• <br /> The building will require an automatic NFPA-72 monitored fire alarm to be installed. <br /> Additional permits are required. IFC Section 907.1.4 (City of Everett Amendment) <br /> The referenced codes should be revised to the 2018 code editions. IBC Section 107.2.1 <br /> Egress <br /> The occupant load of each occupied room should be shown on the plans. IBC Section <br /> 107.2.3 <br /> The assembly occupancies will require at least two means of egress. IBC Section 1006.2.1 <br /> All doors serving the assembly spaces should be specifically shown to have panic hardware <br /> (from the rooms to the exterior exit doors). IBC Section 1010.1.10 <br /> 4 The new rear egress stairs should be a minimum of 44"clear in width. IBC Section 1011.2 <br /> X Guards should be shown for the lower portion of the new stairs. IBC Section 1011.13 <br /> Handrails (with extensions) should be shown on each side of each stairway. The design <br /> for the new stairs will need to be modified to allow for the handrail extensions. IBC <br /> Sections 1011.11 & 1014.6 <br /> All doors from the assembly spaces on the lower floor should swing in the direction of <br /> travel. IBC Section 1010.1.2.1 <br /> The landing at the bottom of the interior stairs should be a minimum of 44" deep. IBC <br /> Section 1010.1.6 <br /> The location and nomenclature of the maximum occupant load signs for the assembly <br /> spaces should be shown on the plans. Section 1004.9 <br /> Emergency egress lighting should be provided at the exterior landings at the exterior exit <br /> doorways as well as the exterior exit stairs. Section 1008.3.2, Item 5 <br /> A sign stating Exit in raised characters and braille and complying with ICC A117.1 should <br /> be shown adjacent to the exterior exit doorways. Section 1013.4 <br /> Accessibility <br /> An accessible route of travel (ingress and egress) should be shown for the enclosed deck <br /> addition. IEBC Section 305.5 <br /> Othe site plan should show the accessible parking as well as the accessible route from the <br /> parking to the accessible entrance. IEBC Section 305.4.2 <br /> 0 3200 Cedar Street G 425.257.8810 0 tlee@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />