CL <br />6 <br />0 <br />co <br />a <br />�a <br />C <br />E <br />b <br />SEE 1/2.02a <br />MATCHLINE <br />,LEVEL 02 - FLOOR PLAN, - I <br />SCALE: 1/8" = V-0" <br />NEW SHEAR WALL <br />A <br />SEE 1/2.02a <br />MATCHLINE <br />B <br />�A6.02 ®� o <br />G <br />BUILDING PLAN NOTES <br />1. ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF SLAB, <br />CENTERLINE OF COLUMN, CENTERLINE OF OPENING, AND TO <br />FACE OF EXISTING FINISH WHERE REMAINING, UNLESS NOTED <br />OTHERWISE. DIMENSIONS TO EXISTING REFERENCES SHALL BE <br />VERIFIED IN FIELD AND THE ARCHITECT NOTIFIED OF ANY <br />DISCREPANCIES. <br />2, GRID LINES INDICATE FACE OF EXISTING CONCRETE TILT -UP <br />PANEL AND CENTERLINE OF COLUMNS. <br />3. SIDEWALKS AND PATIOS SHALL SLOPE AT 2% MAXIMUM AS <br />SHOWN ON PLANS. WARP CONCRETE AT WALLS AND COLUMNS <br />AS SHOWN TO FORCE WATER TO MIGRATE AWAY FROM AND <br />AROUND WITHOUT EXCEEDING 1.5% MAXIMUM SLOPE. <br />4. SEE SHEET A1.01 FOR TYPICAL CONSTRUCTION ASSEMBLY <br />DESCRIPTIONS. <br />5, SEE SHEET A8.14 FOR FIRE -RATED ASSEMBLY INTERSECTION <br />DETAILS. <br />6. SEE SHEET A1.11 FOR DOOR TYPES AND SCHEDULE. <br />7, SEE EXTERIOR ELEVATIONS FOR EXTERIOR WINDOW <br />DESIGNATIONS AND SHEET A1.12 FOR GLAZING TYPES. <br />8. INDICATES INTERIOR RELITE. REFER TO SHEET A1.12 FOR <br />ELEVATION AND WIDTHS. <br />9. SEE INTERIORS SHEETS FOR FINISH PLANS AND ROOM FINISH <br />SCHEDULES, <br />10. OPERABLE PARTS OF LIGHTING, ENVIRONMENTAL, ELECTRICAL, <br />SECURITY CONTROLS, AND ELECTRICAL RECEPTACLES SHALL <br />BE MOUNTED BETWEEN 15" AND 48" ABOVE FINISHED FLOOR. <br />SEE SHEET G3.01 FOR ADDITIONAL TYPICAL ACCESSIBLE <br />REQUIREMENTS. <br />11. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY USE SHALL <br />HAVE THE OCCUPANT LOAD OF THE DOOM OR SPACE POSTED <br />IN A CONSPICUOUS PLACE, <br />12. ROOMS CONTAINING FIRE PROTECTION SYSTEMS OR <br />EQUIPMENT SHALL BE IDENTIFIED IN AN APPROVED MANNER, <br />SIGNS SHALL BE CONSTRUCTED OF DURABLE MATERIALS, <br />PERMANENTLY INSTALLED AND READILY VISIBLE. DOORS INTO <br />ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL <br />ROOM". <br />13. FINISHED FACE OF NEW WALLS TO ALIGN WITH EXISTING WALL <br />FACE WHERE INDICATED, FINISH TO BE FLUSH WITH AND MATCH <br />EXISTING ADJACENT WALL FINISH WHERE WALLS ABUT. <br />EXISTING WALL <br />_�--_ 1-HR RATED WALL <br />FIRE EXTINGUISHER <br />CABINET <br />- - - - - - - FLOOR OPENING <br />SKYLIGHT ABOVE <br />112 NEW PARTIAL HEIGHT WALL WHERE GUARD AND/OR <br />HANDRAIL WAS REMOVED, PROVIDE 3/4" WHITE OAK TOP PER <br />DETAIL 7/A8.12. TOP OF WALL TO BE 42" A.F.F. OR LEADING <br />EDGE OF STAIR TREAD, <br />113 NEW 1-1/4" METAL PIPE HANDRAIL 36" ABOVE STAIR NOSING. <br />114 INSTALL 5/8" PLYWOOD BACKER BOARD OVER GYP BOARD <br />TO 8` A.F.F. AT WALLS INDICATED, PAINT TO MATCH WALLS <br />PER FINISH SCHEDULE. <br />117 TAPER GYP-CRETE TO MATCH EXISTING FLOOR LEVEL AT <br />STAIR LANDING. <br />118 NEW PONY WALL, HEIGHT AT 42" A.F,F. <br />122 INFILL TO MATCH EXISTING SURROUNDING WALL <br />CONSTRUCTION, INSTALL ADDITIONAL FRAMING, INSULATION, <br />AND GYP BOARD PER WALL ASSEMBLY INDICATED. FINISH <br />SMOOTH AND CONSISTENT WITH ADJACENT SURFACES. <br />128 3/4" GYPSUM CONCRETE OVER 1/2" ACOUSTICAL MAT <br />UNDERLAYMENT ON (E) PLYWOOD SHEATHING, TYPICAL AT <br />LEVEL 2. PATCH AND REPAIR SUBFLOORS TO LIKE <br />CONDITION PRIOR TO PLACING GYPCRETE. A <br />LEVEL 02-A <br />5 <br />11I1 � <br />, i p <br />W� <br />t K, hitraC s, inc, <br />orflane OR 97204 <br />if <br />7.29.2020 <br />STAMP <br />CONSULTANT <br />0 <br />Fism <br />0 <br />uj <br />0 <br />jy <br />CA <br />0 <br />z <br />> <br />CN W <br />TITLE <br />A DATE DESCRIPTION <br />A 04/17/2020 PLAN REVISIONS <br />B 05/20/2020 PERMIT REVIEW 1 <br />E 07/29/2020 PERMIT REVIEW 2 <br />REVISIONS <br />KE, CD, DP MS, JG _ <br />DRAWN BY CHECK BY - <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />