My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2312 W CASINO RD 2020 COMMUNITY TRANSIT Plans 2022-12-02
>
Address Records
>
W CASINO RD
>
2312
>
COMMUNITY TRANSIT
>
Plans
>
2312 W CASINO RD 2020 COMMUNITY TRANSIT Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 12:24:46 PM
Creation date
5/10/2022 4:28:38 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2312
Tenant Name
COMMUNITY TRANSIT
Permit
B2003-012
Year
2020
Notes
EXISTING BUILDING RENOVATED INTO NEW ADMINISTRATIVE OFFICE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LARGE CONF <br />_FLOOR ; G1 <br />CEILING1ACT-1 <br />BASE 1 RB-1 <br />0 <br />OPEN OFFICE <br />LU <br />is <br />F-_CE <br />LO_ORILINGS BAFF 1 <br />BASF. RB 1 <br />CORRIDOR <br />1®0 <br />FLOOR CONC-1 <br />CEILING! OPEN__. <br />BASE 3_.._RB.1__ <br />OPEN CONE <br />FLOOR C-1 <br />CEILING BAFF 1 <br />_ <br />BASE RB 1 <br />FLOOR C-1 <br />CEILING;.. BAFF-1- <br />BASE RB 1 VESTIBULE <br />101 <br />FLOOR ; C-3 <br />CEILING OPEN <br />BASE RB-1 ,--. <br />PHONE <br />CORRIDOR <br />102 87 <br />FLOOR C-1 FLOOR CONC-1- <br />CEILING, ACI-1 CEILING OPEN <br />BASE fi RB-1 2-58 BASE t RB 1 <br />LARGE CONE <br />40 ±2-17) <br />Q� <br />FLO-OR ; C 1 <br />_ <br />CEILING! ACT-1 <br />-d- <br />4-15� <br />ASE BRB 1 <br />2�1 <br />4-1 <br />OFFICE OFFICE <br />11� ago <br />2-59 <br />JI <br />FLOOR _____1FLOOR-_.C-1 <br />.___ <br />__.. <br />CEILING ACT-1 CEILING! ACT-1 <br />___ ---- <br />_.-_-- --� <br />BASE RB 1 BASE RB-1 <br />1 _..._ -...- -- <br />OFFICE OFFICE <br />2-59� FLOOR C-1 FLOOR C-1 <br />CEILING; ACT 1 CLING ACT 1 <br />_.... _. <br />!� BASE (...__RB61___ -EIBASE RB-1 <br />11� <br />00 <br />FLOOR t C 1 _ <br />FLOOR C-1 <br />CEILING 1 <br />CEILING ACT-1 <br />-ACT <br />BASE s RB-1 <br />BASE RB-1 <br />11 <br />a <br />FLOOR' C 1 <br />FLO_OR C 1 <br />CEILING ACT-1 <br />CEILING ACT-1 <br />BASE RB 1 <br />BASE RB 1 <br />SMALL <br />CONFERENCE <br />C <br />PYI PRIM <br />11 <br />M. <br />FLOOR C-1 <br />FL OOR C-1 <br />CEILING ACT 1 <br />CEILING! ACT-1 <br />BASF RB 1 <br />BASE 1 RB-1 <br />1 <br />0� <br />FLOOR CONC- <br />CEILING OPEN <br />BASE RB 1 <br />CORRIDOR <br />12� <br />FL OOR CONC-1 <br />CEILING OPEN <br />BASE RB 1 <br />2-17> <br />FLOOR BBT 1 <br />CEILING' OPEN04 <br />_BASE ' R 1 Z11\ <br />LCONFERF!jN <br />I R <br />2-59} <br />(04 <br />0 <br />FLOOR CFLOOR <br />INGL__.._ <br />COIF C-10EIL <br />CEILING OPENBASE <br />R <br />- --_. <br />BASE ? RB-1 <br />2-59 <br />2-1 <br />CORRIDOR I t <br />4-15 1 <br />�/ <br />SECURED FLOOR �CONC-1 <br />Ili ECHAN ICAL _ <br />--- STORAGE 109 OILING, OPEN DATA CENTER <br />10 - BASE RB-1 <br />FLOORS) CONIC <br />FLOOR BBT 1 — I FLOOR SDT 1 <br />SMALL CONE ��-� CEILING OPEN <br />= CEILING' ACT-1 - CEILING' ACT 2 <br />BASE RB-1 <br />1 07 BASE RB 1y __ ___ ._.: _. _..,__ BASE RB 1 - <br />L FLOOR ; C 1 <br />� CEILING{ACT 1�..: <br />___ <br />BASE RB-1 <br />STORAGEMORKILAB <br />117 <br />Ft OOR ING! <br />3 3 i j _-..._. <br />CEILACT-2 <br />-- BASE, RB-1 <br />WELLNESS (`', <br />FLOOR C 1 <br />CEILING ACT 1 <br />BASF RB 1 <br />STR <br />_EILIN _ + ACT-1 - -- _ _ _ <br />BASE RB-1. <br />UPS <br />11� <br />FLOOR E)CONC <br />rc <br />CEILING OPEN AUI <br />BASEDRI <br />RB-1 <br />FLOOR BBT-1 <br />CEILING ACT-1 2-1 <br />BASE I __ <br />RB-1.,. <br />OPEN <br />CNFIBREAK <br />0�1 <br />FLOOR CONC-1 <br />T <br />ING, OPEN <br />E_� RB-1 <br />FLOOR WD-S <br />CEILING; OPEN <br />BASE i RB-1 <br />LARGE CONE U RISER <br />a� 077 <br />FLOOR ; C-1 FLOOR (E) CONC <br />CEILING ACT-1 CEILING OPEN <br />BASE RB 1 BASE I RB 1 <br />_. ELSTAIR <br />-� FLOOR j R 1 <br />17� CEILING GYP BD <br />r C BASF RB-1 <br />FLOOR SDT-1 <br />CEILING1 OPEN <br />BASE RB 1 EMPLOYEE ENT VESTIBULE <br />-------- <br />KITCHENETTE FLOOR ' CON(1 +. FLOOR C-3 <br />_ _. <br />CEILING' GAFF-2T ;I CEILING! BAFF-2 <br />- BASE i .._RB-1 iBASE RB-'1 <br />FLOO <br />R 1CONC-1 <br />CEILING BAFF 2 <br />BASE RB-1 <br />FLOOR C-3 CONIF <br />1 7 ------- <br />CEILING!-FLOOR ,CONC-1 BASE iX1111AIM0 <br />--- - <br />CEILING OPEN FLOOR q 1_.____ <br />_ _ — <br />BASE RB 1 CEILING! ACT-1 <br />- <br />BASE - RB-1 <br />STO R <br />2-17� 1 <br />FLOOR BBT 1_ 2.41 <br />LING ACT-1 <br />BASE RB 1 <br />ELEVATOR <br />EQUIPMENT <br />137 <br />FLOOR BBT-1 <br />CEILING OPEN FITNESS <br />BASE ' RB 1 <br />FLOOR <br />CEILING_ r OPEN <br />BASE ------ <br />' RB-1__.. <br />L„r <br />FITNESS STUDIO <br />10 <br />FLOOR LVT-2 <br />CEILING ` OPEN <br />BASE RB 1� <br />MEN`S MEN`S SH WR <br />1�1 122 <br />FLOOR = T 1 FLOOR T-1 <br />CEILING! GYP BID _.. CEILING; GYP BD _ ...____._---- .. <br />BASE ` T 1 BASE ! I 1 <br />—VENDING <br />FLOOR ,CONC 1 <br />CEILING] ACT-1 <br />BASE RB-1- <br />PHONE <br />1 <br />FLOOR C- 1 <br />CEILING ACT-1 <br />BASE ! RB-1 <br />BREAK AREA <br />131 _ <br />FLOOR 7 CONC-1 <br />CEILING' ACT 1' <br />BASE RB-1 <br />BREAK AREA <br />133 <br />FLOOR CONC-1 <br />_. . <br />CEILING: BAFF-2 <br />BASE RB 1 <br />132 <br />FLOOR �E) CON( <br />CEILING, OPEN <br />BASE-= RB-1__. <br />FINISH PLAN LEVEL 1- <br />tp <br />TRUE <br />FINISH L <br />1. REFERENCE SPECIFICATIONS MANUAL FOR FINISH INFORMATION. <br />2. PROVIDE AND INSTALL NEW WINDOW ROLLER SHADES RWS-1 AT ALL WINDOWS IN <br />AREAS OF WORK, <br />2-17 <br />CG-1, CORNER GUARD <br />2-41 <br />WC-41 WALL COVERING -FELT PANELS <br />2-58 <br />WC-5, WALL COVERING - ACOUSTIC PANELS <br />2-59 <br />F-1, FILM <br />2-63 <br />PROVIDE_ AND INSTALL 8' HIGH MIRRORS, BUTT}OINT, ACROSS EXPANSE OF <br />WALL. <br />4-15 <br />ALIGN FLOORING TRANSITION WITH WALL EDGE <br />s € { <br />(E) <br />EXISTING FINISH TO REMAIN <br />ACT-1 2 <br />ACOUSTICAL CEILING TILES: REFER TO ARCHITECTURAL DRAWINGS <br />AP-1 <br />ACRYLIC PANEL SYSTEM <br />BAFF-1 <br />ACOUSTIC FELT CEILING BAFFLES <br />BAFF-2 <br />WOOD