Laserfiche WebLink
u; <br /> SITE PLAN NOTES: <br /> 1. THIS SITE PLAN REPRESENTS THE BESTA .._ <br /> ,_, <br /> PRESENT KNOWLEDGE AVAILABLE TO THE <br /> - ENGINEER AT THE TIME OF THIS DESIGN.THE /` <br /> CONTRACTOR SHALL VISIT THE SITE PRIOR (GRASS EXISTING WALL <br /> TO CONSTRUCTION AND VERIFY ALL --''--� <br /> SURFACE <br /> EXISTING CONDITIONS RELATED TO THE � AMERICANTOWER° <br /> SCOPE OF WORK FOR THIS PROJECT. <br /> 2. ICE BRIDGE,CABLE LADDER,COAX PORT, PP <br /> AND COAX CABLE ARE SHOWN FOR C Al <br /> REFERENCE ONLY. CONTRACTOR SHALL ( �FI� ; V1 <br /> CONFIRM THE EXACT LOCATION OF ALL C <br /> PROPOSED AND EXISTING EQUIPMENT AND PROPOSED 18'-0" <br /> STRUCTURES DEPICTED ON THIS PLAN. (2)HCS 2.0 TRUNKS )' — <br /> BEFORE UTILIZING EXISTING CABLE (ROUTED PER PROPOSED CABLE 3'-O" <br /> SUPPORTS,COAX PORTS,INSTALLING NEW LENGTH NOTE 2) GATE 7'-6" /— EXISTING 715'-6" MONOPOLE <br /> PORTS OR ANY OTHER EQUIPMENT, (REFER TO PROPOSED CABLE LENGTH / ice ' <br /> CONTRACTOR SHALL VERIFY ALL ASPECTS NOTE ON THIS PAGE) 1 EXISTING T-MOBILE EQUIPMENT ON jai <br /> OF THE SPECIFICAONS.COMPONENTS MEET THE ATC - —_ 3" X 14' EQUIPMENT PLATFORM �.�,y7 <br /> WITHIN 36 SO, FT GROUND SPACE ' <br /> _ 326 TRYON ROAD <br /> 3. THIS CONSTRUCTION DRAWING SET IS NOT I M RALEIGH,NC 27603 3530 <br /> ;X PROPOSED T-MOBILE EQUIPMENT <br /> INTENDED TO ADDRESS ANY ELECTRICAL 71^ / % 'I ; GE TO BE INSTALLED ON EXISTING OFFICE(919)661.6351 <br /> UPGRADES NEEDED.ANY ELECTRICAL <br /> UPGRADES WILL BE SHOWN IN A SEPARATE rl> / EQUIPMENT PAD,INSIDE <br /> CONSTRUCTION DRAWING SET. EXISTING ' ›y` — �J PROPOSED CABINETS: ww. p.net <br /> (6) 7/8" COAX CABLES —�- lj l (1)PURCELL HPL3 600A DC PLANT REV. DESCRIPTION BY DATE <br /> (TO REMAIN) ���,,` ,, 7\ 1 (1)PURCELL LB3 BATTERY CABINET <br /> LEGEND (6) 7/8" COAX CABLES = _ (2)HCS 2,0TOWER JUNCTION BOXES A PRELIMINARY SRZ 06/30121 <br /> (7) NSN LOW CAP HCS CABLE a (2)ASIKs 100%CONSTRUCTION SRZ d9/22121 <br /> (TO BE REMOVED) J �\ r (2)ASIBs <br /> 0 GROUNDING TEST WELL 7 +{-% , 4•< (6)BILs s ©�.