J2 <br />11 <br />�111 <br />CORNER TRIM PER DESIGN DOCS <br />I <br />(I EX. INSULATION & FRAMING <br />Copyright 02018 All rights reserved. <br />J2 Building Consultants, Inc. <br />(I EX SHEATHING <br />EX SIDING OR NEW SIDING TO MATCH EX, TYP. <br />SIDING TO MATCH EX. <br />WRB FIELD LAYER LAPS METAL FLASHING, SET IN SEALANT <br />8425 44t Ave. W. <br />OVERLAP WRB MIN. 12" PAST CORNERS, TYP. <br />I <br />4" SAF (STRAIGHT FLASH) OVER TOP OF METAL, TYP, <br />Mukifteo, WA 98275 <br />EXISTING <br />I <br />II <br />Te1425.774.5600 <br />STRUCTUREYA <br />I I FINISH CAULKING @ SIDING TERMINATIONS, TYP. <br />Fax 425.774.5661 <br />wwwJ2Consultants com <br />I ( TAMLYN W INSIDE CORNER TRIM <br />A <br />II <br />I <br />4� FINISH CAULKING @ SIDING TERMINATIONS, TYP. <br />1/4" WEEP, TYP. <br />H <br />L <br />( <br />IY <br />OVERLAP WRB MIN 17 PAST CORNERS, TYP. <br />_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ <br />1 <br />,1�� <br />I FRY REGLET Z-FLASHING PER SIDING MFR <br />- SIDING TO MATCH EX. <br />�I i{�� <br />12495 REGISTERED <br />i i <br />ARCHITECT <br />WRB PER DESIGN DOCS <br />III WRB FIELD LAYER <br />BRIAN FAJARDO <br />I <br />STATE OF WASHINGTON <br />EX SHEATHING <br />i <br />EX INSULATION & FRAMING <br />1 /A7.1 <br />TRIM AT OUTSIDE CORNER -PANEL SIDING NO R.S. <br />SCALE: NTS <br />2 /A7.1 <br />INSIDE CORNER - TYPICAL SIDING <br />SCALE: NTS <br />3 /A7.1 <br />THRU-WALL FLASHING - PANEL SIDING <br />SCALE: NTS, <br />Nores: <br />1. CONTRACTOR IS RESPONSIBLE <br />FOR FIELD VERIFICATION OF <br />SIZING AND QUANTITIES OF ALL <br />COMPONENTS. <br />2. MOCK UP REVIEW OF ALL <br />�qld 1/4" FOLDED END DAM <br />EXTERIOR ASSEMBLIES <br />4• <br />(WHERE INDICATED) <br />REQUIRED BEFORE INSTALLATION. <br />3. DRAWINGS ARE DIAGRAMMATIC <br />ONLY AND ARE NOT TO BE USED <br />WRB/AIR BARRIER <br />FOR TAKE OFF QUANTITIES. <br />CONTINUOUS BEAD OF SEALANT <br />WRAP ROLL AT ONE SIDE AROUND CORNER MIN. 17 <br />SLOPE TO DRAIN <br />w LAP COURSE ON ADJACENT WALL OVER FIRST <br />HEMMED DRIP EDGE, TYP. <br />COURSE AND AROUND CORNER MIN. 12" <br />/ <br />1 <br />CREATING A WEAVE <br />'Alv <br />LAP JOINTS A MINIMUM OF 4' <br />START W/ IQ ROLL <br />APPLY 2 BEADS OF SEALANT <br />CL <br />g "VAPROTAPE" <br />AIR BARRIER <br />TAPE VERTICAL SEAMS <br />F, <br />Revisions: <br />EX INSULATION &FRAMING <br />Date Description <br />EX. SHEATHING <br />FIELD WRB <br />NOTE: REFER TO MANUFACTURER'S <br />EX SIDING OR SIDING TO MATCH EX <br />INSTRUCTIONS FOR WRB/ AIR BARRIER INSTALL <br />FRY REGLET H-VERTICAL FLASHING