CEILING BAFFLES <br />BBT-1 <br />RESILIENT FLOORING -JANITOR & STORAGE <br />C-1 <br />CARPET TILE - FIELD <br />C-2 <br />CARPET TILE - EXECUTIVE SUITE/CONFERENCE CENTER <br />C <br />CARPET TILE -WALK OFF MAT <br />CG-1 <br />CORNERGUARD <br />CONC-1 <br />POLISHED CONCRETE <br />F-1 <br />FILM -PRIVATE OFFICES <br />F-2 <br />FILM - CONFERENCE <br />GL-1 <br />GLASS, ACCENT WALL - EXEC. KITCHENETTE <br />LVT-1 <br />LUXURY VINYL TILE - OPEN AREA <br />LVT-2 <br />WOVEN VINYL FLOORING - FITNESS STUDIO <br />M-1 <br />METAL PANEL. - RECEPTION DESK <br />P-1 <br />FIELD PAINT <br />P-2 <br />CEILING PAINT <br />P-3 <br />DOOR PAINT <br />P-4 <br />ACCENT PAINT <br />P-5 <br />TRIM PAINT <br />PL-1 <br />PLASTIC LAMINATE - WOOD GRAIN <br />PL-2 <br />PLASTIC LAMINATE -HORIZONTAL <br />PL-3 <br />PLASTIC LAMINATE - VERTICAL <br />RB-1 <br />RUBBER WALL BASE <br />RB-2 <br />WALL BASE Wf PROFILE - EXECUTIVE AREA <br />RT-1 <br />RUBBER ATHLETIC FLOOR TILE - FITNESS <br />RT-2 <br />RUBBER TREADS,RISER & LANDING FLOOR TIDE - EGRESS STAIRS <br />RWS-1 <br />ROLLER WINDOW SHADES <br />SDT-1 <br />ELECTROSTATIC DISSIPATIVE RUBBER TILE - DATA CENTER <br />SS-1 <br />SOLID SURFACE - EXCUTIVF_, KITCHENETTE, KITCHEN <br />SS-2 <br />SOLID SURFACE - RECEPTION DESK <br />SS-3 <br />SOLID SURFACE - KITCHEN ISLAND <br />T-1 <br />TILE, FLOOR - RESTROOMS <br />T-2 <br />TILE, WALL - RESTROOMS <br />T-3 <br />TILE, ACCENT WALL_- KITCHEN <br />T-4 <br />TILE, WALL - SHOWER <br />T-5 <br />TILE, ACCENT WALL - EMPLOYEE ENTRY KITCHENETTE <br />T-5 <br />TILE, ACCENT WALL -CONE. KITCHENETTE <br />T-7 <br />TILE, ACCENT WALL - UNISEX RESTROOM WALL <br />UPH-1 <br />UPHOLSTERY - KITCHENBOOTHS <br />UPH-2 <br />UPHOLSTERY - BANQUETTE SEAT <br />UPH-3 <br />UPHOLSTERY - BANQUETTE BACK AND SURROUND <br />UPH-4 <br />UPHOLSTERY - MOVEABLE PARTITION <br />WC-1 <br />WALL COVERING - TACKABLE PANEL <br />WC-2 <br />WALL COVERING - STAIRS <br />WC-3 <br />WALL COVERING - EXECUTIVE AREA <br />WC-4 <br />WALL COVERING PHONE ROOM <br />WC-5 <br />WALL COVERING - COMMON AREAS <br />WD-1 <br />WOOD WALL PANELING - END CUT <br />WD-2 <br />WOOD PANTER PANELING - BLACK SUGI BAN <br />WD-3 <br />WOOD - STAIR <br />PLAN <br />SYMBOLSFINISH <br />RC)C)M NAME <br />101 <br />ROOM TAG <br />FLOOR Floor Finish <br />CEILINGCeiling Finish <br />^ <br />BASE Base Finish <br />7 <br />WALL FINISH TAG <br />s <br />FLOOR TRANSITION TAG <br />7 <br />FINISH DIRECTION <br />KEY PLAN <br />Otak Architects, Inc. <br />308 ,SW Third Avenue, Suite 300 <br />Portland, OR 97204 <br />main 503.287.6825 <br />wwrw.otak.com <br />t.'f�l�►�lt'r' <br />CONSULTANT <br />TITLE <br />DATE DESC <br />A 04.17.2020 PLAN <br />C 05.20,2020 PLAN <br />E 07.29.2020 PERM <br />0 2017 OTAK, INC. <br />If this drawing is not 24" x 36", it has been <br />reducedlenlarged. Scale accordingly. <br />
The URL can be used to link to this page
Your browser does not support the video tag.