Laserfiche WebLink
I <br />c <br />a <br />c <br />`c <br />27'-0" <br />1 14'-0" 1 6-4" _ I _ 13'-8" --- --- -1 <br />SCALE: 1/4" = V-0" <br />EGRESS <br />AREA SUMMARY <br />5.7 SQ FT MIN OPENABLE AREA <br />UPPER FLOOR 1435 SQ. FT. <br />20 MIN. OPENABLE WIDTH <br />LOWER FLOOR 797 SQ. FT. <br />24 MIN. LE HEIGHT <br />TOTAL HEATED AREA 2232 SQ. FT. <br />N. FLOOR <br />44 MAX ABOVE FIN. <br />GARAGE 594 SQ. FT. <br />GLAZING SUMMARY <br />GLAZING <br />TOTAL GLAZING AREA 245.0 SQ. FT, <br />GLAZING AREA (% OF FLOOR) 9.3% <br />U-FACTORS (VERTICAL GLAZING/DOORS 0.28 <br />GLAZING: (245 / 2232 = 10.9%) <br />U-FACTORS (OVERHEAD GLAZING) 0.50 <br />INSULATION VALUES <br />WASHINGTON STATE ENERGY CODE REQUIREMENTS^� <br />VAULTED CEILINGS: R-38 BATT (500 SQ FT MAX.) <br />SEC 401.3 POST ENERGY CODE COMPLIANCE CERTIFICATE WITHIN <br />VAULTED SCISSOR: R-49 BATT OR BLOWN <br />3 FT OF ELECTRICAL PANEL AVAILABLE AT <br />FLAT CEILINGS: R-49 BATT OR BLOWN <br />WWW.ENERGY.WSU.EDU/CODE. <br />EXTERIOR WALLS: R-21 BATT <br />SEC 402.4.1 PROVIDE DOOR BLOWER TEST AFFIDAVIT BY FINAL <br />FLOOR w/ CRAWLSPACE: R-38 BATT <br />BUILDING INSPECTION <br />SLAB ON GRADE: R-10 RIGID PERIMETER <br />SEC 403 1 1 PROVIDE 1 PROGRAMMABLE THERMOSTAT <br />SEC 403.2.2 PROVIDE DUCT SEALING AFFIDAVIT BY FINAL <br />INSPECTION <br />SEC 404.1 A MINIMUM OF 75% OF ALL PERMANENTLY INSTALLED <br />LIGHTING SHALL HAVE HIGH EFFICACY LIGHTING <br />FANS - BATHROOM 50 CFM MIN (UNO), VENT OUTSIDE <br />)KE ALARM AND <br />IONOXIDE ALARM. <br />ARMS AND <br />ONOXIDE <br />HOULD BE <br />NECTED, <br />:D, AND BE <br />WITH A BATTERY <br />"v» <br />0 <br />r <br />c <br />INTERIOR SQ FOOTAGE <br />LOWER 797 <br />UPPER 1435 (INCLUDES BONUS ROOM) <br />TOTAL 2232 SQ FT <br />KITCHENS 100 CFM <br />WHOLE HOUSE 97.5 CFM <br />PROVIDE WHOLE HOUSE EXHAUST, CONTINUOUS FAN, 4-5 BEDROOM, 1501-3000 SQ FT, 75 CFM AIRFLOW. <br />WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE <br />EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED <br />WITHIN 6' OF THE EXHAUST DUCT CONNECTION. <br />PROVIDE A 4 SQ IN FRESH AIR INLET TO EACH LIVING AREA. <br />T-0" 13'-0" 7'-0" <br />4 <br />3'-5y2" 9'-4" 2'-11y2" 11'-8" I 6'-7" <br />12'-9y2' 21'-2Y2" <br />WINDOWUL <br />ID <br />SIZE <br />AREA <br />1 <br />4040 <br />16.0 SQ. FT. <br />2 <br />4040 <br />16.0 SQ. FT. <br />3 <br />4040 <br />16.0 SQ. FT. <br />4 <br />5040 <br />20.0 SQ. FT. <br />5 <br />4020 <br />8.0 SQ. FT. <br />6 <br />4026 <br />10.0 SQ. FT. <br />7 <br />2040 <br />8.0 SQ. FT. <br />8 <br />5040 <br />20.0 SQ. FT. <br />9 <br />2040 <br />8.0 