|
. i,
<br /> 'i' -__ 1
<br /> 5 D1
<br /> D1 � WINDOW FLASHING �18" GWB
<br /> .
<br /> SYSTEM
<br /> , ,
<br /> � SEALAN T - '
<br /> >
<br /> : z s � ,
<br /> ALL RAILS, GUARDS AND CONNECTIONS ARE TO BE BUILT �
<br /> . . , ..
<br /> .
<br /> __ ,
<br /> �� � � ' AND INSTAL�ED PER SECTION 1607 OF THE 2012 IBC. AND » � � ; ;
<br /> �.... ',. 2 6
<br /> I I � PER TNE MANUFACTURERS SPECIFICATIONS. 5/a GWB BACKER ROD �� 2 2 2 ;' '
<br /> , , SLOPES /a:12 � � ;
<br /> 2 . 2 ' i ALL GUARDRAILS AND CONNECTIONS ARE TO BE DESIGNED & SEALANT SEAI.ANT � WINDOW y�
<br /> ��m FOR A LATERAL LOAD OF 50 POUNDS PER LINEAR FOOT. � �;. JAMB ; �f
<br /> :� 2 6 I
<br /> ; >: �
<br /> 2 i � j 5/ax4 WOOD TRlM '" � ` ' �
<br /> f: 2 6 � WITN DADO JOINT ' ° }
<br /> � FLEXIBLE MEMBRANE 6 6 6 M I � � C � I� � 1 ,
<br /> �o �0 2x10 P.T. LEDGER � I FLASHING :A C � � I 1 � ' L � S ;
<br /> �� .�:3t �;2 .:�J
<br /> % i
<br /> . �.....�',':'.: ." .. . . _
<br /> :
<br /> 2 6 '' C O N T. A N O D I Z E D M E T A L C A P 1 l I WINDOW FLASHING SYSTEM
<br /> 2 6 io OVER WOOD TOP CAP �� ' I 25 C�t ztr pl Way/ Suife 2iQ '
<br /> l6
<br /> ` y�� KtfICIQ�It}t WqSlll#��tf�R 98Q33 .;
<br /> ---
<br /> ,.:...:... .. :: ....: .. ... . :. :.........:�.:.. . �
<br /> � INTEGRATED DRIP EDGE z 4 W.R.B TYP.
<br /> � ¢ ATTACH METAL CAP UNDER � � SHEATHING 5/4x TRIM �P'�425�5q 7j13Q F q25 bS8 12k18 ��
<br /> � -� ; � ; ' � SIDING INSTALL PER MFR WEA7HER—RES(STIVE 'N/�(�,,t���r �n►Ik��a�dxp�ch�arm .
<br /> � TOP TRIM ONLY � � I
<br /> �"I I rn � I � �� REQUIREMENTS BARRIER BEHIND TRIM
<br /> ,I � ; ; INSUL
<br /> DECK-TO-WALL + 1x3 TRIM ; ; 2x4 �—� �'
<br /> B ' i il i FRAMWG A SILL B 1�g 5052 REGISTERED
<br /> SECTION SiDING OVER BUILDING PAPER � ARCHITECT
<br /> OVER �/z" PLYWOOD z z
<br /> � CORNER POST � SEE DETAIL 18/13
<br /> CORNER POST � � � �o BEYOND � FOR BUILDING PROVIDE 2x8 BLOCKING �
<br /> � � � � FOR DRAPPERY EACH
<br /> BEYOND i i DETAOSURE WINDOW ( STATE OF WASHINGTON
<br /> SIDE OF HEADER AT ALL ROBERT E. WEIBLE
<br /> WATERPROOF DECKlNG (COVED) OVER � � OPENING BETWEEN LIVING UNIT BEDROOM
<br /> ONE—PIECE GALV. DOOR PAN OVER PT 2x4 I i i� � RAILS NOT TO I WINDOWS (TYP.) .
<br /> PRE—FLASHING OVER
<br /> DECK—TO—WALL "L" FLASHING i �I i SHIM TO EXCEED 4" I ' '
<br /> ........ ........ . ..... . ... , ,,.
