CONTRACTOR NOTES: <br />THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE <br />CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. <br />CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS <br />OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID <br />CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH <br />THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF <br />NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR <br />OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF <br />DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, <br />UNLESS DIRECTED OTHERWISE. <br />DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, AND THIS <br />SET OF PLANS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS <br />NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE <br />FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANYTHING ELSE DEEMED NECESSARY <br />TO COMPLETE INSTALLATIONS AS DESCRIBED HEREIN. <br />PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS INVOLVED SHALL VISIT THE JOB <br />SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE NEW PROJECT, <br />WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS, FIELD CONDITIONS AND CONFIRM <br />THAT THE PROJECT MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH <br />CONSTRUCTION. ANY ERRORS, OMISSIONS, OR DISCREPANCIES ARE TO BE BROUGHT TO <br />THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING. <br />THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION 10 PROCEED WITH <br />CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE <br />CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. <br />THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE <br />CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, <br />TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF <br />THE WORK UNDER THE CONTRACT. <br />THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO <br />MANUFACTURER'S/ VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE <br />LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. <br />ALL WORK PERFORMED ON PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT <br />ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR <br />SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS <br />AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY <br />SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE <br />PERFORMANCE OF THE WORK. <br />TIGHTEN ALL BOLTS FOR EQUIPMENT SUPPORTING FRAMES & ALL OTHER STRUCTURES <br />MOUNTED / CONNECTED TO POLES, TOWERS, PARAPETS, ETC., FIRST TO RISC SNUG <br />REQUIREMENTS & THEN TO AISC "TURN OF THE NUT" METHOD. <br />CONNECTION BOLTS SUBJECT TO DIRECT TENSION SHALL BE INSTALLED & TIGHTENED AS <br />PER SECTION 8.2.1 OF THE AISC SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR <br />A490 BOLTS, LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION. <br />THE INSTALLATION PROCEDURE IS PARAPHRASED AS FOLLOWS: <br />FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES & TIGHTENED BY ONE OF <br />THE METHODS DESCRIBED IN SUBSECTION 8.2.1 THROUGH 8.2.4. <br />8.2.1 TURN -OF -THE -NUT TIGHTENING: <br />BOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION & BROUGHT TO A SNUG <br />TIGHT CONDITION AS DEFINED IN SECTION 8.1, UNTIL ALL THE BOLTS ARE <br />SIMULTANEOUSLY SNUG TIGHT & THE CONNECTION IS FULLY COMPACTED. FOLLOWING THIS <br />INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL TIGHTENED FURTHER BY THE <br />APPLICABLE AMOUNT OF ROTATION SPECIFIED ABOVE. DURING THE TIGHTENING OPERATION <br />THERE SHALL BE NO ROTATION OF THE PART NOT TURNED BY THE WRENCH. TIGHTENING <br />SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OF THE JOINT IN A <br />MANNER THAT WILL MINIMIZE RELAXATION OF PREVIOUSLY PRETENSIONED BOLTS. <br />ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHT TO A SNUG TIGHT CONDITION AS <br />DEFINED IN SECTION 8.1 OF THE SPECIFICATION. <br />METAL NOTES: <br />PART 1 - GENERAL <br />1. SECTION INCLUDES: <br />STRUCTURAL STEEL FRAMING MEMBERS, BASE PLATES, PLATES, BARS AND GROUTING <br />UNDER BASE PLATES. <br />2. SUBMITTALS: <br />SHOP DRAWINGS: INDICATE SIZES, SPACING, AND LOCATIONS OF STRUCTURAL <br />MEMBERS, OPENINGS, CONNECTIONS, CAMBERS, LOADS, AND WELDED SECTIONS. <br />3. QUALITY ASSURANCE <br />A. FABRICATE STRUCTURAL STEEL MEMBERS IN ACCORDANCE WITH AISC <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS. <br />B. PERFORM DESIGN UNDER DIRECT SUPERVISION OF A PROFESSIONAL STRUCTURAL <br />ENGINEER LICENSED IN THE STATE. <br />THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED <br />BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. PART 2 - PRODUCTS <br />ANTENNA SUPPORTING POLE IS UNDER A SEPARATE CONTRACT. THE CONTRACTOR, SHALL 1. MATERIAL <br />ASSIST ANTENNA INSTALLATION SUB -CONTRACTOR IN TERMS OF COORDINATION AND SITE <br />ACCESS. ERECTION SUB -CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF A. STRUCTURAL STEEL MEMBERS: ASTM A572, GRADE 50 <br />PERSONNEL AND PROPERTY FROM HAZARDOUS EXPOSURE TO OVERHEAD DANGERS. B. STRUCTURAL TUBING: ASTM A500, GRADE B <br />C. PIPE: ASTM A53, TYPE E OR S, GRADE B <br />GENERAL CONTRACTOR SHALL PROVIDE AT THE PROJECT SITE A FULL SET OF D. BOLTS, NUTS, AND WASHERS: ASTM A325 <br />CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR E. ANCHOR BOLTS: ASTM A307 <br />CLARIFICATIONS FOR THE USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. F. WELDING MATERIALS: AWS D1.1, TYPE REQUIRED FOR <br />MATERIALS BEING WELDED <br />DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR <br />MODIFICAIIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS, AND SUCH <br />MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SCOPE OF WORK. <br />THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING <br />IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION UPON <br />COMPLETION OF WORK. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE <br />OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. <br />CONTRACTOR SHALL ENSURE THE GENERAL WORK AREA IS KEPT CLEAN AND HAZARD FREE <br />DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE <br />EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY, PREMISES SHALL BE LEFT <br />IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE, <br />THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, REGULATIONS <br />AND SAFETY REGULATIONS, ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL <br />AUTHORITIES, AND ANY UTILITY COMPANIES' REGULATIONS AND DIRECTIVES. <br />THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF <br />WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR <br />IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES <br />TO REPRESENTATIVE. ANY MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND <br />SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING THE PROJECT <br />AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. <br />CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE <br />TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. <br />VERIFICATION THAT EXISTING TOWER/POLE/STRUCTURE CAN SUPPORT THE PROPOSED <br />ANTENNA, COAX & ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. <br />SPECIAL INSPECTIONS & STRUCTURAL OBSERVATIONS SHALL BE REQUIRED FOR ALL HIGH <br />STRENGTH NUTS & BOLTS & ALL OTHER HIGH STRENGTH BOLTED CONNECTIONS & AS <br />OTHERWISE REQUIRED BY 2015 IBC CHAPTER. 17. <br />ITEMS TO BE INSPECTED SHALL INCLUDE BUT NOT BE LIMITED TO: <br />1. HIGH STRENGTH BOLTS (REFER TO STRUCTURALS). <br />2. CONCRETE EMBEDDED BOLTS (REFER TO STRUCTURALS). <br />3. OTHER HIGH STRENGTH STEEL CONNECTION COMPONENTS (REFER TO STRUCTURALS). <br />SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 110 & 1704 SHALL BE PERFORMED (AS <br />REQUIRED) BY QUALIFIED TESTING AGENCY APPROVED BY THE <br />ARCHITECT/ENGINEER. SPECIAL INSPECTION AGENCY SHALL BE RETAINED BY PROJECT <br />OWNER OR THEIR RESPONSIBLE CHARGE. ARCHITECT, ENGINEER OF RECORD, & BUILDING <br />DEPARTMENT SHALL RECEIVE COPIES OF ALL INSPECTION & TEST RESULTS. REFER TO <br />DOCUMENTS FOR SPECIFIC INFORMATION. <br />ALL A36 THREADED ROD & U-BOLTS SHALL BE TIGHTENED TO AISC SNUG REQUIREMENTS <br />THE SNUG TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES <br />IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW IMPACTS OF AN <br />IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. <br />A36 NUT & BOLT TIGHTENING DOES NOT REQUIRE SPECIAL INSPECTION. <br />A325 &/OR A490 NUTS & BOLTS TIGHTENING REQUIRE SPECIAL INSPECTION. <br />ALL BOLTS FOR EQUIPMENT SUPPORT FRAMES & ALL OTHER STRUCTURES <br />MOUNTED/CONNECTED TO POLES, TOWERS, PARAPETS, ETC. SHALL BE A325 HIGH <br />STRENGTH (OR A490 HIGH STRENGTH AS REQUIRED) UNO. <br />TIGHTEN ALL BOLTS SUPPORTING ALL ANTENNAS, RRUS, OVPS, ETC., TO AISC SNUG <br />REQUIREMENTS. <br />� awl -4111"leml <br />G. GROUT: NON -SHRINK TYPE, PREMIXED <br />COMPOUND CONSISTING OF <br />NONMETALLIC AGGREGATE, CEMENT, <br />WATER REDUCING AND PLASTICIZING <br />ADDITIVES, CAPABLE OF DEVELOPING <br />A, MINIMUM COMPRESSIVE STRENGTH <br />OF 7000 PSI AT 28 DAYS. <br />H. SHOP AND TOUCH-UP PRIMER: SSPC 15, TYPE 1, RED OXIDE <br />L TOUCH-UP PRIMER FOR GALV. <br />J. SURFACES: ZINC RICH TYPE <br />2, FABRICATION <br />CONTINUOUSLY SEAL JOINTED MEMBERS BY CONTINUOUS WELDS. GRIND <br />EXPOSED WELDS SMOOTH. <br />3. FINISH <br />A. PREPARE STRUCTURAL COMPONENT SURFACES IN ACCORDANCE WITH SSPC <br />SP-1 TO SP-10 PROCEDURES. <br />B. STRUCTURAL STEEL MEMBERS SHALL BE HOT DIPPED GALVANIZED. <br />PART 3 - EXECUTION <br />1. EXAMINATION AND PREPARATION: VERIFY THAT THE FIELD CONDITIONS ARE <br />ACCEPTABLE. <br />2. ERECTION: <br />A. ALLOW FOR ERECTION LOADS. PROVIDE TEMPORARY BRACING TO MAINTAIN <br />FRAMING IN ALIGNMENT UNTIL COMPLETION OF ERECTION AND <br />INSTALLATION OF PERMANENT BRIDGING AND BRACING. <br />B. FIELD WELD COMPONENTS INDICATED ON SHOP DRAWINGS. <br />C. DO NOT FIELD CUT OR ALTER STRUCTURAL MEMBERS WITHOUT APPROVAL C <br />THE ARCHITECT/ENGINEER. <br />D. AFTER ERECTION, TOUCH-UP WELDS, ABRASIONS, AND SURFACES NOT SHOP <br />PRIMED OR GALVANIZED WITH TOUCH-UP PRIMERS AS SPECIFIED UNDER <br />SECTION 05000,-METALS, PART 2 - PRODUCTS, H & is SURFACES TO BE IN <br />CONTACT WITH CONCRETE NOT INCLUDED. <br />3. FIELD QUALITY CONTROL: <br />FIELD INSPECTION OF MEMBERS, CONNECTIONS, WELDS AND TORQUING. <br />TELECOMMUNICATIONS WIRING COMPONENTS <br />(COAXIAL ANTENNA CABLE) <br />1 GENERAL <br />A. ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO WORK SHALL <br />BE NEW AND OF STANDARD COMMERCIAL QUALITY. <br />B. CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER <br />TO GENERAL CONDITIONS FOR THE LIST OF OWNER FURNISHED EQUIPMENT, <br />MATERIALS AND SUPPLIES FOR THESE ITEMS). THE CONTRACTOR IS <br />RESPONSIBLE FOR PICKUP AND DELIVERY OF ALL SUCH MATERIALS. <br />C. ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT DOCUMENTS <br />SHALL BE SUPPLIED BY THE CONTRACTOR. <br />2. MATERIALS: <br />A. COAXIAL CABLE: <br />a. INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS AND <br />EQUIPMENT PER MANUFACTURER'S RECOMMENDAT IONS WITH COAXIAL <br />CABLES SUPPORTED AT NO MORE THAN 3'-0" O.C. WEATHERPROOF ALL <br />CONNECTORS BETWEEN THE ANTENNA AND EQUIPMENT PER <br />MANUFACTURERS' REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE <br />(3) FEET IN EXCESS OF EQUIPMENT LOCATION UNLESS OTHERWISE <br />STATED. <br />b. ALL COAX RUN LENGTHS GREATER THAN 143 FEET SHALL BE 1-5/8" AND <br />IN LENGTH LESS THAN OR EQUAL TO 143 FEET SHALL BE 7/8". <br />3. ANTENNA AND COAXIAL CABLE GROUNDING <br />A. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS <br />OF COAXIAL CABLE (NOT WITHIN BENDS) <br />4. COAXIAL CABLE IDENTIFICATION <br />A. TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF ANTENNA CABLING, <br />PLASTIC TAGS SHALL BE USED AT THE FOLLOWING LOCATIONS-. <br />a. FIRST LOCATION IS AT THE END OF THE COAX NEAREST THE ANTENNA <br />(WHERE THE COAXIAL CABLE AND JUMPER ARE CONNECTED). <br />b. SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER NEAR THE <br />WAVEGUIDE ENTRY PORT. <br />B. USE ANDREW CABLE TIES (PT.# 27290) TO SECURE IDENTIFICATION TAGS. <br />5. TESTING <br />VERIZON WIRELESS SHALL PROVIDE AN INDEPENDENT TESTING AGENCY TO PERFORM THE <br />COAXIAL SWEEP TEST & REPORT. THE CONTRACTOR IS TO PROVIDE CLIMBER / QUALIFIED <br />PERSONNEL TO ASSIST IN ANY REPAIRS AND WEATHERPROOFING ONCE THE TEST IS <br />COMPLETE. THE CONTRACTOR IS TO PROVIDE VERIZON WIRELESS A MINIMUM OF 48 <br />HOURS NOTICE PRIOR TO THE TIME OF THE SWEEP TEST. <br />ELECTRICAL MOTES: <br />INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED <br />IN COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE LAWS, RULES <br />AND REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, <br />AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, LC.E.A. S651 -401 , LC.E.A. <br />P81570, & LOCAL PUD. <br />PROVIDE A, METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER <br />FURNISHED BACK BOARD. <br />UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, <br />TYPE 1, CONFORMING TO UL ARTICLE 651 : WESTERN PLASTICS OR CARTON <br />MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT SEALED T PIPE: SOLVENT, <br />WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" TYPE <br />WITH A 24" MINIMUM RADIUS, ALL CONDUIT UNDER ROADS SHALL BE RGS, (OR PVC <br />ENCASED IN 8"X18" RED CONCRETE DUCTBANK). <br />CONDUIT USED INDOORS SHALL BE E.M. T ., AND RIGID GALVANIZED STEEL FOR OUTDOORS. <br />COUPLINGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW <br />FITTINGS ARE NOT PERMITTED. FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL <br />CONDUIT. <br />WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL <br />BE NO SPLICES ALLOWED. PROVIDE HDPE PULLING HAND HOLES AS NEEDED. <br />CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING <br />AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. <br />GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE <br />GRADE INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE -LUG COMPRESSION TYPE. <br />ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO PERMANENT <br />EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE, CARE SHALL BE <br />TAKEN TO REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE <br />GALVANIC CORROSION. ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH <br />ANTI -CORROSIVE AGENT SUCH AS "NO-OXY", "NOAOLX" OR "PENETROX". VERIFY <br />PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED ON <br />GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL. <br />ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS <br />LPS-3 OR AS PER NOTE 6 ABOVE. <br />ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, <br />DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH BOX. <br />CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL TVSS, <br />CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND <br />UTILITIES. WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO <br />AVOID DAMAGE. CONTACT ALL UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC <br />ROW. <br />VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.LC, RATING OF THE <br />PROVIDED EQUIPMENT SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE <br />ENTRANCE SWITCH AND CONFIRM LOWERING OF AIC TO ACCEPTABLE LEVELS. <br />UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON <br />PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID <br />PURPOSES ONLY. <br />CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK f <br />MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND <br />SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL <br />ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), <br />TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY <br />COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. <br />�t1�11�T�11��7LCs�7 <br />1. 1ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN <br />AND CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT <br />ACCESS TO EQUIPMENT IS NOT BLOCKED. <br />3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND <br />UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN . THE <br />GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. <br />4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD) <br />5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED <br />USING TWO (2) HIGH PRESS CRIMPS. <br />6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & <br />HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. <br />7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION <br />RESISTANT MATERIAL. <br />8. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS <br />OTHERWISE INDICATED. <br />9. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8" 0 10-FT. <br />LONG (OR NOTED OTHERWISE ON PLANS), AND SHALL BE DRIVEN VERTICALLY WITH THEIR <br />TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. <br />10. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK <br />TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. <br />1 1 . USE OF 90 BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED <br />WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. <br />12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM <br />BELOW THE FROST LIME. <br />13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'0" FROM <br />EQUIPMENT CONCRETE PAD, SPREAD FOOTING, OR FENCE. <br />14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD <br />GALVANIZED SPRAY, <br />15, OBSERVE N,E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE <br />GROUNDING <br />16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S <br />RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) <br />17. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 <br />OHMS. <br />18. CONTRACTOR TO VERIFY CURRENT GROUNDING STANDARDS PRIOR TO CONSTRUCTION <br />k <br />CA.$ <br />ASSOCIATES <br />19401 40TH AVE. W., SUITE 304 <br />LYNNWOOD, WA 93036 <br />PHONE: (425) 740-6392 <br />WWW.CAMPASSOC.COM <br />SKS <br />12/27/18 <br />ISSUED FOR PERMIT <br />SKS <br />12/20/18 <br />ISSUED FOR PRELIM REVIEW <br />