Laserfiche WebLink
m <br />SCALE: 1/16" = V-0" <br />BUILDINGL TE Otak <br />VA: �P: <br />1. ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF SLAB, <br />CENTERLINE OF COLUMN, CENTERLINE OF OPENING, AND TO <br />FACE OF EXISTING FINISH WHERE REMAINING, UNLESS NOTED <br />OTHERWISE. DIMENSIONS TO EXISTING REFERENCES SHALL BE <br />VERIFIED IN FIELD AND THE ARCHITECT NOTIFIED OF ANY Ot. is, Inca <br />DISCREPANCIES, UB S �' , Ir . ' ue. Sta 800 <br />Portia ``` -OR 97204 <br />2. GRID LINES INDICATE FACE OF EXISTING CONCRETE TILT -UP 5 .287.682 <br />PANEL AND CENTERLINE OF COLUMNS. otak m <br />3. SIDEWALKS AND PATIOS SHALL SLOPE AT 2% MAXIMUM AS y <br />SHOWN ON PLANS, WARP CONCRETE AT WALLS S AND COLUMNS <br />AS SHOWN TO FORCE WATER TO MIGRATE AWAY FROM AND <br />AROUND WITHOUT EXCEEDING 1.5% MAXIMUM SLOPE, <br />-C <br />4 4 <br />SEE SHEET A1.01 FOR TYPICAL CONSTRUCTION ASSEMBLY l< i <br />DESCRIPTIONS.. <br />5, SEE SHEET A8.14 FOR FIRE -RATED ASSEMBLY INTERSECTION�I# al <br />DETAILS. TAT � x�. <br />6. SEE SHEET A1.11 FOR DOOR TYPES AND SCHEDULE. <br />7. SEE EXTERIOR ELEVATIONS FOR EXTERIOR WINDOW 0 /20/2 20 <br />DESIGNATIONS AND SHEET A1.12 FOR GLAZING TYPES. STAMP <br />8. INDICATES INTERIOR RELITE. REFER TO SHEET Al A 2 FOR <br />ELEVATION AND WIDTHS. <br />9, SEE INTERIORS SHEETS FOR FINISH PLANS AND ROOM FINISH <br />SCHEDULES. <br />10. OPERABLE PARTS OF LIGHTING, ENVIRONMENTAL, ELECTRICAL, <br />SECURITY CONTROLS, AND ELECTRICAL RECEPTACLES SHALL <br />BE MOUNTED BETWEEN 15" AND 48" ABOVE FINISHED FLOOR. <br />SEE SHEET G3.01 FOR ADDITIONAL TYPICAL ACCESSIBLE <br />REQUIREMENTS. <br />11. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY USE SHALL CONSULTANT <br />HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED <br />IN A CONSPICUOUS PLACE. <br />12, ROOMS CONTAINING FIRE PROTECTION SYSTEMS OR <br />EQUIPMENT SHALL BE IDENTIFIED IN AN APPROVED MANNER. <br />SIGNS SHALL BE CONSTRUCTED OF DURABLE MATERIALS, <br />PERMANENTLY INSTALLED AND READILY VISIBLE. DOORS INTO <br />ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL <br />ROOM". <br />13. FINISHED FACE OF NEW WALLS TO ALIGN WITH EXISTING WALL <br />FACE WHERE INDICATED, FINISH TO BE FLUSH WITH AND MATCH <br />EXISTING ADJACENT WALL FINISH WHERE WALLS ABUT. <br />FLOOR PLAN LEGEND <br />EXISTING WALL <br />1-HR RATED WALL <br />=— FEC= FIRE :EXTINGUISHER 0 <br />CABINET <br />- - - - - - FLOOR OPENING + <br />SKYLIGHT ABOVE <br />uj <br />0 <br />0 0 q <br />Lu <br />0 < > <br />1 A3.02 <br />TITLE - <br />2 <A3.02 <br /># DATE DESCRIPTION <br />A 04/17/2020 PLAN REVISIONS <br />C 05/20/2020 PLAN REVISIONS <br />REVISIONS <br />KE MS <br />DRAWN BY CHECK BY <br />1.00% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />- _ ti.s' <br />A2ffl01 <br />0' 8' 16' 32' Q 2020 OTAK, INC. <br />alb <br />°� if this drawing is not24°x 36 it has been <br />reducedlenlarged. Scale accordingly. <br />