Laserfiche WebLink
Ei <br />LO <br />0 <br />0 <br />CN <br />i <br />I <br />�6.O SCALE: 1/4" = 1' 0" <br />A <br />TILE, TYP. S <br />INTERIORS <br />5A 5B <br />2A <br />SCALE: 1/4" = V-0" <br />gTILE <br />Fr) ! Pr) <br />TILE TO CEILING AT <br />TOILET WALL, TYP <br />2" MIN <br />16"-18" <br />UNISEX <br />NSI X 01 INTERIOR ELEVATIONS, <br />SCALE: 1/4" = V-0" <br />TILE, TYP. SEE <br />INTERIORS <br />IF <br />bn <br />Bill 911 <br />z <br />I <br />— TILE, TYP. SEE <br />INTERIORS <br />2" MAX <br />TILE TO <br />CEILING AT <br />TOILET WALL, <br />TYP. - <br />MAX <br />era <br />TILE, TYP. SEE <br />INTERIORS <br />WING WALL, TYP. <br />TILE TO <br />CEILING AT <br />TOILET WALL, <br />TYP <br />MIN <br />1/2 TILE AT <br />BASE, TYP <br />REF. INTERIOR <br />FINISH SCHEDULE <br />FOR TILE, CENTER <br />JOINT PATTERN ON <br />WALL, TYP. <br />Rpm <br />gTILE <br />TILE TO CEILING AT <br />TOILET WALL, TYP <br />TILE, TYP, SEE <br />INTERIORS <br />C <br />L <br />1/2TILE AT BASE, <br />TYP <br />1/2TILE AT BASE, TYP <br />Ar, nA J SCALE: 1/4" = V-0" <br />ENLARGED PLAN NOTES <br />1, ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF SLAB, CENTERLINE OF <br />COLUMN, CENTERLINE OF OPENING, AND TO FACE OF EXISTING FINISH <br />WHERE REMAINING UNLESS NOTED OTHERWISE. <br />2. FOR ARCHITECTURAL ABBREVIATIONS & SYMBOLS LEGEND SEE SHEET <br />G0.01, <br />3. FOR CONSTRUCTION ASSEMBLY DESCRIPTIONS SEE SHEET A1.01. TYPICAL <br />NEW INTERIOR WALL STUDS ARE 3-5/8" STEEL STUDS UNLESS OTHERWISE <br />NOTED ON PLANS OR IN THE TAGGED ASSEMBLIES. VERIFY GRADE AND <br />SPACING WITH STRUCTURAL. <br />4. SEE SHEETS A1.11 AND A1.12 FOR DOOR AND WINDOW TYPES AND <br />SCHEDULES. REFER TO INTERIOR SHEETS FOR ROOM FINISH SCHEDULES <br />AND FURNISHINGS. <br />5. SEE SHEET A8.14 FOR FIRE RATED WALL INTERSECTIONS. <br />6. CONCRETE PATIOS SHALL SLOPE AT 2%a MAXIMUM AS SHOWN ON PLANS. <br />WARP CONCRETE AT WALLS AS SHOWN TO FORCE WATER TO MIGRATE <br />AWAY FROM AND AROUND WITHOUT EXCEEDING 1.5%MAXIMUM SLOPE. <br />7. LIGHT SWITCHES, ENVIRONMENTAL CONTROLS, AND OTHER CONTROLS <br />SHALL BE 48` HIGH MAXIMUM ABOVE FINISH FLOOR. ELECTRICAL, <br />TELECOMMUNICATIONS (TELEPHONE/TELEVISION) OUTLETS RECEPTACLE <br />ON WALLS SHALL BE MOUNTED BETWEEN 15' AND 48" ABOVE FINISHED <br />FLOOR. <br />8. SEE DETAIL SHEET A8.14 FOR INFORMATION REGARDING JUNCTION BOX <br />PLACEMENT. <br />9. SEE SHEET A8,12 FOR TYPICAL INTERIOR DOOR FRAME AND RELITE HEAD <br />AND JAMB DETAILS. <br />10, SEE SHEETS A6.02 AND A6.03 FOR STAIR PLANS AND SECTIONS, REFER TO <br />SHEET A8.11 FOR STAIR, GUARDRAIL, AND HANDRAIL DETAILS. <br />11. ALL FAUCETS TO HAVE LEVER HANDLES. <br />12. SEE ELEVATIONS FOR ALL VENT LOCATIONS, MECHANICAL TO COORDINATE <br />LOCATIONS OF VENTS AND SOFFITS WI LOCATIONS SHOWN ON PLANS AND <br />ELEVATIONS. ALL VENTS TO BE GREATER THAN 3-0" FROM ALL OPERABLE <br />OPENINGS, <br />13. FOR MECHANICAL SYSTEMS & EQUIPMENT SEE MECHANICAL BUILDING <br />DRAWINGS, <br />I <br />140 BABY CHANGING STATION <br />141 COMBINATION TOILET TISSUE AND SEAT COVER DISPENSER <br />142 COMBINATION TOILET TISSUE DIESPENSER, SEAT COVER <br />DISPENSER, AND SANITARY NAPKIN DISPOSAL <br />143 COMBINATION PAPER TOWEL DISPENSER AND WASTE RECEPTACLE <br />144 SOAP DISPENSER <br />145 NAPKIN/TAMPON VENDOR <br />147 SHELF WITH MOP AND BROOM HOLDERS <br />SEE INTERIOR <br />SHEETS FOR <br />FLOOR TILE <br />DIRECTION, TYP. <br />itav 113rtects, Inc. <br />BDS SW filrd Av us sts 800 <br />nd <br />HI OR 97204 <br />r <br />` �.287.682 <br />vvr OU*xonl <br />�`d s <br />ga A. <br />ss <br />�. I �111, <br />0 / 0/2020 <br />g M&F'' <br />CONSULTANT <br />0 <br />it0 <br />uj <br />0 <br /><g <br />Ce <br />0 <br />00) <br />< <br />co <br />W <br />TITLE <br />#fi DATE DESCRI <br />A 04/17/2020 PLAN RE' <br />B 05/20/2020 PERMIT f <br />?TION <br />ASIONS <br />IEVI EW 1 <br />REVISIONS <br />DP MS <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />meffixIM111A11M:1 <br />0 2020 OTAK, INC. <br />If this drawing is not 24" x 38", it has been <br />reducedlenlarged. Scale accordingly. <br />