E3 UNIT VARIATIONS
<br /> A - BASIC PORCH/ NO POPOUT AT REAR �; , ;
<br /> B - BASIC PORCH/ POPOUT AT REAR -
<br /> C - ENHANCED PORCH/ NO POPOUT AT REAR
<br /> D - ENHANCED PORCH/ POPOUT AT REAR ',
<br /> ,
<br /> SEE BUILDING PLANS FOR WHERE � � '
<br /> VARIATIONS OCCUR ` '
<br /> ��
<br /> �
<br /> �
<br /> _ � '
<br /> � I� :� b �Cpll� d �
<br /> � ;
<br /> INSULATION
<br /> Ar ��chr � ects ;
<br /> � 'tb
<br /> FOUNDATION PERIMETER - R-10 RIGID ' `
<br /> INSULATION TO A DEPTH OF 24" OR TO TOP '
<br /> '�5 Cet�frql �4lay� Surt�2}`0
<br /> iK�rki'�;�ic��Was,h�ngtpn 48033 :
<br /> OF FOOTING AT HEATED PERIMETER �;;P 4�25 4541I,30'F �25.'.G�8 12Q$ �•
<br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS
<br /> OR BLANKETS - R21 �l�l�b �w�v m���rnndt�rck� cq�it .
<br /> FLOORS OVER UNHEATED SPACES - R-30
<br /> ATTICS AT TRUSSES - R-49
<br /> (R-38 SHALL BE DEEMED TO SATISFY THE
<br /> REQUIREMENT OF R-49 WHEREVER THE FULL � REGISTERED
<br /> ARCHITECT
<br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS �
<br /> OVER THE WALL TOP PLATE AT THE EAVES)
<br /> ROBERT E. WEIBLE
<br /> EXTERIOR DOORS: DOORS BETWEEN HEATED STATE OF WASHINGTON
<br /> AND UNHEATED SPACES SHALL BE U=0.30
<br /> OR BETTER
<br /> WINDOWS: ALL WINDOWS AND SGD TO HAVE �
<br /> U-FACTOR OF U=0.30 OR BETTER ro =
<br /> �
<br /> INSULATE UNDER STAIRS AND IN WALL �
<br /> CAVITIES ABOVE BOTTOM OF STRINGERS �
<br /> �
<br /> �
<br /> �
<br /> GYPSUM WALLBOARD SCHEDULE a
<br /> �;
<br /> 5/a" GYPSUM WALL80ARD (GWB) SHALL BE n-
<br /> USED THROUGHOUT ON INTERIOR WALLS, Z
<br /> INTERIOR SIDE OF EXTERIOR WALLS AND -
<br /> CEILINGS EXCEPT AT EXTERIOR WALLS AND �
<br /> COMMON WALLS REQUIRED TO HAVE A 1-NR °'
<br /> OR 2-HR FIRE-RESISTANCE RATING IN L '
<br /> WHICH CASE 5/a" TYPE 'X' GWB SHALL BE a �
<br /> USED. _
<br /> a
<br /> �
<br /> �
<br /> M
<br /> O
<br /> N
<br /> �
<br /> � L
<br /> C .�
<br /> � T
<br /> S
<br /> O
<br /> V
<br /> O OZ
<br /> �
<br /> M � � �
<br /> W o `'
<br /> � N
<br /> a� ,
<br /> a �-
<br /> � �
<br /> V
<br /> M �°
<br /> �
<br /> ,
<br /> W z °' �
<br /> a N
<br /> o �
<br /> Q T
<br /> n �
<br /> W a ,
<br /> M �
<br /> W ° U
<br /> O T �
<br /> m
<br /> �, � 3 a
<br /> Q a �
<br /> � �
<br /> �
<br /> M �
<br /> W
<br /> N � :
<br /> �, � �
<br /> .� a u
<br /> �
<br /> � �
<br /> � `��� � . . . i i i ABOVE. MIN.X�" GWB APPLIED TO �
<br /> � N N Z ; ,',',','.j � i iI ' � � ALL WALLS, BEAMS, AND POSTS �
<br /> <- � z i � � I� I WITHIN GARAGE. '
<br /> �, � � I �L-- � � �6 ;, i Garage �
<br /> I "
<br /> w � •. ' i i I I' D3 SIM. � � a'-�' s'-z1'z' 9,_9Yz' i � ��
<br /> � z . . . . � � � � I �
<br /> v¢, ¢ -----. . . . . . . . . . . . . .-.--.._..---- � ` o L --=:.�:., � �
<br /> �-: �'' . . . . . . . . . . . t � ' ----- ------ - -- - - --- - -----
<br /> , ...............
