4122 COLBY AVE 2020 Plans 2022-12-01
>
Address Records
>
COLBY AVE
>
4122
>
Plans
>
4122 COLBY AVE 2020 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:19:22 AM
Creation date
6/14/2022 3:57:27 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4122
Permit
B2004-029
Year
2020
Notes
NEW 3-STORY WOOD-FRAMED TOWNHOUSE / DUPLEX
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WINDOW SCHEDULE <br />NUMBER <br />ROOM NAME <br />FLOOR <br />OTY <br />SIZE <br />WIDTH <br />HEIGHT <br />R/O <br />DESCRIPTION <br />HEADER <br />EGRE55 <br />TEMPERED <br />U-FACTOR <br />MANUFACTURER <br />W01 <br />U1-BATH 2 <br />2 <br />1 <br />25400H <br />32 " "on <br />33"X49" <br />DOUBLE HUNG <br />2XbX36" 2 <br />YE5 <br />0.25 <br />Mil and Narrow Frame Trinsic Series <br />W02 <br />U1-HALL <br />3 <br />1 <br />2840DH <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2X6X36" (2) <br />0.28 <br />W03 <br />U1-BEDROOM 2 <br />3 <br />2 <br />36401-5 <br />42 " <br />48 " <br />43"X49" <br />LEFT 5LIDING <br />2X6X46" 2 <br />YE5 <br />0.25 <br />W04 <br />U2-BEDROOM 2 <br />3 <br />1 <br />3640R5 <br />42 " <br />48 " <br />43"X49" <br />RIGHT 5LIDING <br />2XbX46" 2 <br />YE5 <br />0.28 <br />Y405 <br />U1-BEDROOM 1 <br />2 <br />2 <br />1040T5 <br />84 " <br />4611 <br />85 %49" <br />TRIPLE 5LIDIN6 <br />2X6X88" 2 <br />YES <br />0.28 <br />WOb <br />U1-BEDROOM 2 <br />3 <br />2 <br />1040T5 <br />84 " <br />48 " <br />85"X49" <br />TRIPLE 5LIDING <br />2XbX88" (2) <br />YES <br />0.26 <br />W01 <br />U1-CL05ET BED 1 <br />2 <br />1 <br />28400H <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2X6X36" 2 <br />0.28 <br />W08 <br />U1-GREAT <br />2 <br />1 <br />1040T5 <br />84 " <br />48 " <br />$5"X49" <br />TRIPLE 5LIDING <br />2X6X88" 2 <br />0.28 <br />W09 <br />U1-GREAT/U1-BALCONY <br />2 <br />2 <br />26400H <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2XbX36" 2 <br />YES <br />0.28 <br />W10 <br />U2-13ATH 1 <br />2 <br />1 <br />2840DH <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2X6X36" (2) <br />YE5 <br />0.28 <br />W11 <br />U2-BEDROOM 1 <br />2 <br />2 <br />1040T5 <br />84 " <br />46 " <br />85"X49" <br />TRIPLE 5LIDING <br />2X6X88" 2 <br />YE5 <br />0.25 <br />W12 <br />U2-5EDROOM 2 <br />3 <br />1 <br />36401.5 <br />42 " <br />46 " <br />43"X49" <br />LEFT 5LIDING <br />2XbX46" 2 <br />YE5 <br />0.25 <br />W13 <br />U2-BEDROOM 2 <br />3 <br />1 <br />1040T5 <br />84 " <br />48 " <br />85"X49" <br />TRIPLE 5LIDING <br />2XbX88" 2 <br />YES <br />0.28 <br />W14 <br />U2-BEDROOM 3 <br />3 <br />1 <br />'1040T5 <br />84 " <br />48 " <br />85"X49" <br />TRIPLE 5LIDING <br />2XbX88" (2) <br />YE5 <br />0.28 <br />W15 <br />U2-6105ET BED 1 <br />2 <br />1 <br />2840DH <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2X6X36" 2 <br />0.28 <br />W16 <br />U2-GREAT <br />2 <br />1 <br />11040TS <br />64 " <br />4511 <br />85"X49" <br />TRIPLE 5LIDING <br />2X6X88" 2 <br />0.28 <br />W11 <br />U2-GREAT/U2-BALCONY <br />2 <br />2 <br />28400H <br />32 " <br />4611 <br />33"X49" <br />DOUBLE HUNG <br />2XbX36" 2 <br />YES <br />0.26 <br />W18 <br />U2-HALL <br />3 <br />1 <br />2840DH <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2X6X36" (2) <br />0.28 <br />W19 <br />U1-BATH <br />1 <br />1 <br />2840DH <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2X6X36" 2 <br />0.25 <br />W20 <br />U2-BEDROOM 1 <br />1 <br />1 <br />28400H <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2XbX36" 2 <br />YE5 <br />0.28 <br />W21 <br />U1-BEDROOM 1 <br />1 <br />2 <br />25400H <br />32 " <br />48 " <br />33"X49" <br />DOUBLE HUNG <br />2XbX36" 2 <br />0.28 <br />W22 <br />U2-13ATH <br />1 <br />1 <br />2840DH <br />32 " <br />46 " <br />33"X49" <br />DOUBLE HUNG <br />2XbX36" 2 <br />0.28 <br />W24 <br />U2-BEDROOM 1 <br />11 <br />1 <br />404ODH <br />14b " <br />10 " <br />49"X49" <br />IDOUBLE HUNG <br />2XbX52" 2 <br />YE5 <br />I <br />0.28 <br />Ductless Split System Heat Pump Per Unit <br />4 Air handlers in each bedroom. , <br />Supplemented with Electric Wall Heaters per plan <br />Typ. Hot water tank per unit <br />r <br />Property AddresA120 COLBY AVE. EVERETT WA q&203 <br />Conditioned Floor Area: 1,136 5F Date: 12 / 25 11 q <br />Builder or registered design professional <br />KE5H DE516N LINE5 <br />Signature: Ke,l CH-avata. <br />Ceiling: Vaulted R- 4q Floors: Over unconditioned space R- 38 <br />Attic R- 4cl Slab on grade floor R- 10 <br />Wails: Above grade R- 21 Doors: R- <br />Below, int. R- 10 R- <br />Below, ext. R- R- <br />NFRC rating (or) Windows U- 0.25 <br />Default rating (Appendix A WSEC 2015) Skylights U- 0.50 <br />leafing Electric Ductless Heat Pump <br />Aolmg N/A <br />DHW Gas Water Heater w/ Girc. pump <br />26 <br />Provide Min. 100 GFM Whole House Vent Fan. Vent to exterior w/ min. 5" smooth <br />duct & max. (1) 90 dgree bend. Install intermittent timer system. Controls to be <br />located in a readily accesable location. Instuctions to be provided by installer to <br />occupant. Operation to be set to run a min. of 1 hr. out of every 4 hrs. Provide <br />manual & automatic control. Set per calculated vent rates at final inspection. <br />Provide lable on control that reads "Whole house ventilation (See operation <br />instructions). <br />SHGC- N/A <br />SHGC- N/A <br />q2% AFUE <br />EF- .qq <br />All ducts & HVAC in conditioned space & <br />no Insulation R- 8 <br />Air handler present e <br />no) <br />Test Target CFM@25Pa Test Result CFM@25Pa <br />Building air leakage target: ACH50 < 5.0 - Tested leakage: ACH50 = <br />System type: <br />Rated annual generation Kwh <br />Table 406.2 <br />Enerav Credits (2015 Code) <br />OPTION <br />DESCRIPTION <br />CREDIT(S) <br />Estimated Cost <br />la <br />EFFICIENT BUILDING ENVELOPE Ia: <br />0.5 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.28 <br />Floor R-38 <br />Slab on grade R- 10 perimeter and under entire slab <br />Below grade slab R-10 perimeter and under entire slab <br />or <br />Compliance based on Section R402.1.4: Reduce the Total UA by 5%. <br />lb <br />EFFICIENT BUILDING ENVELOPE lb: <br />1.0 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.25 <br />Wall R-21 plus R-4 <br />Floor R-38 <br />Basement wall R-21 mt plus R-5 ci <br />Slab on grade R-10 perimeter and under entire slab <br />Below grade slab R- 10 perimeter and under entire slab <br />or <br />Compliance based on Section R402.1.4: Reduce the Total UA by t5%. <br />lc <br />EFFICIENT BUILDING ENVELOPE lc: <br />2.0 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U - 0.22 <br />Ceiling and single -rafter or joist -vaulted R-49 advanced <br />Wood frame wall R-21 int plus R-12 ci <br />Floor R-38 <br />Basement wall R-21 int plus R-12 ci <br />Slab on grade R- 10 perimeter and under entire slab <br />Below grade slab R- 10 perimeter and under entire slab <br />or <br />Compliance based on Section R402.1.4: Reduce the Total UA by 30%. <br />Ida <br />EFFICIENT BUILDING ENVELOPE Id: <br />0.5 <br />Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br />Vertical fenestration U = 0.24 <br />2a <br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: <br />0.5 <br />Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per <br />hour maximum <br />and <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code shall be met with a high efficiency fan (maximum 0.35 <br />watts/cfm), not interlocked with the furnace fan. Ventilation systems using a furnace <br />including an ECM motor are allowed, provided that they are controlled to operate at <br />low speed in ventilation only mode. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum tested building air leakage and shall <br />show the qualifying ventilations stem. <br />2b <br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: <br />1.0 <br />Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air <br />changes per hour maximum <br />and <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code shall be met with a heat recovery ventilation system <br />with minimum sensible heat recovery efficiency of 0.70. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum tested building air leakage and shall <br />show the heat recovery ventilations stem. <br />WINDOW AND DOOR NOTES: <br />EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRE55 WINDOW <br />WITH FIN15H SILL HEIGHT NOT GREATER THAN 44" ABOVE THE <br />FIN15H FLOOR HEIGHT AND SHALL HAVE A MINIMUM OPENABLE <br />AREA OF 51 50. FT. E6RE55 WINDOWS SHALL NOT HAVE AN <br />OPENABLE AREA LE55 THAN 20" WIDE OR 24" HIGH. <br />24" MININUM ELEVATION OF WINDOW OPENING ABOVE SECOND <br />LEVEL FINISHED FLOOR. <br />INTERIOR DOORS SHALL BE PAINTED, ENTRY DOOR TO BE <br />DEFINED BY HOME OWNER PRIOR ORDERING <br />DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" <br />TIGHT FITTING SOLID GORE DOORS WITH A FIRE RATING OF 60 <br />MINUTES. DOOR SHALL BE SELF GL05ING. <br />EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOORWAY <br />SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE <br />WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR <br />EFFORT. <br />Table 406.2 <br />Enerav Credits (2015 Code) <br />OPTION <br />DESCRIPTION <br />CREDIT(S) <br />Estimated Cost <br />2c <br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: <br />1.5 <br />Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air <br />changes per hour maximum <br />and <br />All whole house ventilation requirements as determined by Section M1507.3 of the <br />International Residential Code shall be met with a heat recovery ventilation system <br />with minimum sensible heat recovery efficiency of 0.85. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the maximum tested building air leakage and shall <br />show the heat recovery ventilations stem. <br />3a <br />HIGH EFFICIENCY HVAC EQUIPMENT 3a: <br />1.0 <br />Gas, propane or oil -fired furnace with minimum AFUE of 94%, or <br />Gas, propane or oiled -fired boiler with minimum AFUE of 92% <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />equipment efficiency. <br />3b <br />HIGH EFFICIENCY HVAC EQUIPMENT 3b: <br />1.0 <br />Air -source heat pump with minimum HSPF of 9.0 <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />equipwent efficiency. <br />3c <br />HIGH EFFICIENCY HVAC EQUIPMENT 3c: <br />1.5 <br />Closed -loop ground source heat pump; with a minimum COP of 3.3 <br />or <br />Open loop water source heat pump with a maximum pumping hydraulic head of 150 <br />feet and minimum COP of 3.6 <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />equipment efficiency. <br />3d <br />HIGH EFFICIENCY HVAC EQUIPMENT 3d: <br />1.0 <br />Ductless Split System Heat Pumps, Zonal Control: In homes where the primary space <br />v <br />heating system is zonal electric heating, a ductless heat pump system shall be installed <br />and provide heating to the largest zone of the housing unit. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and the minimum <br />equipment efficiency. <br />4 <br />HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: <br />1.0 <br />All heating and cooling system components installed inside the conditioned space. <br />This includes all equipment and distribution system components such as forced air <br />ducts, hydronic piping, hydronic floor heating loop, convectors and radiators. All <br />combustion equipment shall be direct vent or sealed combustion. <br />For forced air ducts: A maximum of 10 linear feet of return ducts and 5 linear feet of <br />supply ducts may be located outside the conditioned space. All metallic ducts located <br />outside the conditioned space must have both transverse and longitudinal joints sealed <br />with mastic. If flex ducts are used, they cannot contain splices. Flex duct connections <br />must be made with nylon straps and installed using a plastic strapping tensioning tool. <br />Ducts located outside the conditioned space must be insulated to a minimum of R-8. <br />Locating system components in conditioned crawl spaces is not permitted under this <br />option. <br />Electric resistance heat and ductless heat pumps are not permitted under this option. <br />Direct combustion heating equipment with AFUE less than 80% is not permitted <br />under this option. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the heating equipment type and shall show the <br />location of the heating and cooling equipment and all the ductwork. <br />Table 406.2 <br />Enerav Credits (2015 Code) <br />VENTILATION NOTES: <br />ALL COMBUSTION APPLIANCES WILL BE VENTED DIRECTLY TO THE <br />EXTERIOR- FURNACE FIREBOX AND TANKLE55 WATER HEATER <br />SHALL HAVE OUTSIDE COMBUSTION AIR SUPPLY PURSUANT TO <br />REGIONAL AND LOCAL CODES. <br />ATTIC SHALL HAVE VENTILATION EQUAL TO 1 5a. FOOT PER 300 <br />5a. FEET OF ATTIC SPACE. VENTILATION SHALL BE PROTECTED <br />FROM SNOW AND RAIN AND SHALL BE COVERED WITH <br />GALVANIZED WIRE SCREEN. OPENING5 SHALL BE LOCATED TO <br />PROVIDE GRO55 VENTILATION. <br />EXHAUST ALL VENTS AND FAN5 DIRECTLY TO OUTSIDE VIA METAL <br />DUGT5, PROVIDE 50 GFM (MIN) FANS TO PROVIDE 5 AIR CHAN6E5 <br />PER HOUR IN BATHS GONTAINING TUB AND / OR 5HONER AND IN <br />LAUNDRY ROOMS. <br />UNDER FLOOR SPACES SHALL HAVE VENTILATION EQUAL TO ONE <br />5a. FOOT PER 150 5a. FEET OF FLOOR SPACE. VENTS SHALL BE <br />CAST INTO THE CONCRETE STEM WALL5 AND COVERED WITH <br />GALVANIZED WIRE SCREEN. VENTS SHALL BE LOCATED TO <br />PROVIDE GROSS VENTILATION. <br />OPTION <br />DESCRIPTION <br />CREDIT(S) <br />Estimated Cost <br />5a <br />EFFICIENT WATER HEATING 5a: <br />0.5 <br />All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 <br />GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less.