PER SIDING MFR <br />OUTSIDE CORNER INSIDE CORNER <br />4 /A7.1 <br />VERTICAL FLASHING- PANEL SIDING <br />SCALE: NTS <br />5 /A7.1 <br />I TYPICAL WRB APPLICATION <br />SCALE: NTS <br />6 /A7.1 <br />I TYPICAL FLASHING STANDARDS <br />SCALE: NTS <br />EX. FINISH FLOOR <br />CONT. SEALANT BETWEEN BACK ANGLE AND THRESHOLD <br />I SIDING PER DESIGN DOGS <br />EX SWING DOOR, TO BE REMOVED AND REINSTALLED <br />Project Title: <br />WRB LAPS METAL HEAD FLASHING; <br />THRESHOFIELD SEALANT 0 RUN <br />SET ON BED OF STALLED <br />APPLY SEALANT BETWEEN WRB AND SAF <br />j <br />FRONT TO BACK ACK ON PAN AND IND EVERY 6NT, <br />NAUTI A CONDOMINIUMS <br />C O <br />6" SAF OVER HEAD FLASHING <br />SHIM <br />SHIM DOOR PAN TO SLOPE PAN TO EXTERIOR <br />ROOF REPLACEMENT <br />SHEATHING PER DESIGN DOCS <br />EX DOOR TO REMAIN IN PLACE <br />II SEALANT PER DESIGN DOGS <br />i <br />281E GRAND AVENUE <br />I� 3/8" MINIMUM DRAIN GAP, TYP, <br />I <br />EVERETT WA 98201 <br />v " I <br />I" 26 GA. PRE FINISHED METAL HEAD FLASHING W/ 4"BACK LEG <br />DRIP EDGE, FOLDED END DAMS &SLOPING HORIZONTAL LEG <br />MTL PAN W/ SOLDERED END DAMS AND BACK DAM; ADD <br />REMOVABLE COUNTER FLASHING AT FRONT SIM, TO FRY <br />REGLET; EMBED PAN IN SEALANT. RE.1/A7.2 <br />2818 GRAND AVENUE <br />EVERETT WA 98201 <br />OVER DOOR TRIM <br />Sheet Title: <br />FASTEN CAP SHEET PER MFR AT 8" O.C. MAX ALONG HORIZ. EDGE <br />I PRE -WRAP WRB INTO ROUGH OPENING & SEAL W/ SPRAY FOAM <br />— FLASHING CAP SHEET PER DESIGN DOGS; EXTEND 1" MIN. <br />TRIM PER DESIGN DOGS7.BACKER <br />ROD & SEALANT PER DESIGN DOCS <br />BEYOND FLASHING ASE PLY <br />WALL DETAILS <br />SEALANT PER DESIGN DOCS <br />I FLASHING BASE PLY; EXTEND 3" MIN. PAST BASE OF WALL <br />SAF OVER GAP <br />4" SAF OVER GAP BETWEEN FRAMING AND DOOR FRAME <br />,I CAP SHEET PER DESIGN DOGS <br />TRIM PER DESIGN DOCS <br />3" MIN. 1" MIN. BASE PLY PER DESIGN DOGS <br />SEALANT PER DESIGN DOCS <br />{, COVERBOARD PER DESIGN DOCS <br />Scale: AS Noted <br />EX DOOR, TO BE REMOVED & REINSTALLED <br />PERMIT SET <br />WRB PER DESIGN DOGS <br />I �� <br />Drawn By: <br />NKC <br />SIDING PER PINS <br />Checked By: <br />DD <br />EX INSULATION & FRAMING EX SHEATHING <br />Issue Date: <br />Sheet Number. <br />01 /27120 <br />A7.1 <br />Job#. <br />7 /A7.1 <br />SWING DOOR HEAD REMAIN IN PLACE - TYPICAL SIDING <br />SCALE: NTS <br />8 /A7.1 <br />SWING DOOR JAMB REMAIN IN PLACE - TYPICAL SIDING <br />SCALE: NTS <br />9 /A7.1 <br />SWING DOOR DOOR SILL - ELEVATED TRANSITION - SBS MODIFIED BITUMEN ROOF <br />SCALE: NTS <br />0580217 <br />