<br /> ....
<br /> ....................
<br /> . ............................................. :�.
<br /> , ......... ........ .......................... .:
<br /> . .- . . . .. ....... ......... .. ___._._ ...._..__.. .
<br /> . ...
<br /> N O T E S
<br /> _. . ....
<br /> p d' � -- ---- ---------------------------- -` --- INSULATE SOFFIT AROUND BEAM
<br /> �� �O � ��2 ;N OFFlT 16�� OFF CEILING 2, 8„ '� -- I �STAIRS AND BATH EXHAUST 8 � /� �
<br /> FRAMING: 2x6's AT EXTERIOR WALLS THE FIREPLACE SHALL BE LfSTED BY UL OR FM AND � if �
<br /> 2x4's AT INTERIOR WALLS SHALL BE INSTALLED IN ACCORDANCE WlTH THAT �+- �'� D5 2 `\ I' � '� � ,
<br /> UNLESS NOTED OTHERWISE. LISTING � �`' � p, � CONTINUE COMMON WALL � � � i i D1 � �
<br /> - Q D5 GWB THROUGH FURRING � o - 1� � 9 3 Qj
<br /> SEE S1.1 FOR STUD SCHEDULE. `- - ;""' - uP D2 02 0,
<br /> � TYPICAL I� � s ��� ��' '
<br /> PROVIDE WATER RESISTANT GYPSUM WALLBOARD : � SIM. • - ° ......
<br /> •••••••••••••••�•• R-21 BATT INSULATION BEHfND TUB AND SHOWER ENGLQSURE MATERIALS s' = I� \ S�M• � _ . �
<br /> ------ . . . . . W 0
<br /> : : : ..... ..
<br /> 3Yz" ACOUST. INSUL. EACH SIDE TO A NEIGHT OF 70" MINIMUM ABOVE TNE �* �° � � `� � c " �� 0 O
<br /> OF PARTY WALL, UNO. . -�. . . �F1C11. � o� D1 0 � �������� ��o; �
<br /> DRAIN INLET. i_ . . . SOFFIT � p�n� • N " m `� � �.+ C�
<br /> N 7'-10' A.F.F. � `� �o w w A« n r , � ��� W N� = B a t h �' �' o � � Q� C '�'r
<br /> i �W(�r:. : : . : x � t,s'aeov� : o �_ � � .� � siM. t/�
<br /> C O N C E A L E D S P A C E S S H A L L B E F I R E S T O P P E D I N B O T N N Q P L U M B W G M E C N A N I C A L E Q U I P M E N T D U C T S O R I � NOSING. RAli1NG ; N � z*',� �
<br /> � , �,. . . . . . . . . . . � N �
<br /> , „ C° ; 24 TB � neovF To +3s" : o N �
<br /> D1RECTIONS AT 10 -0 ON CENTER AND AT FLOORS. VENTS SHALL BE LOCATED IN THE COMMON UMT � 1 �
<br /> { � INSULATE FLOOR OVER � � ° 2-6 HC LOCATE PI �
<br /> TYPICAL. SEPARATION WALLS PER IRC SEC. R302.2 (EXCEPTION) UNHEATED SPACE � �, : s ' p, ROUGH-IN � O ^�
<br /> � .�. . . . . .'.TP. . . . .�. . ' �z UP ps AORCOMMC i � i
<br /> , . . _ . . . . .
