Laserfiche WebLink
Is backwater valve functioning properly: NA <br /> Is there currently a clean out on the side sewer: Yes interior and buried outside of <br /> home. <br /> How many down spouts on premises: 4 <br /> How many down spouts are connected to sewer: None, they are tied into a <br /> downspout/footing drain system that ties into a catch basin system that drains to sewer. <br /> Sewer Report: <br /> Camera Access: Basement Cleanout behind laundry <br /> Material: PVC customer side, clay city side. <br /> Depth of side sewer exiting house: 4'10" <br /> Depth at city sewer main: 8'4" <br /> Does side sewer have slope: Yes on customer side, city side has problems and a <br /> Service Request has been opened. City side is missing portions of clay pipe and has <br /> standing water in spots and needs repair. <br /> t. _ ,____...„ , ,, <br /> yyAN,yt <br /> , <br /> *' F <br /> te a- ii z-`V ��' t 4Y- sue i _ <br /> ' .. t'-14 r1 .'..y1i A-cam, <br /> 41 <br /> LLti -I a bF Y ;j -' _ _...-.�_A <br /> This is the location of problem city side sewer, just south of tree marked with white <br /> paint. <br /> 0. lC <br />