` <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />X <br />being selected and shall specify the maximum flow rates for all showerheads, kitchen <br />sink faucets, and other lavatory faucets. <br />5b <br />EFFICIENT WATER HEATING 5b: <br />1.0 <br />Water heating system shall include one of the following: <br />Gas, propane or oil water heater with a minimum EF of 0.74 <br />or <br />Water heater heated by ground source heat pump meeting the requirements of Option <br />3c. <br />or <br />For R-2 occupancy, a central heat pump water heater with an EF greater than 2.0 that <br />would supply DHW to all the units through a central water loop insulated with R-8 <br />minimum pipe insulation. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the water heater equipment type and the minimum <br />equipment efficiency. <br />5c <br />EFFICIENT WATER HEATING 5c: <br />1.5 <br />Water heating system shall include one of the following: <br />Gas, propane or oil water heater with a minimum EF of 0.91 <br />/ <br />or <br />Solar water heating supplementing a minimum standard water heater. Solar water <br />heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the <br />Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 <br />Certified Solar Water Heating Systems <br />or <br />Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards <br />of NEEA's Northern Climate Specifications for Heat Pump Water Heaters <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall specify the water heater equipment type and the minimum <br />equipment efficiency and, for solar water heating systems, the calculation of the <br />minimum energyg savings. <br />5d <br />EFFICIENT WATER HEATING 5d: <br />0.5 <br />A drain water heat recovery unit(s) shall be installed, which captures waste water heat <br />from all the showers, and has a minimum efficiency of 40% if installed for equal flow <br />or a minimum efficiency of 52% if installed for unequal flow. Such units shall be <br />rated in accordance CSA B55.1 and be so labeled. <br />To qualify to claim this credit, the building permit drawings shall include a plumbing <br />diagram that specified the drain water heat recovery units and the plumbing layout <br />needed to install it and labels or other documentation shall be provided that <br />demonstrates that the unit complies with the standard. <br />Table 406.2 <br />Enerav Credits (2015 Code) <br />OPTION <br />DESCRIPTION <br />CREDIT(S) <br />Estimated Cost <br />6 <br />RENEWABLE ELECTRIC ENERGY: <br />0.5 <br />For each 1200 kWh of electrical generation per each housing unit provided annually <br />by on -site wind or solar equipment a 0.5 credit shall be allowed, up to 3 credits. <br />Generation shall be calculated as follows: <br />For solar electric systems, the design shall be demonstrated to meet this requirement <br />using the National Renewable Energy Laboratory calculator PV WATTs. <br />Documentation noting solar access shall be included on the plans. <br />For wind generation projects designs shall document annual power generation based <br />on the following factors: <br />The wind turbine power curve; average annual wind speed at the site; frequency <br />distribution of the wind speed at the site and height of the tower. <br />To qualify to claim this credit, the building permit drawings shall specify the option <br />being selected and shall show the photovoltaic or wind turbine equipment type, <br />provide documentation of solar and wind access, and include a calculation of the <br />minimum annual energy power production. <br />lY <br />W <br />m <br />o <br />Z <br />T <br />W <br />W <br />2 <br />U) <br />�0 <br />No N N <br />U <br />X <br />N N N <br />Y <br />N <br />N `^' <br />t7p <br />CD0o <br />m <br />Z <br />W <br />< <br />LLI <br />C) <br />Q a) 0 <br />IY <br />0 <br />X <br />LU <br />W <br />�o <br />N <br />d <br />m� <br />>0 <br />m <br />J <br />�w <br />WE <br />O <br />� <br />U� <br />W <br />0 <br />� � <br />s <br />�i <br />x° 3 <br />