<br /> ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ALL BEDROOM AND BATHROOM DOORS SHALL BE :......... �- ...................... ,•••••••••••� _— �� � Entry 2,_6, 2�_oyz' 7-3y2• �
<br /> ROOMS SHALL HAVE A MINIMUM NET CLEAR OPENING UNDERCUT A MINIMUM OF 3/a" ABOVE THE ADJACENT 1-6 2-6 F - � _ �
<br /> � Z 7-0 5-0 DBL SL I o ' ,��
<br /> OF 5.7 SQUARE FEET. THE MINIMUM CLEAR OPENING FLOOR COVERING. �° AT 6'-9 " ABOV AT 8'-0" A.F.F. � � � /• � � V � � �
<br /> HEIGHT DIMENSION SHALL BE 24 . THE MINIMUM CLEAR ?,,,,,, ,,,,,,; � :. ..: Bedroom 3 � -� ■ . ■ O � Z
<br /> OPENING WIDTH DIMENSION SHAL� BE 20". SILL THE FRONT DOOR SHALL BE OPENABLE FROM THE ND G F.F.
<br /> HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE 1NSIDE WlTHOUT THE USE �F A KEY OR ANY SPECIAL � � LJ � � � �2'-3Yz" z'-3Yz' ' � ° W � W �
<br /> FLOOR PER IRC SEC. R310.1.1. KNOWLEDGE OR EF�ORT. (T MAY BE PROVIDED WITH A � � a
<br /> � ;� o
<br /> NIGNT LATCH, DEAD BOLT OR SECURITY CNAIN, � ' � j i PorCh i � s-o�o sY. '�' �
<br /> WHERE SILL AT OPERABLE WINDOW IS LOCATED MORE PROVIDED SUCH DEVICES ARE OPENABLE FROM THE � � ; _. �r s�-e'A.EF, . � �
<br /> e ...... o ......,....'.
<br /> THAN 72 INCHES ABOVE FINISHED GRADE OR OTHER WSIDE WITHOUT THE USE OF A KEY OR TOOL, AND ' � „5�-63j4 z-_e� � = O
<br /> SURFACE BELOW, SILL HEIGHT SHALL BE MINIMUM 24 MOUNTED NOT TO EXCEED 48 ABOVE TNE FINISHED � , > » � • _� � o,
<br /> INCHES ABOVE FINISHED FLOOR. PER IRC SEC. 312.2.1. FLOQR. 2'-9" 2'-4' 5'-0" 5-0 � ;; ?�° - � D2 I ________J O a
<br /> 5'-1" 2'-0" 10'-0" 2'-0" • � -- �
<br /> ' f �'-�Y8"
<br /> ALL GLAZING SHALL CONFORM TO IRC SEC. R308.4, STAIR NOTES: 19,_�„ ' 6 s�9� �
<br /> HAZARDOUS LOCATIONS. GLAZING IN ALL DQORS SHALL LOCATE HANDRAILS AT 34'-38" ABOVE THE �,_�Y �, ��y4p �
<br /> BE SAFETY GLAZED. AL.L GLAZING WITHIN A 24" ARC STAIR NOSING.
<br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY U N IT E3A & E3 B MIDDLE LEVEL PLAN
<br /> GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS HANDRAIL GRASP DIMENSION SHALL BE BETWEEN 1" & �� '
<br /> GLAZED N, OR "WET SURFACE" SHALL BE SAFETY �ER INATE ROVIDE CONTINUOUS HANDRAIL OR 1/4"=1'-0" BUILDINGS 17 & 18 UNIT E3A & E3B LOWER LEVEL PLAN � Job No.: 13-47
<br /> AT NEWEL POSTS OR SAFETY TERMINAL. SEE U�8 FOR INTERIOR ELEVATIONS �/4"=�'-o" BUILDINGS 17 dc 18 w
<br /> „ � Sheet No.:
<br /> PROVIDE 5/a (MIN.) GYPSUM SHEATHING ON �
<br /> WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE WHERE USED AS A GUARDRAIL, A MAX. OPENING OF AND INTERIC)R STAIR PLANS
<br /> REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION. 4��• M U 7 ■ �
<br /> Sheet Order: A 6 U F R E S D 1 �
<br /> r
<br />
|