AT TAKEOFF <br />FITTING <br />d �L-SUSPEND ON CENTER <br />FOR LENGTHS GREATER <br />THAN 4 <br />LIGHT FIXTURE <br />N OTE: <br />1. FOR ROUND CEILING DIFFUSER CONNECTIONS, SUBSTITUTE SHEETMETAL <br />DIFFUSER CAP AND STUB DUCT WITH SHEETMETAL ELBOW. <br />2. IF REQUIRED BY CODE. <br />Ali <br />SCALE: NONE <br />22x10 FOR <br />2412 GRII <br />LAY —IN CE <br />REFER TO <br />EXHAUST/F <br />SCALE: NONE <br />HANGER STRAP <br />(TYP, IF REQUIRED BY CODE) <br />2" ABOVE TOP OF <br />EXHAUST/RETURN DUCT <br />EXHAUST/RETURN <br />TRANSFER DUCT <br />SEE PLANS FOR SIZE <br />COIL <br />of <br />SCALE: NONE <br />MINIMUM CLEAR ACCESS PER NEC AND <br />MANUFACTURERS RECOMMENDATIONS <br />SA DUCT 2 DUCT -- —� <br />SEE TU SCHEDULE DIAMETERSI I <br />FOR SIZE OR 2'-0s <br />I I <br />MIN <br />TERMINAL UNIT INLET <br />CONNECTION SIZE <br />SAME AS INLET COLLAR <br />2—WAY CONTROL <br />VALVE <br />CIRCUIT BALANCING <br />VALVE <br />SEE PLANS FOR 3—WAY <br />VALVE APPLICATION <br />HWS <br />LL VALVE <br />'P) <br />,RAINER WITH <br />BLOW —OFF <br />CONTROL PANEL <br />TERMINAL UNIT OUTLET <br />CONNECTION SIZE SAME <br />AS OUTLET COLLAR <br />NOTES: <br />1. DDC CONTROLS BY CONTROLS CONTRACTOR. TERMINAL UNIT <br />2. PROVIDE SERVICE CLEARANCE FOR TERMINAL UNIT <br />CONTROLS AND COIL PIPING. <br />3. COORDINATE LOCATION OF TERMINAL UNITS WITH CEILING <br />GRID AND OTHER TRADES. PROVIDE CEILING ACCESS DOOR <br />OR REMOVABLE CEILING TILE NOT MORE THAN 18" FROM <br />CONTROL PANEL SIDE. <br />4. DETAIL APPLIES TO ALL TERMINAL UNITS UNLESS OTHERWISE NOTED. <br />SCALE: NONE <br />PIT <br />2 Ookes Ave. <br />Suite 100 <br />Everett, VVA 98201 <br />RIE"V0ONS <br />t, e. c <br />5 Stan <br />4100 194th Street SW Suto 400 <br />Lynnwood Washington 98036-4613 <br />(206) 667-0555 <br />Copyright Reserved <br />The Contractor shall verify and be responsible for all dimensions. DO <br />NOT scale the drawing - any errors or omissions shall be reported to <br />Stantec without delay. <br />The Copyrights to all designs and drawings are the property of <br />Stantec. Reproduction or use for any purpose other than that <br />authorized by Stantec is forbidden. <br />UJ <br />MM <br />-- <br />I0 <br />0 <br />.IOB. No. ` 9-101 <br />DR^wti BY N41 <br />CHECKED BY F J <br />11-08-19 <br />D IfsT MIL S <br />
The URL can be used to link to this page
Your browser does not support the video tag.