Laserfiche WebLink
Residential Plumbing Sewer and Drainage Investigation <br /> Site Address: <br /> 1415 Rucker <br /> Everett WA 98201 <br /> 10/08/13 <br /> • <br /> .x . <br /> r . <br /> 14 . <br /> I S. rk <br /> • ~ F 1111 <br /> F .c <br /> Plumbing and Drainage Inspector: <br /> Steve's Plumbing LLC <br /> 19707 64th Ave W,#108 <br /> Lynnwood,WA 98036 <br /> House Specifics: <br /> • House currently has a backwater valve on side sewer?NO <br /> • How many open plumbing fixtures are in the house below the elevation of the adjacent road <br /> surface?5 <br /> • House has downspouts connected to side sewer?YES <br /> • Does Side Sewer have grade?YES <br /> • Approximate depth of side sewer: 5' <br /> • Depth and Location of proposed Backwater Valve: 20' away from house or closer at an <br /> approximate depth of 5',disconnecting the downspout tie-in at the same time <br /> • Additional Comments: Private side sewer has several breaks in it. <br /> Plumbing, Sewer, or Drainage Problems Identified: <br /> 1)House is not protected from sewer surcharge event. <br /> Suggested Solution: install backwater valve 20' away from house or closer at an approximate depth of 5' <br /> 2) Site Drainage: Small channel drain across basement door that goes to a sump pump which pumps to a <br /> floor drain and then on into the sewer system. <br /> Suggested Solution: <br /> A. Sump pump would need to be re-directed. During a storm if a backwater valve was installed and <br /> it closed the sump pump would pump surface water into the basement through the floor drain it is <br /> attached to. <br />