Laserfiche WebLink
m <br />Q <br />0- <br />sPa 0 <br />0 <br />0 <br />0- <br />0 <br />0 <br />1--1 <br />TVA <br />' n j d SCALE: 1 1/2" = V-0" <br />SCALE: 1/16" = V-0" <br />NOTE: CONCRETE TO BE SAWCUT AND <br />GROUND FOR SMOOTH, EVEN FINISH. <br />CHAMFER EDGE TO MATCH EXISTING <br />AT WINDOW HEAD WHERE REQUIRED <br />TO MATCH ADJACENT OPENINGS. <br />REMOVE EXISTING CONCRETE TO <br />MATCH EXISTING WINDOW HEIGHT. SEE <br />STRUCTURAL FOR REQUIRED <br />REINFORCEMENT PRIOR TO <br />SAWCUTTING OR REMOVING CONCRETE <br />LEVEL 02 <br />(EXISTING) <br />Im <br />.__ . .0_.._,� 4H <br />SCALE: 1/16" = 1'-0" <br />ALIGN TOP OF CONC, SAWCUTS W/ TOP OF <br />EXISTING WINDOWS AT LEVEL 2, TYP. <br />A Al <br />l <br />I <br />SAWCUT FOR EXTENDED <br />HEIGHT WINDOWS TO BE 4" <br />ABOVE EXISTING FLOOR, TYP. - -v <br />=gym <br />10 <br />D46 <br />D42 <br />D45 <br />D49 <br />I <br />i <br />12__ <br />D42 D49 MATCH DIM AT D�6 <br />OTHER SIDE <br />TH ELEVATION - DEMO <br />f- EXTEND CONCRETE CUTS TO <br />EDGE OF PANEL THIS LOCATION <br />ONLY. SEE STRUCTURAL DETAILS. <br />ALIGN CONCRETE CUTS W/ <br />EDGES OF EXISTING WINDOWS, <br />UNLESS INDICATED OTHERWISE. <br />nq C11 SCALE: 1/16" ' V-0" <br />EXTEND CONCRETE CUTS TO EDGE <br />OF PANEL AT THIS LOCATION, SEE <br />STRUCTURAL DETAILS. <br />p4U <br />_ ( )_T.®.?AMF/ ET <br />-- ,599' - 10 <br />596' 0" <br />Q�--- <br />��=-- 584' - 3" <br />E LEVEL 01__ <br />570' - 0„ <br />D42 <br />DEMOLITION NOTES <br />1, DASHED LINES INDICATE OBJECTS TO BE DEMOLISHED AND ( OR SALVAGED. <br />2, ITEMS SALVAGED FOR RE -USE SHALL BE SAFELY STORED AND PROTECTED FROM DAMAGE DURING <br />CONSTRUCTION, <br />3. EXISTING FURNITURE, DECORATIVE LIGHTING, & EQUIPMENT NOT TO BE RE -USED. CONTRACTOR TO <br />BE RESPONSIBLE FOR SALVAGING FOR RECYCLING OR DISPOSAL AS REQUIRED. <br />4. REFER TO THE REFLECTED CEILING PLANS FOR ADDITIONAL DEMO NOTES SPECIFIC TO THE EXISTING <br />CEILING CONDITIONS. <br />5. CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL OF ANY AND ALL MATERIALS REFERRED TO <br />IN THE MED-TOX 2007 HAZARDOUS BUILDING MATERIALS SURVEY. SHOULD THE CONTRACTOR <br />ENCOUNTER ANY ADDITIONAL ASBESTOS MATERIALS, PCB'S, OR OTHER TOXIC SUBSTANCES NOT <br />NOTED IN THE SURVEY, THE CONTRACTOR SHOULD IMMEDIATELY REPORT THE FINDINGS IN WRITING <br />TO THE BUILDING OWNER & TENANT, PRIOR TO CONTINUING WITH ANY WORK IN THE AREA. WORK <br />SHALL NOT BE RESUMED EXCEPT BY WRITTEN AUTHORIZATION OR AGREEMENT FROM THE OWNER. <br />6. EXISTING HVAC EQUIPMENT, PLUMBING, DRAIN & FIRE PROTECTION LINES TO BE DEMOLISHED <br />EXCEPT AS NOTED, REFER TO MECHANICAL AND PLUMBING DEMOLITION DRAWINGS FOR FULL <br />EXTENT OF DEMO. CONTRACTOR SHALL VERIFY EXISTING ITEMS TO REMAIN WITH <br />ARCHITECT/MECHANICAL DESIGNER. COORDINATE WITH PROPERTY PRIOR TO INTERFERING WITH <br />EXISTING UTILITIES. <br />7. THE PLANS/ELEVATIONS ARE DERIVED FROM ARCHIVAL BUILDING PLANS & ARE INTENDED TO <br />REASONABLY REPRESENT EXISTING CONDITIONS, ACTUAL CONDITIONS MAY DEVIATE FROM THAT <br />SHOWN ON THE DRAWINGS. THE DEMO NOTES IDENTIFY SPECIFIC AREAS OF WORK, BUT MAY NOT BE <br />COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS, THE CONTRACTOR SHALL VERIFY ACTUAL <br />CONDITIONS & COORDINATE DEMO WITH NEW WORK SO THAT DEMO IS COMPLETE. <br />8. EXISTING LIGHT FIXTURES AND ELECTRICAL COMPONENTS TO BE REMOVED EXCEPT AS NOTED. <br />REFER TO ELECTRICAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION AND FIXTURES BEING <br />REMOVED. <br />9, EXISTING FINISHES WILL BE REMOVED IN THEIR ENTIRETY WHERE INDICATED AND EXPOSED <br />SURFACES PREPARED FOR NEW FINISHES. <br />10, ALL WORK WHICH IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AND, IF DAMAGED, SHALL BE <br />REPAIRED AT NO COST TO THE OWNER, PROVIDE DUST ISOLATION & PROTECTION TO LIMIT DUST TO <br />AREAS OF WORK. <br />T.®__PARAPET.__ <br />599' - 10" <br />DEMOLITION <br />584' 3 <br />f' / ;' AREA OF DEMOLITION <br />_(Q_LEVEL 01 <br />570 - <br />WALLS TO REMAIN <br />_ — - ITEM TO BE REMOVED <br />ITEM TO REMAIN <br />- ALIGN TOP OF CONCRETE <br />SAWCUTS W/ TOP OF EXISTING <br />WINDOWS AT LEVEL 2, TYP. <br />599'-10„ <br />T O.. ROOF_- <br />96' l <br />(E) LVEI_2 -.- <br />E) LEVEL 01 <br />670' - a„ <br />CONCRETE CUTS AT LEVEL 1, <br />NORTH ELEVATION, TO ALLOW FOR <br />TALLER OPENINGS AS SHOWN, <br />a: <br />0` 8' 16' 32' <br />"m6ill <br />P==19 <br />Otak " � "_` va <br />hitects, Inc. <br />0 w ird Avlpue, st-S A-00 <br />Poani% OR 97204 <br />5 207,6 2 <br />WWS. nOta xorfl <br />4� gg <br />STAMP <br />CONSULTANT <br />TITLE <br />9 DATE DESCRII <br />REVISIONS <br />'TION <br />EE, DP MS <br />)PAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />'STATUS <br />)4/17/2020 <br />)ATE <br />0801 <br />?ROJECT NUMBER <br />D2mOl <br />O 2020 OTAK, INC. <br />f this drawing is not 24" x 36", it has ,been <br />educedlenlarged. Scale accordingly. <br />