House Specifications & work Recommended <br /> Site Drainage Recommendations: <br /> None <br /> Roof Drain Discharge Recommendations: <br /> Roof drains appear to be draining to the bay and do not tie into private <br /> sewer there are 9 downspouts and 3 driveway drains <br /> Internal Plumbing: <br /> The existing backwater valve is located in the downstairs powder room <br /> under the floor the NE corner of the floor recommend replacing the <br /> backwater valve <br /> Side Sewer Recommendations: <br /> Building upper level line has no accessible camera access, level tie in <br /> outside approx. 32' in front of house and 13' off garage see chart on <br /> file. Connection is 8'10" deep from surface recommend installing <br /> backwater valve downstream of where both lines tie in. line is approx. <br /> 90' to city main line is clay and should be re-lined line has multiple <br /> bellies line should be jetted to clear build up. <br />