Laserfiche WebLink
House Specifications & work Recommended <br />Site Draina�e Recommendations: <br />No site Drainage Appears to be tied into sewer <br />Roof Drain Dischar�e Recommendations: <br />8 downspouts 1 to ground 7 appear to be tiec into French drain <br />Internal Plumbin�: <br />Backwater valve ins located in downstairs bedroom 8" off of N wall and <br />11.5' off of west wall backwater valve is not accessible and does not <br />work rE�commend removing existing back water valve to prevent future <br />issues and installing a new one outside of house where sewer exits. <br />Existing cast iron in crawl shows signs of age and is falling apart line fell <br />aNart in crawl when inspecting line with camera repaired faulty section <br />of pipe. Downstairs toilet and shower are point of entry for surge. <br />Side Sewer Recommendations: <br />Private sewer is approx 60' to city main line is existing concrete and <br />should be relined to prevent future backups <br />Sewer should have a backwater valve installed on outside of home to <br />preventfuture backups <br />2;� <br />