Laserfiche WebLink
BACKWATER PREVE�VTION DEVICE FINAL <br /> INSTALLATION CHECKLIST <br /> Installalion Company Name and Contaot Info:A+ S�wer TPchnologie5l 1 C (A88-213-76 61 � <br /> Date backwater device(BWD)was inslalled:_ Date Ihis form was completed: <br /> Instalialion Property Owner Name and Contact Info: Chuck Steinberner 425 239•4346 <br /> Property Address: 1528 Rucker Ave Everett WA 98201 <br /> Pre•Installation Inspection Checklist: <br /> All items must 6e checked 'Yes'in order tor a BWD lo be considered for installation <br /> Is there a basement or level of the house Ihal is at or near assumed sewer main elevation?[�Yes ❑ No <br /> Are Ihere fixtures in ihe house located below the upslream sewer manhole rim elevalion?�Yes ❑No <br /> Is ihe side sewer currently UNPROTECTED from se�ver backups(does not have a BWD installed)?❑✓ Yes ❑No <br /> Site Inspecfion Checklist: <br /> All ifems must 6e checked 'Yes'before inspeclion is considered complete <br /> Was side sewer TV inspected from building to sewer main? Q✓ Yes ❑ No Condition: <br /> Does side sewer have at least i%slope from Ihe building to sewer main? ❑� Yes ❑No Descnbe: <br /> Have all building sewer drain connections to th�side sewer been idenlified and located? Q✓ Yes ❑ No <br /> Have all property siorm drainage connecfions lo the side sewer been idenii6ed and located? []Yes ❑No <br /> Has property been evaluated(or drainage deficiencies with findings communicated to properfy owne� �]Yes ❑ No <br /> Installation Details: <br /> What type and brand of BWD was installed al lhis sile(Clean Check BWV,Grinder pump,etc.): Clean Check HWV <br /> Where was lhe device inslalled(generai descriplion, aUach map)? See attached as huilt <br /> Was there any olher sewer or storm drainage work compleled in conjunclion with Ihe ABWD work?Is so please describe: <br /> Installation Checklist: <br /> Are all downspouts and site drainag�disconnecled(rom upstream o(the DWD? ❑Yes �✓ No CommeNs: <br /> Does BWV posilioning meet minimum slope requiremenl of>1"/e 1 [�Yes ❑No Comments: <br /> Can DWV be pulletl out for inspection and mainlenance aiter Ioosening thumb screw? ✓❑Yes ❑ No <br /> Is BWV locked iNo Ihe proper position and thumb screw lighlened? U Yes ❑No <br /> Circle ihe 4WV cover,irrigalion cover (landscape area)I IraKc load hearing cover(drive surface)1 access hatch f building) <br /> Was homeowncr shown Ihe localion oF Ihe inslalled ABWD? ❑✓ Yes ❑Nn Commenis: <br /> /� � <br /> Pwperiy Owner's Signalure: Ci/�f �;f�� p,31P; li �'l S� <br /> inslaller's 5ignalure: Walt "`� '�'X'�/��/i <br /> . �,,.,,M,mn;'� Dafe: � ,��-��/� <br /> Rev(sion: 2 1 Thursday,October 02,2074 <br />