Laserfiche WebLink
PROPOSED ANTENNA / COAX SCHEDULE <br />SECTOR <br />POSITION <br />ANTENNA TYPE <br />ANTENNA TIP <br />HEIGHT (±) <br />ANTENNA <br />SIZE (±) <br />AZIMUTH <br />MECHANICAL <br />DOWNTILT <br />NUMBER/TYPE RUNS <br />LENGTH <br />1 (ALPHA) <br />1 <br />(P) 850—CDMA 850/PCS—LTE <br />128'-0" <br />8'-0" <br />0° <br />0° <br />I(E) 6x12 HYBRID & <br />2 15" COAX CABLE <br />±50' <br />1 (ALPHA) <br />2 <br />(P) 700/850/AWS—LTE <br />128'-0" <br />8'-0" <br />0° <br />0° <br />2 (BETA) <br />1 <br />(P) 850—CDMA 850/PCS—LTE <br />128'-0" <br />8'-0" <br />90° <br />0° <br />1(E) + 1(P) 6x12 HYBRID & <br />2(E) A" COAX CABLE <br />+80' <br />2 (BETA) <br />2 <br />(P) 700/850/AWS—LTE <br />128'-0" <br />8'-0" <br />90' <br />0° <br />3 (GAMMA) <br />1 <br />(P) 850—CDMA 850/PCS—LTE <br />128'-0" <br />8'-0" <br />180' <br />0° <br />1(E) + 1(P) 6x12 HYBRID & <br />2(E) 18" COAX CABLE <br />±95' <br />3 (GAMMA) <br />2 <br />(P) 700/850/AWS—LTE <br />128'-0" <br />8'-0" <br />180° <br />0° <br />4 (DELTA) <br />1 <br />(P) 700/850/PCS—LTE <br />128'-0" <br />8'-0" <br />270° <br />0° <br />1(P) HYBRID CABLE THIS <br />SECTOR <br />±160' <br />4 (DELTA) <br />2 <br />(P) 700/850/AWS—LTE <br />128'-0" <br />8'-0" <br />270° <br />0° <br />GENERAL NOTES <br />1. VERIFY EACH COAXIAL CABLE LENGTH, DIAMETER, ROUTING, & ALL MOUNTING <br />APPURTENANCES WITH OWNER PRIOR TO ORDER. <br />2. MAXIMUM COAXIAL CABLE LENGTH HAS BEEN ESTIMATED WITH CORRESPONDING <br />CABLE b ON THE TABLE TO THE RIGHT. THIS CABLE LENGTH IS APPROXIMATE <br />& IS TO BE USED FOR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTHS MAY <br />VARYFROM ESTIMATED MAXIMUM LENGTH & MUST BE VERIFIED. <br />3. TAG ALL MAIN CABLES AT (2) LOCATIONS: <br />A — AT ANTENNAS <br />B — INSIDE EQUIPMENT ROOM <br />4, EACH COAX SHALL BE SUPPORTED USING EXISTING ROUTE. <br />5. EACH COAX SHALL BE GROUNDED AT (2) LOCATIONS; ANTENNA, & EQUIPMENT. <br />SCOPE OF WORK: <br />REMOVE: 7 (E) PANEL ANTENNAS. <br />REMOVE: 6 (E) DIPLEXERS (2/SECTORS 1, 2, & 3). <br />REMOVE: 4 (E) RRUS-11 813 W/A-2 UNIT (1/SECTOR) <br />REMOVE: 7 (E) RRUS-32 <br />INSTALL: 1 (P) ANTENNA MOUNT AT SECTOR 4. <br />INSTALL: 8 (P) ANTENNAS (2/SECTOR). <br />INSTALL: 4 (P) RRUS-4449 B13/B5 (1/SECTOR). <br />INSTALL: 