co <br />M <br />F_ <br />z <br />M <br />LU <br />�a <br />z <br />z <br />0 <br />M <br />z <br />ca <br />0 <br />LU <br />C) <br />C) <br />CA <br />w <br />co <br />M <br />�I <br />LU <br />zre <br />L <br />ry <br />M <br />Ian <br />GENERAL :(I?I.ILT;JI<AI IdUIFS; <br />(FOR SUBSTATION CONCRETE SLAB ON SHEET C2.9 <br />1. THESE NOTES CONTAIN GENERAL INFORMATION AND ARE NOT COMPLETE FOR CONSTRUCTION PURPOSES. <br />CONTRACTOR SMALL VERIFY INFORMATION GIVEN HERE WITH SPECIFICATIONS AND OTHER DOCUMENTS <br />AND BRING ANY CONFLICTS TO THE ATTENTION OF THE PORT BEFORE BEGINNING AFFECTED WORK, <br />THE ENGINEER WILL RESOLVE ANY SUCH CONFLICT. <br />2. ALL DIMENSIONS AND DETAILS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO FABRICATION AND <br />CONSTRUCTION. <br />1 ALL SHOP DRAWINGS FOR REINFORCING STEEL AND STRUCTURAL STEEL SHALL BE SUBMITTED TO, AND <br />REVIEWED BY, THE ENGINEER PRIOR TO FABRICATION. <br />49 VERTICAL DATUM: SEE SHEET G3,10 <br />5. THE FOLLOWING REFERENCE DOCUMENTS WERE UTILIZED IN THE DEVELOPMENT OF THESE DRAWINGS: <br />A. GEOTECHNICAL ENGINEERING DESIGN STUDY, PORT OF EVERETT — SOUTH TERMINAL WHARF AND <br />ELECTRICAL UPGRADES — PHASE 2, EVERETT, WA BY HART CROWSER, DATED DECEMBER 6, 201I <br />CODES AND <br />1, STRUCTURAL <br />STANDARDS: <br />A. ALL METHODS AND MATERIALS SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE, 2015 <br />EDITION, AS AMENDED AND ADOPTED BY THE CITY OF EVERETT. <br />B. REINFORCED CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 <br />99SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 318 "BUILDING CODE REQUIREMENTS FOR <br />STRUCTURAL CONCRETE". <br />f' i.�,.... T <br />1. REINFORCING STEEL <br />A. ALL REINFORCING STEEL SHALL BE DEFORMED STEEL BARS CONFORMING TO ASTM A615 -ORAL E <br />60, EXCEPT AS NOTED, <br />B. LAP ALL REINFORCING BARS AS NOTED ON THE DRAWINGS. DEFORMED BAR LAP SPLICES SHALL <br />CONFORM TO THE FOLLOWING, UNLESS OTHERWISE SHOWN, <br />BAR SIZE <br />f'c 4000 PSI <br />TOP BARS <br />OTHER BARS <br /># <br />29G894 <br />29-1 99 <br />5 <br />S-94 <br />29m 79i <br />0 <br />4)4 <br />39 -199 <br />7 <br />5'_ 10" <br />4901399 <br />#8 <br />6 Al) <br />59G 299 <br />9 <br />- <br />7 _799 <br />-. <br />5-1091 <br />1 0 <br />81-6 9 <br />-. 69-799 <br />11 <br />9- 99 <br />79_Y99 <br />NOTES: <br />1 o LENGTHS ARE BASED ON CLASS, , 99B989 CASE 1 <br />SPLICES (MAX OF 50% OF BARS SPLICED AT ONE <br />LOCATION. <br />2a TOP BARS ARE DEFINED AS ANY HORIZONTAL BAR <br />PLACED SUCH THAT MORE THAN 12" OF FRESH <br />CONCRETE IS CAST IN THE MEMBER BELOW THE <br />BAR IN ANY SINGLE POUR, <br />3. STAGGER ALL LAP SPLICES IN ADJACENT BARS BY <br />ONE LAP LENGTH +1'-0" MINIMUM. <br />4, NO MORE THAN 50% OF THE REINFORCING BARS <br />IN ANY LAYER SHALL BE SPLICED AT ONE <br />LOCATION. . <br />Ca MECHANICAL SPLICES SHALL DEVELOP AT LEAST 125 PERCENT OF THE YIELD STRENGTH OF THE <br />BAR IN TENSION. <br />D. REINFORCING SHALL BE SUPPORTED AS SPECIFIED BY THE PROJECT SPECIFICATIONS AND THE <br />CRSI "MANUAL OF STANDARD PRACTICE, 99(MSP)o REINFORCING STEEL SHALL BE DETAILED IN <br />ACCORDANCE WITH' ACI DETAILING MANUAL,89 ACI SP-66o <br />16015th Avenue, Suite 1300 <br />Seattle, Washington 10! <br />(206) 382-0600 Fax (206) 382-0500 <br />PROJECT NO. 1600120 <br />2. CAST —IN --PLACE CONCRETE MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS <br />k CAST —IN —PLACE CONCRETE FOUNDATION 4,500 PSI <br />3, ALL EXPOSED CORNERS SHALL. BE CHAMFERED 3/4 IN. <br />4, CONCRETE MIX SHALL HAVE A MAXIMUM WATER CEMENT RATIO OF 0.4O UNLESS NOTED OTHERWISE. <br />SEE SPECIFICATIONS. <br />5. ALL CONCRETE SHALL