• 10
<br /> Page 4 of 4 July 22, 2020
<br /> M2200713 Asbesto-Test,Inc. 425-489-4040
<br /> Carport Only(a, 712 33rd St.,Everett, WA 98201
<br /> Y c .,,' z
<br /> •
<br /> i _ -
<br /> r. -3 s,'
<br /> a , -
<br /> ,0_
<br /> s
<br /> - _ ,
<br /> R ro 'Twl Peaks
<br /> k 41F1 l
<br /> - w . i' '3 ":-.,h-9 T-.4
<br /> - 4 F( '0. „--hi l 1, '8 A � ,"
<br /> �� 43 3Y - ;�� 7. _. _fir
<br /> r B ' " ' y,}
<br /> kit
<br /> '' &.r'f. :.%. -�' +F.eV '' .4 t ,p Y t M,
<br /> s, Fs T .. t r'' .Zr' •� � r i^L�'44„.-k .am ��,-l � �T ,: "` , k `�
<br /> R
<br /> t,��l�a:. 9 -n ots"^ . ,r o,.r,a�dx," �' d B_ - atilf ,_x,.�.� ..`1'
<br /> If,during demolition or renovation,any additional hidden or covered suspect materials similar to those identified in the survey are located[may include but not limited to:sheet
<br /> vinyl flooring,tile flooring,wall or ceiling texturings or paints,concrete siding or skirting,cement pipes,cement wallboard,electrical doth,electrical wiring insulation,thermal
<br /> paper,wallboard,joint compounds,vinyl wall coverings,spackling compounds,or any other suspect TS!(Thermal System Insulation)),they are presumed Asbestos Containing
<br /> Materials unless determined to be non-asbestos by laboratory analysis
<br /> Asbesto-Test Inc does not guarantee approximations of quantities of ACM,which may be listed with the analyses.It is therefore recommended professional abatement price
<br /> and/or disposal quotes be obtained by inquiring as to fees per area of specific ACM material(i.e.square or linear foot,etc.),or by on site assessment.
<br /> Any and all materials identified as ACM and/or PACM in this report must be abated prior to disturbance in renovation or demolition.
<br /> Analytical test method:USEPA 600/R93/116"(PLM);WAC 296-62-07753 App.J
<br /> "One percent is the USEPA regulatory limit for asbestos in bulk samples.
<br /> Key: "FRIABLE'signifies"Easily Airborne"
<br /> ACM signifies Asbestos Containing Material"
<br /> PACM signifies"Presumed Asbestos Containing Material"
<br /> CAB signifies"Concrete Asbestos Board'
<br /> < signifies"less than"
<br /> 751 signifies"Thermal System Insulation"
<br /> HVAC signifies"Heating Ventilating Air-Conditioning"
<br /> HAD signifies"No Asbestos Detected"
<br /> END OF REPORT
<br /> ArLynn Hammond, Pres., BSc.
<br /> Analytical Chemist, AIHA proficient
<br /> Inspector, certified A.H.E.R.A.
<br /> accred#178488; exp. July 15,2021
<br /> Lit
<br /> 0 ,_,
<br /> 1429 Ave.D.#I87,Snohomish,WA 98290
<br /> 425-4894040:f 775-665-0420
<br /> ,,.0 u nchectntnct cnm inti,(iinchtnctnmct,-nm
<br />
|