4 (P) RRUS-8843 B662/B2 (1/SECTOR). <br />NO SCOPE OF WORK AT EQUIPMENT (INSIDE (E) SHELTER). <br />2&3 (P) VZW ANTENNA, T <br />A-4.0 (2/SECTOR, 8 TOT, <br />#2 (P) <br />850/AWS <br />(E) AZIMUTH <br />VERIFY/PROVII <br />150LBS BALLAST BL( <br />#1 (P) <br />850/PCS <br />(E) AZIMUTH <br />VERIFY/PROVI[ <br />150LBS BALLAST BL( <br />1 <br />n n 1(Pl ANITFNINiA NA( <br />PROPOSED ANTENNA P <br />4 <br />SCALE: 3/4" = 1'-0" (22x34), 3/8" = V-0" (11 x17) <br />(E) VZW SLI <br />5 (F <br />A-4.0 B66, <br />(E) <br />/EQUIPMENT <br />LAN (DELTA) <br />PROPOSED ANTENNA PLAN <br />3 SCALE: 3/8" = V-0" 1 " = 1'- 17 (22x34), 3/ " 11 6 0 ( x ) <br />VERIFY/PROVIDE 5 (24"x24"x3") <br />CONCRETE (150LBS EACH) <br />BALLAST BLOCKS REUSE (E) <br />CLAMPS TO SECURE (E) TRAYS <br />(E) (E) VZW SLEEPER <br />(E) VZW ANTENNA <br />/EQUIPMENT MOUNT TYP. <br />(P) VZW RRUS-8843 B66A/132, 5 <br />TYP. (1/SECTION, 4 TOTAL) <br />4 <br />(P) VZW RRUS-4449 1313/135, <br />TYP. (1 /SECTOR, 4 TOTAL) <br />(E) VZW DC-3315 OVP THIS <br />SECTOR MOUNTED TO (E) MOUNT <br />VERIFY/PROVIDE 5 <br />150LBS CONCRETE <br />BALLAST BLOCKS <br />(E) VZW HYBRID ROUTE <br />1N (E) CABLE TRAY <br />0 <br />J 0 <br />o;,� <br />� <br />o;l� <br />C <br />�cn I S <br />0- Q <br />U I S <br />O <br />I <br />00 O I � <br />SECTOR 3 <br />0 N <br />� Q <br />' <br />L IN <br />' <br />(GAMMA) <br />w <br />W <br />GAMMA) <br />0 <br />4 <br />NORTH <br />8 12 <br />VERIFY/PROVIDE 37 (12"X16"X24") <br />CONCRETE (35LB EACH) BALLAST BLOCKS. <br />EVENLY DISTRIBUTE THE BLOCKS IN (E) <br />BALLAST TRAYS <br />(P) VZW RRUS-4449 1313/135, 4 <br />TYP. (1 /SECTOR, 4 TOTAL) <br />(E) VZW DC-3315 OVP <br />MOUNTED ON (E) MOUNT <br />(1 /SECTOR, 4 TOTAL) <br />(E) VZW ANTENNA/EQUIPMENT MOUNT <br />ON (E) FRAME ON (E) SLEEPERS, <br />TYP. (1/SECTOR, 4 TOTAL) <br />'P) VZW ANTENNA, TYP. 2&3 <br />'2/SECTOR, 8 TOTAL) <br />,E) ROOF PARAPET <br />4 <br />i <br />0 <br />(P) VZW ANTENNA, TYP. <br />2&3 (2/SECTOR, 8 TOTAL) <br />A-4.0 <br />(E) VZW ANTENNA/ — <br />EQUIPMENT MOUNT, TYP: <br />(E) VZW DC-3315 SURGE — <br />PROTECTOR/OVP, TYP. <br />(1/SECTOR, 4 TOTAL) <br />4 (P) VZW RRUS-4449 <br />A-4.0 B5/B 13, TYP. <br />(1 /SECTOR, 4 TOTAL) <br />NOTE: - A <br />PROPOSED ANTENNAS MOUNTS AND <br />EQUIPMENT SHALL BE PAINTED TO <br />Q MATCH EXISTING SITE CONDITIONS. rm <br />O ° <br />u LLJ1O Wi0 <br />O _ O J <br />Ln 0 0 <br />00 (n <br />n[ I SECTOR 1 Q Q <br />IIN <br />ow o (ALPHA) <br />N � w <br />--- - - co <br />- O , <br />ii11 ii1' 4 <br />(E) VZW ANTENNA/ <br />EQUIPMENT FRAME TYP. <br />(P) VZW RRUS-8843 5 <br />B66A/B2, TYP. <br />(1 /SECTOR, 4 TOTAL) <br />(E) VZW CABLE TRAY <br />I <br />— (E) VZW SLEEPER, TYP. <br />VERIFY/PROVIDE 37 (12"X16"X24") CONCRETE <br />(35LB EACH) BALLAST BLOCKS. EVENLY <br />DISTRIBUTE THE BLOCKS IN (E) BALLAST TRAYS <br />PROPOSED ANTENNA PLAN (ALPHA) <br />1 <br />SCALE: 3/8" = 1'-O" (22x34), 3/16" = V-0" (11x17) <br />(E) ROOF PARAPET <br />(E) VZW CABLE TRAY <br />(E) VZW EQUIPMENT <br />/ANTENNA MOUNT ON <br />(E) FRAME <br />(E) VZW SLEEPER, TYP. <br />4 (P) VZW RRUS-444� <br />A-4.0 B 13/135, TYP <br />(1 /SECTOR, 4 TOTAL; <br />2&3 (P) VZW ANTENNA, TYP. <br />A-4.0 (2/SECTOR, 8 TOTAL) <br />(E) VZW DC-3315 OVF <br />MOUNTED ON (E) MOUNI <br />VERIFY/PROVIDE 37 (12"X16"X24"; <br />CONCRETE (35LB EACH) BALLAST <br />BLOCKS. EVENLY DISTRIBUTE THE <br />BLOCKS IN (E) BALLAST TRAY <br />5 (P) VZW RRUS-884- <br />A-4.0 1366/132 TYP <br />(1 /SECTOR, 4 TOTAL, <br />NORTH <br />12 PROPOSED ANTENNA PLAN (BETA) <br />2 <br />SCALE: 3/8„= 1 0 (22x34), 3/16„ 1 0 (11 x17) <br />R <br />NORTH <br />4 8 12 <br />850—CDMA <br />5—LTE <br />WITH 90 <br />(E) VZW ANTENNA/EQUIPMENT MOUNT <br />ON (E) FRAME ON (E) SLEEPERS, <br />TYP. (1/SECTOR, 4 TOTAL) <br />700/ <br />S—LTE <br />1UTH 90 <br />=CTOR 2 <br />(BETA) <br />A-� <br />�� I <br />NORTH <br />0 4 8 12 PROJECT NUMBER <br />20171668987 <br />SEA <br />DEADWATER <br />S L89PH <br />( <br />1602 HEWITT AVE <br />EVERETT WA, 98201 <br />(((I: <br />CAMP+ <br />ASSOCIATES <br />19401 40TH AVE. W., SUITE 304 <br />LYNNWOOD, WA 98036 <br />PHONE: (425) 740-6392 <br />WWW.CAMPASSOC.COM <br />PROJECT MANAGER: EJC <br />PREPARED BY: SKS <br />APPROVED BY: GJv <br />SKS <br />12/27/18 <br />ISSUED FOR PERMIT <br />SKS <br />12/20/18 <br />ISSUED FOR PRELIM REVIEW <br />PLAN REVIEWERS SIGNATURE <br />PROFESSIONAL STAMP <br />— 12346 <br />/ 9 J. VITALE <br />STATE F WASHINGTON <br />1/9/2019 <br />SHEET NAME <br />PROPOSED <br />ANTENNA PLANS & <br />SCHEDULE <br />