<br /> ; � PUSH OUT 1 :. l
<br /> � BEAM PER STRUC. 2 , 4 i , SIDING FLASHING D1 � �
<br /> � � D 3�/z" WOOD TRIM INSUL. ` �
<br /> � ; SLOPES %4:12 SEE FRAMING �;
<br /> 2 2 z ''� ; SHIM AS NEEDED � : ,� ' ; ,� t
<br /> �i I M� \� 2 PLANS FOR '� �'
<br /> FLASHING HEADER SIZE —' I � SIDING INSTALL Q,
<br /> I � PER MFR. REQ. 'L
<br /> � '; I; 2 2 � � z 2 f�. SEALANT � � i .Q
<br /> 2x10 P.T. LEDGER (MAINTAIN � ;: GUTTE GUTTE 1' 2" RIGID � � 4 I �
<br /> io io� �o � BOTTOM EDGE ELEVATION OF T��. � ��� �� � � ;�� ������ WSULATION �I I �•+
<br /> � » ;: 'r: � : ��
<br /> � � 24 GAGE PPM
<br /> � z s 2 2 +7 —9�/z , RIP TOP AS 2 ; ' 1x6 TRIM 2 .I` ' lx6 TRIM 3/z WINDOW INS � �
<br /> NEEDED TO AL(GN DECK SURFACE)
<br /> f� ��� :f� ��'� TRIM y � FLASH(NG WITH �,
<br /> 2 s , 4 4 4 ;: 4 ;t" 6 6 -: il 2» END DAM —
<br /> , - � � . ......: .. :.:..
<br /> � , , _ : .... ... ... ..... .. < ....: .. -, :...,. ...:.:.. ,,,,, ..:.:.......... .�,,..: .. ..: :: ,. ..:.......: :. .:.....:... . ... , ,.. .,...�, , i� 2x12 FASCIA : ; , ':i 2x12 FASCIA % TRIM --------- ----- 2 � � .
<br /> � :
<br /> � � �.�. , i . , ,;. --- --- ---_- �� WINDOW =
<br /> Q ;-: I�� �°i � .'� � ; FLASHWG � `
<br /> � , � � �; , ' ' SIDING INSTALL � 1 .�,
<br /> � ; � I 2x4 P.T. SOFFIT FRAMING FIBER—CEMENT SOFFIT i '.1 �i i' ��� %4x4 WOOD TRIM �
<br /> °' `'��� � I AT 16" O.C.> TYP. WITH STRIP VENTING '���� �` ' !�� � (2) LAYERS �'a" TYPE 'X' I ,f'���� I��'� PER MFR �4" GAP 4 --- ' �� �
<br /> I �
<br /> i� I j ° T�3UC ` GWB OVER STRUCTURAL �_ � ;` :I � TYP. WIDTH PER �
<br /> + r 1 ' REQUIREMENTS �
<br /> ;:; POST �'.; POST � ,�;, C B ELEVATIONS) —
<br /> , I I D1 � , ,�.� � � SEALANT �
<br /> E� I 4x4 P.T. POST � ' WINDOW �
<br /> ' I " � �,i: f � I /4x4 WOOD TRIM
<br /> � SEE DETAIL 4/D6 FOR BOTTOM � r , , 5 WRAP GWB � WIN�OW �
<br /> I�� I ' � I HARDIE PANEL i ���, ' N E A D A N D J A M B T Y P. „ .�
<br /> �.< i HALF OF COLUMN DETAILING AND I , i BACKER ROD & SEAI�ANT o .
<br /> FOUNDATION CONDfTION � � i ���' ' � �� � �
<br /> 3/2 WOOD TRIM MIN. GAP SHOWN SEE �
<br /> �
<br /> SEALANT �
<br /> A
<br /> �-
<br /> MFR INSTALLATION ,�
<br /> ALTERNATE RAILING STYLE wsTRucTioNs MIN. 10° z O
<br /> A DECK AT CANTILEV ERED L IVI N C S P A C E C D E C K E D C E (S E E B L D G. E L E V A T I O N S F O R L O C A T I O N S) REPRESENTATIVE ELEVATION s�oPE *
<br /> SECTION SECTION C JAMB D HEAD
<br /> �
<br /> WATERPR40F DECK DETAILS WINDOW DETAILS � `°
<br /> �
<br /> 18 6 0 ,
<br /> � N
<br /> a� ,
<br /> 1-1/2" = 1'-0" 3„ _ �'-0" � �
<br /> N �
<br /> , Z 4 ;, COUNTER TOP Y � o
<br /> � � �
<br /> Gc N
<br /> � ' OPENING BETWEEN � �
<br /> � Q o
<br /> z z 2"x 3/8" SIDE CAP TRIM , 2 4 . �w
<br /> � ; � � RAILS NOT TO � 2 , :
<br /> ' � � ' � EXCEED 4" � BASE CABINET SEE �
<br /> WATERPROOF DECKING � � j ° ° INTERIOR ELEVATIONS � V?