SQ. FT. <br />10 <br />4040 <br />16.0 SQ. FT. <br />11 <br />4040 <br />16.0 SQ. FT. <br />12 <br />2030 <br />6.0 SQ. FT. <br />13 <br />2030 <br />6.0 SQ. FT, <br />14 <br />4030 <br />12.0 SQ. FT. <br />15 <br />1646 <br />6.75 SQ, FT. <br />16 <br />5040 <br />20.0 SQ. FT. <br />17 <br />4020 <br />16.0 SQ. FT. <br />18 <br />4040 <br />16.0 SQ. FT. <br />19 <br />2040 <br />8.0 SQ. FT. <br />TOTAL <br />244.75 SQ. FT. <br />UPPER FLOOR PLAN <br />SCALE: 1/4" = V-0" <br />WHOLE HOUSE FAN WITH A <br />TIMER RUNNING 66% 97.5 CFM <br />CONVERSION RATE 1.5 <br />PER TABLE 4 BEDROOM 2001-2500 <br />SQ FT 65 CFM. 65 (1.5) = 97.5. <br />3.0 AIR CHANGES PER HOUR <br />R-49 <br />INSULATION <br />ROOF TRUSS <br />PER FRAMING - <br />PLAN <br />5/8" <br />GWB H1 CLIP AT EACH TRUSS <br />TO DBL TOP PLATE / HEADER <br />OR BEAM CONNECTION <br />RIGID INSULATION <br />BEHIND HEADER (R-10) <br />0 2x6 STUDS <br />bo @ 16" O.C. <br />T&G APA 24/6 RATED <br />PLYWD SHEATHING GLUED <br />& NAILED TO FLOOR JOISTS <br />2x6 BASE PLATE <br />(NAILING PER SHEAR <br />WALL SCHEDULE) <br />JOISTS, VAPOR <br />PER PLAN BARRIER <br />2x6 BASE PLATE <br />�- (NAILING PER SHEAR <br />WALL SCHEDULE) <br />0 <br />Y4" T&G APA 24/6 RATED <br />PLYWD SHEATHING GLUED <br />& NAILED TO FLOOR JOISTS <br />z_ <br />FLOOR JOIST <br />PER PLAN <br />CRAWLSPACE GRADE <br />EQ. <br />%6" APA 24/6 RATED OSB <br />SHEATHING W/ 6d @ 6" O.C. <br />EDGE & 12" O.C. FIELD NAILING <br />(U.N.O. IN NOTES) <br />INSULATION <br />BAFFLE <br />R-21 INSULATION <br />V-0" <br />SHEAR WALL <br />PER PLAN <br />R21 <br />INSULATION <br />SHEAR WALL <br />PER PLAN <br />R-21 INSULATION <br />@ WALL <br />R-38 INSULATION OVER <br />UNHEATED SPACE <br />Z <br />2i <br />o z <br />Inn =0 T <br />4" PERFORATED <br />FOOTING DRAIN <br />8" EQ. SURROUND W/ GRAVEL <br />1'-4" <br />TYPICAL SECTION <br />SCALE: 3/4" = V-0" <br />U) <br />z <br />O <br />Ln <br />w <br />r <br />OO <br />Q. <br />U <br />W <br />W <br />O <br />❑ <br />U <br />W <br />N <br />cV <br />❑ <br />A <br />W <br />� <br />r <br />co <br />rn <br />ono F- <br />�W <br />co LlJ <br />N j <br />Q <br />U <br />Z <br />� <br />Z <br />O <br />O <br />:D lY <br />111 <br />r 00 <br />a) <br />U) � Z <br />w Li <br />W ® F- z <br />o�- <br />uV)w <br />rn <br />3-14-22 <br />S McC�9 >' <br />WAse�i, <br />p <br />cn <br />C1�38799��4 w� <br />RAL Er <br />�SjONAL <br />ECG <br />CN <br />CN <br />PLAN VIEWS <br />REVISION: <br />1 <br />DATE: <br />3-14-22 <br />DRAWN BY: <br />TJM <br />SCALE: <br />AS NOTED <br />PROJECT NO: <br />W4737 <br />SHEET NO: <br />