Laserfiche WebLink
r A <br /> Residential Plumbing Sewer and Drainage Investigation <br /> . J .?...:: - _._. ---.��il r - *--4ir 41/0-, <br /> 1 <br /> o <br /> M ' <br /> a i. <br /> �11r - pY v <br /> '�iys� a� � • <br /> Site Address: <br /> 1511 Rucker Ave <br /> Everett,WA 98201 <br /> 9/17/13 <br /> Plumbing and Drainage Inspector: <br /> Steve's Plumbing LLC <br /> 19707 64th Ave W,#108 <br /> Lynnwood,WA 98036 <br /> House Specifics: <br /> • House currently has a backwater valve on side sewer?NO <br /> • How many open plumbing fixtures are in the house below the elevation of the adjacent road <br /> surface?Floor drain, shower and tub <br /> • House has downspouts connected to side sewer?Yes, 3 <br /> • Does Side Sewer have grade?YES <br /> • Approximate depth of side sewer: 1'6" <br /> • Depth and Location of proposed Backwater Valve: No recommended depth <br /> • Additional Comments None <br /> Plumbing,Sewer,or Drainage Problems Identified: <br /> 1)Basement fixtures are not protected from a surcharge event <br /> Suggested Solution: Install Backwater Valve in concrete pad area near alley way. This will require the 3 <br /> remaining down spouts to be disconnected from the side sewer. <br /> 2)Roof Drainage: Total of 7, 3 going to sewer,2 go to French drains and 2 are splash blocks(hoses) <br /> Suggested Solution: Disconnect down spouts from sewer <br />