<br /> INSTALL PER MANUF. � 2 4 ;; ; FOR DIMENSIONS COUNTERTOP � O
<br /> �/2" PLYWD. 0/ 3�4�� PLYWD. �Q \Q � m
<br /> � � � � � � Q � �
<br /> � .� �
<br /> EDGE DR1P EDGE DRIP 5�g�� GWB OVER ` Q � Z 6 ; � o
<br /> � � 2 FLASNING 2 2 FLASHING 2x STUDS AT 16" OC. ; 5/s" GWB � ------------;� ; Q
<br /> RIPPED 2x10 JSTS. ' I ' �
<br /> AT 16" O.C. .
<br /> SEE FRMG. PLANS 1x6 TRIM lx6 TRIM � ' � "'
<br /> ; ,
<br /> KITCHEN � � ;
<br /> ... .. . ..... . . . .. . . ..... ...... . ....... ....�__. .....
<br /> � � � CABINET � ; � TYPICAL EXTERIOR � �
<br /> --��
<br /> VENTED FIBER—CEMENT 2x12 FASCIA 2x12 FASCIA I I � WALL � '�
<br /> SOFFIT >
<br /> ALTERNATE RAILWG STYLE
<br /> (SEE BLDG. ELEVATIONS FOR LOCATIONS)
<br /> •F•+
<br /> WATERPROOF DECK SIDE EDGE KITCHEN END WALL KITCHEN WINDOW/COUNTER �
<br /> 11 „ , » 7 » , „ 3 �. > >. :
<br /> 1-1/2 = 1 -0 SECTION �—�/2 = � —o SECTION 1-1/2 = 1 -0 SECTION � �
<br /> �. _
<br /> 0 �
<br /> �'-4" � Q ,
<br /> 1" � �
<br /> �a" BAR TOP G� � �
<br /> ---� A-4'� ABOVE W � � U
<br /> ELECTRICAL BOX 6 : FINISH FLOOR � � ,�.�
<br /> MOUNTED ON SID� 2 6 ' � N
<br /> �;� . l ; 2 �a" COUNTERTOP a � NN �
<br /> � ; ______; DECORATIVE CORBELS (2) � � � �
<br /> �--- 6 ; ---� 36" ABOVE J .�+
<br /> 36" ABQVE 6 ` FINISH FLOOR = � O
<br /> FINISH FLOOR CABINET 6 " V � y Z
<br /> 2 � �
<br /> �'s" GWB OVER 2x STUDS CABINET DECORATIVE CORBELS (2) � uj = '
<br /> AT 16" OC. � O
<br /> 6 ; .� �
<br /> 5/a" GWB OVER = �
<br /> 2x STUDS AT 16" OC. _ —
<br /> 5/a" TYPE 'X' GWB OVER � Q
<br /> 2x STUDS AT 16" OC. 5/a" TYPE 'X' GWB OVER � Q a
<br /> 2x STUDS AT 16" OC. 4 �
<br /> ' r
<br /> �
<br /> � Q,
<br /> Q
<br /> �
<br /> J
<br /> O
<br /> KITCHEN COUNTER @ BAR TOP KITCHEN COUNTER �0 1obNo.: 13-47 �
<br /> 8 „ , „ � „ , „ � Sheet No.:
<br /> 1-1/2 = 1 -0 SECTION 1-1/2 = 1 -0 SECTION o
<br /> � D4
<br /> Sheet Order: A B U F R E S D I �
<br /> T
<br />
|