BE AIR ENTRAINED AS REQUIRED BY ACI 318 FOR THE NOMINAL MAXIMUM <br />AGGREGATE SIZE USED AND THE EXPOSURE CLASSIFICATION BELOW. <br />6e CONCRETE MIX SHALL BE SELECTED IN CONSIDERATION OF THE FOLLOWING EXPOSURE CATEGORIES IN <br />ACCORDANCE WITH ACI 31 o. F2, SO, WO, Cl, <br />SPECIAL INSPECTION SCHEDULE <br />ESTABLISHED PER 2015 IBC SECTION 109 & CHAPTER 17 <br />ITEM <br />CONTINUOUS <br />PERIODIC <br />COMMENTS <br />INSPECTION <br />INSPECTION <br />Soils-- <br />Cradinay excavation & fill <br />By Ceotechoical enineer <br />Final foundation Preparation <br />-y <br />Ceotechnical engineer <br />Concrete <br />- <br />�ei�sfor�in lacernent <br />X <br />Reinforcing w Ic g <br />X <br />Reinforcing oouPling - <br />X <br />X <br />Ref. note 4 <br />Anchor bolts & inserts <br />- X <br />-Preparation of teat 8 ecie ens <br />X <br />Concrete placement <br />X <br />Adhesive anchor placement I <br />X <br />I Ref. note 5 <br />Expansion anchor placement <br />X <br />Rif. note 5 <br />NOTES:INSPECTION SCHEDULE <br />1 o THE ITEMS CHECKED WITH AN 99X99 SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17 BY <br />A CERTIFIED SPECIAL INSPECTOR FROM AN ESTABLISHED TESTING AGENCY, FOR MATERIAL SAMPLING <br />AND TESTING REQUIREMENTS, REFER TO PROJECT SPECIFICATIONS, THE STRUCTURAL NOTES AND <br />THE NOTES BELOW. THE TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND <br />INSPECTION REPORTS DIRECTLY TO THE ARCHITECT, ENGINEER, CONTRACTOR AND BUILDING <br />OFFICIAL, ANY MATERIALS WHICH FAIL TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY <br />BE BROUGHT 'TO THE ATTENTION OF THE ARCHITECT. SPECIAL INSPECTION TESTING REQUIREMENTS <br />APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. INSPECTION AND TESTING REQUIREMENTS <br />FOR SYSTEMS DESIGNED BY OTHERS SHALL BE DEFINED BY THE REGISTERED DESIGN <br />PROFESSIONAL RESPONSIBLE FOR THEIR DESIGN, EXCEPT THAT THE INSPECTION REQUIREMENTS <br />SHALL NOT BE LESS THAN SPECIFIED IN .THIS SCHEDULE. <br />2. PROVIDE SPECIAL INSPECTION PER SECTION 1704 OF THE INTERNATIONAL BUILDING CODE AS <br />AMENDED AND ADOPTED BY THE CITY OF TACOMA. THE SPECIAL INSPECTION AGENCY( AND THE <br />SPECIAL INSPECTORS SHALL &E CERTIFIED THROUGH TIME WASHINGTON ASSOCIATION OF BUILDING <br />OFFICIALS (WABO) CERTIFICATION PROGRAM FOR THE INSPECTIONS TO BE PERFORMED, THE SPECIAL <br />INSPECTION AGENCY WILL BE MIRED BY AND AT THE EXPENSE OF THE OWNER AND WILL BE <br />RESPONSIBLE TO THE BUILDING OFFICIAL FOR THE AREAS OF SPECIAL INSPECTION APPLICABLE TO <br />THE PROJECT. <br />3. CONTINUOUS SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON THE SITE AT ALL <br />TIMES OBSERVING THE WORK REQUIRING SPECIAL INSPECTION (IBC 1702). PERIODIC SPECIAL <br />INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT TIME INTERVALS NECESSARY TO <br />CONFIRM THAT ALL WORK REQUIRING SPECIAL INSPECTION IS IN COMPLIANCE. <br />4, CONTINUOUS INSPECTION IS REQUIRED FOR INSTALLATION OF COUPLERS. PERIODIC INSPECTION MAY <br />BE USED FOR VERIFICATION 01. COUPLER MATERIALS. <br />5, INSPECTION OF DRILLED CONCRETE ANCHORS, INCLUDING UNDERCUT, EXPANSION AND ADHESIVE <br />GROUTED ANCHORS, SHALL INCLUDE VISUAL VERIFICATION ANCHOR TYPE AND DIMENSIONS, OF <br />DRILLED HOLE DEPTH, SPACING, EDGE DISTANCES, HOLE CLEANING, ANCHOR EMBEDMENT AND <br />TIGHTENING TORQUED FOR GROUTED ANCHORS, GROUT INSTALLATION SHALL BE OBSERVED AND <br />GROUT PRODUCT SPECIFICATION AND PREPARATION SHALL BE VERIFIED, <br />PROJECT ENGINEER: <br />SCALE: <br />AS SHOWN <br />DATE: <br />12/08/2017 <br />CHECKED BY: <br />No WATSON <br />IF SHEET IS LESS THAN 22X34 <br />REDUCE SCALE ACCORDINGLY <br />