�.y7 / \ <br /> ATS AUTOMATIC TRANSFER SWITCH ��'' (. - H,R (3)ABIAs A — <br /> B BOLLARD G( RAYEL 0 `F > (2)AMIAs _ <br /> CSC CELL SITE CABINET SURFACES r� � �i J (4)AMPLIFIERS <br /> D DISCONNECT f E.3 t t (1)VOLTAGE BOOSTER ATC SITE NUMBER: <br /> V (1)FRIE 83177 <br /> E ELECTRICAL - f^"' i (1)CSR IXRE V2 <br /> EXISTING 3' x 6' - <br /> F FIBER -;~-__7 1(---t- <br /> 7 • ATC SITE NAME: <br /> GEN GENERATOR EQUIPMENT PLATFORM -- <br /> G GENERATOR RECEPTACAL BY OTHERS ) M>'0 " © EXISTING TREE LINE (TYP.) PORT GARDNER <br /> HH,V HAND HOLE,VAULT /' �i <br /> IB ICE BRIDGE N I f` .r .,I ' T-MOBILE SITE NAME: <br /> K KENTROX BOX % r <br /> LC LIGHTING CONTROL 11Y' __ EXISTING D5BY OTHERS MADISON l ATC!SUNRISE <br /> M METER _ 11 _� .A _ SITE ADDRESS: <br /> h_ - ) —_ = -- —1 2630 MADISON ST <br /> PB PULL BOX l- F f EVERETT,WA 98203-5476 <br /> PP POWER POLE -1 M ill <br /> T TELCO 1 ` SEAL: <br /> TRN TRANSFORMER 1 EXISTING 11'-6" X 20'-O" <br /> I EQUIPMENT SHELTER <br /> CHAINLINK FENCE ( EXISTING CHAIN-LINK FENCE D AV I D )- <br /> 11 BY OTHERS /Q <br /> W/BARBED WIRE QQ, oc WA$y e0 <br /> Lam—� — —_t' / � NIP tin ,r,,,, e�1E <br /> BUILDINGS,------ 1 / 5'-6" / 8' 2" / <br /> i a- \h 0 47255 44 <br /> 1 <br /> I. I FSS'ONAL C34 <br /> ( 09/22/21 <br /> E <br /> PROPOSED CABLE LENGTH: SURFAr �M® ii e s, <br /> RR <br /> f <br /> 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 125'. <br /> ESTIMATED LENGTH OF CABLE WAS PROVIDED BY \.. <br /> CUSTOMER OR CALCULATED BY ADDING THE RAD <br /> CENTER AND THE DISTANCE FROM THE SHELTER DATE DRAWN. 09/22/21 <br /> ENTRY PLATE TO THE TOWER(ALONG THE ICE - ATC JOB NO: 13671473 <br /> BRIDGE)AND A SAFETY FACTOR MEASUREMENT OF CUSTOMER NAME: MADISON/ATC/SUNRISE <br /> 15%(OF THE TWO PREVIOUS VALUES),CDS DEFER <br /> TO GREATEST CABLE LENGTH. _ CUSTOMER ID: SEO1644A <br /> 2. ROUTE PROPOSED CABLES ALONG SAME PATH AS I ? <br /> EXISTING CABLES AND IN ACCORDANCE WITH �'- <br /> STRUCTURAL ANALYSIS.WHERE POSSIBLE UTILIZE DETAILED SITE PLAN A I I <br /> EXISTING CABLE SUPPORT STRUCTURES AS e <br /> ri s v a v -', ' = DETAILED SITE PLAN <br /> PROVIDED FOR CARRIER TO ADEQUATELY SECURE SCALE:1"=10' <br /> CABLES,USING EITHER APPROPRIATELY SIZED r� <br /> STAINLESS STEEL SNAP-INS OR MOUNTING 0 10' 20' 1� <br /> HARDWARE AND BRACKETS AS SPECIFIED BY CABLE <br /> MANUFACTURER.OTHERWISE,ATTACH CABLES TO 11 <br /> SHEET NUMBER: REVISION: <br /> HORIZONTAL OR DIAGONAL TOWER MEMBERS SCALE 1"=10'(11X17) <br /> USING PROPOSED STAINLESS STEEL ADAPTERS(DO 1"=5'(22X34) <br /> NOT ATTACH TO TOWER LEG). <br /> Li I 23 <br />