Laserfiche WebLink
-Tare Sct G 0�(-�,v����/e�w � Cre <br /> 9 Uq S e Evevdtt S ( (it)e, fie• L 5 Co • <br /> Evr v et, ct S- <br /> 206�Z`35�i��� <br /> Accessibility <br /> Bathroom <br /> The existing bathrooms which are mirror images of each other, fully comply with all <br /> accessibility regulation as follows <br /> • ". Handoperated flush controls shall comply with Section 309 of ICC A117.1, except <br /> the maximum height above the floor shall be 44 inches (1118 mm). Flush controls <br /> shall be located on the open side of the water closet"They are on open side of <br /> toilet at a heigh of 29 " <br /> • "The centerline of the water closet shall be 24 inches (610 mm) minimum and 26 <br /> inches (660 mm) maximum from one side of the required clearance" It is 25" <br /> • Clearance around a water closet shall be 66 inches (1675 mm) minimum in width, <br /> measured perpendicular from the side of the clearance that is 24 inches (610 mm) <br /> minimum and 26 inches (660 mm) maximum from the water closet centerline. It is <br /> 66" <br /> • Clearance around the water closet shall be 78 inches (1980 mm) minimum in depth, <br /> measured perpendicular from the rear wall. It is 74" <br /> • Seat height shall be 17-19 inches: It is 18 " <br /> • Wall mounted side and rear combination grab bars comply with ICC A117: <br /> height 34" 1.5 " space from wall, round cross section, 1.5" diameter, side <br /> length: 55" rear length 44" <br /> • Toilet paper dispenser at 29" height <br /> Egress <br /> All egress routes shall be at least 44"wide, they are 48" or wider <br /> 11)[ ©IOVI <br /> FEB 2 3 2022 <br /> CITY OF EVERETT <br /> Permit Services <br />