Laserfiche WebLink
Does side sewer have slope: Yes, 2% <br /> Depth of side sewer 10ft from house: 6 feet <br /> Any additional comments: <br /> • It was not possible to open clean out. Inspection used toilet in basement for <br /> access to the side sewer. The pipe was previously remodeled with a series of <br /> bends making it impossible to fully reach city sewer system. The side sewer <br /> camera inspection made it to the sidewalk. <br /> Problems Identified <br /> 1) This home does not currently have a backwater valve to prevent backups during high <br /> flow surcharge events. <br /> Solution: <br /> Install backwater valve upstream of all downspout and exterior drain connections. See <br /> attached site drainage and plumbing sketch for proposed location. <br /> 2) Down spouts on north side of house are not discharging water far enough from the <br /> house foundation. <br /> ‘t,,,, <br /> f' <br /> • <br /> r•� .N.1 a ,fit 1 --/ gyp_ �. 4 i�i.A`-4 r <br /> . • - crIT-0 <br /> Solution A: Extend downspout piping away from house and provide a splash block a <br /> minimum of 3 feet from the house. <br /> S:\#Common\clerical\SIDE SEWER&PLUMBING INVESTIGATION\Final Reports\2nd Batch\732 wetmore final.docx 5/3/2011 <br />