Laserfiche WebLink
F_ <br />z <br />LU <br />) <br />W <br />�I <br />z <br />UA- <br />U_ <br />U_ <br />0- <br />CA <br />C) <br />m <br />C) <br />Uj <br />a_ <br />0 <br />I- <br />w <br />z <br />F_ <br />w <br />ry- <br />w <br />GENERALTES® <br />1. THESE NOTES CONTAIN GENERAL INFORMATION AND ARE NOT COMPLETE FOR CONSTRUCTION <br />PURPOSES. CONTRACTOR SHALL VERIFY INFORMATION GIVEN HERE WITH SPECIFICATIONS AND OTHER <br />DOCUMENTS AND BRING ANY CONFLICTS TO THE ATTENTION OF THE PORT BEFORE BEGINNING <br />AFFECTED WORK. THE ENGINEER WILL RESOLVE ANY SUCH CONFLICT. <br />2. ALL DIMENSIONS AND DETAILS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO FABRICATION AND <br />CONSTRUCTION. <br />3. ALL SHOP DRAWINGS FOR PRECAST CONCRETE ELEMENTS, REINFORCING STEEL AND MISCELLANEOUS <br />STEEL SHALL BE SUBMITTED TO, AND REVIEWED BY, THE ENGINEER PRIOR TO FABRICATION. <br />4. VERTICAL DATUM: SEE SHEET G3.1. <br />5. THE FOLLOWING REFERENCE DOCUMENTS WERE UTILIZED IN THE DEVELOPMENT OF THESE DRAWING'S: <br />A. WEYERHAEUSER COMPANY CARGO DOCK AND WAREHOUSE ADDITION, EVERETT, WASHINGTON, "AS <br />BUILT" DRAWINGS, DATED DECEMBER 8, 1978. <br />B. SOUTH TERMINAL WHARF UPGRADES FOR RO/RO, RECORD DRAWINGS, DATED SEPTEMBER 10, <br />2015 (CIP NO. 1-8----002-02, PROJECT NO. MT-ST-2014-17). <br />C. DOLPHIN BERTH IMPROVEMENTS, RECORD DRAWINGS, DATED MAY 15, 2013 (CIP NO. <br />1 -8-001 -02, PROJECT NO. MT-ST-201 1 -04). <br />D. MARINE TERMINALS FENDER PILE REPLACEMENT 2014/2015, RECORD DRAWINGS, DATED MAY 8, <br />2015 (CIP NO. 1-0-007-03, PROJECT NO. MT-P1-2014-18). <br />E. GEOTECHNICAL ENGINEERING DESIGN STUDY, PORT OF EVERETT -- SOUTH TERMINAL WHARF AND <br />ELECTRICAL UPGRADES -- PHASE II, EVERETT, WA BY HART CROWSER, DATED DEC 06, 2017. <br />F. PILE AND SUPERSTRUCTURE INVESTIGATION - SOUTH TERMINAL WHARF, PORT OF EVERETT, VVA, <br />BY ECHELON ENGINEERING, INC., DATED JULY 2017 <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT EQUIPMENT UTILIZED AND <br />CONSTRUCTION ACTIVITIES PERFORMED ON THE WHARF STRUCTURE WILL NOT OVERSTRESS ANY <br />PORTION OF THE STRUCTURE IN THE CONDITION IT IS IN AT THE TIME OF THE EQUIPMENT UTILIZATION <br />OR CONSTRUCTION ACTIVITY, ESPECIALLY AT TIMES WHEN PORTIONS OF THE WHARF HAVE BEEN <br />DEMOLISHED, VERIFICATION SHALL BE PERFORMED BY A LICENSED PROFESSIONAL ENGINEER <br />REGISTERED IN THE STATE OF WASHINGTON AND SUBMITTED TO THE PORT FOR RECORD. <br />1. STRUCTURAL <br />A. ALL METHODS AND MATERIALS SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE, 2015 <br />EDITION, AS AMENDED AND ADOPTED BY THE CITY OF EVERETT. <br />B. REINFORCED CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 <br />"SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 318 "BUILDING CODE REQUIREMENTS FOR <br />STRUCTURAL CONCRETE". <br />C. STRUCTURAL AND MISCELLANEOUS STEEL FABRICATION AND ERECTION SHALL CONFORM TO THE AISC <br />"CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" 2010. <br />D. WELDING OF STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO THE AWS D1.1, 2010. <br />E. WELDING OF REINFORCING STEEL SHALL CONFORM TO THE AWS D1.4, 2010. <br />REIN -FORCED <br />i CONCRETE,: <br />i <br />1. REINFORCING STEEL <br />A. ALL REINFORCING STEEL SHALL BE DEFORMED STEEL BARS CONFORMING TO ASTM A615-GRADE <br />60, EXCEPT AS NOTED. <br />a. ALL REINFORCING <br />STEEL TO BE WELDED <br />SHALL BE <br />ASTM A706-GRADE 60. <br />b. DOWEL BARS FOR <br />PILE TO PILE CAP CONNECTIONS <br />SHALL BE ASTM A706-GRADE 60. <br />c. ASTM A 615 GRADE 60 REINFORCEMENT <br />SHALL BE <br />PERMITTED FOR USE AS DOWEL BARS FOR <br />PILE TO PILE CAP <br />CONNECTIONS IF THE <br />FOLLOWING <br />ARE MET: <br />i. THE ACTUAL <br />YIELD STRENGTH BASED <br />ON MILL <br />TESTS DOES NOT EXCEED Fy BY MORE THAN <br />18,000 PSI <br />(RETESTS SHALL NOT EXCEED THIS VALUE BY MORE THAN AN ADDITIONAL 3000 <br />PSI); AND <br />ii. THE RATIO OF THE ACTUAL_ TENSILE <br />STRENGTH <br />TO THE ACTUAL YIELD STRENGTH IS NOT <br />LESS THAN <br />1.25 <br />1601 Sth Avenue, Suite 1300 <br />Seattle, Washington 98101 <br />(206) 382-0600 Fax (206) 382-0500 <br />PROJECT NO. 1600120 <br />B. LAP ALL REINFORCING BARS AS NOTED ON THE DRAWINGS. DEFORMED BAR LAP SPLICES SHALL <br />CONFORM TO THE FOLLOWING, UNLESS OTHERWISE SHOWN. <br />SCHEDULE <br />OF <br />MINIMUM LAP <br />SPLICE <br />AND <br />DEVELOPMENT <br />LENGTHS <br />BAR SIZE <br />f'c 5000 PSI <br />TOP <br />PARS <br />O,HER STRAIGHT BARS <br />HOOKED PARS <br />{) <br />- -7" <br />))\ <br />(21`9 <br />)) (27®`I99) <br />29®9 <br />(H99) <br />#5 <br />4)-619 <br />-r9)) <br />(3'- <br />S-5" (2)®^)) <br />(1199) <br />#6 <br />59-52 <br />(4)-2") <br />q1-2" (�L9-2)1) <br />.C-0" <br />(�9v VI) <br />4�98) <br />7 <br />7)-10" <br />(^9_^17) <br />e)^893) <br />(4)- <br />(V- <br />%8 <br />91-01) <br />11 <br />(6191-A11") <br />C-1199 (_I�1- A97) <br />hV {it)i <br />(1 5") <br />�•./99J <br />#9 <br />9 99 <br />10 - 1 <br />i9 <br />(7'-9 ) <br />) 9Y ) <br />7 -9 (6 ®0) <br />9. <br />(1 ®6 ) <br />10 <br />111-5)1 <br />(81-^)9) <br />8)-91) (62-9))) <br />(V-10) <br />#11 <br />12) 8)) <br />(lV97yaa9))) <br />9-9)9 <br />9 <br />NOTES: <br />1. LENGTHS ARE BASED ON CLASS "B", CASE 1 SPLICES (MAX OF 50% OF <br />BARS SPLICED AT ONE LOCATION. <br />2. DEVELOPMENT LENGTHS ARE SHOWN IN BRACKETS (#) <br />3. TOP BARS ARE DEFINED AS ANY HORIZONTAL BAR PLACED SUCH THAT <br />MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW <br />THE BAR IN ANY SINGLE POUR. <br />4. STAGGER ALL LAP SPLICES IN ADJACENT BARS BY ONE LAP LENGTH <br />+V-0" MINIMUM. <br />5. NO MORE THAN 50% OF THE REINFORCING BARS IN ANY LAYER SHALL BE <br />SPLICED AT ONE LOCATION. <br />6. FOR EPDXY COATED BARS, LAP SPLICE AND DEVELOPMENT LENGTHS SHALL <br />BE 1.5 TIMES THE VALUES IDENTIFIED IN THE SCHEDULE OF MINIMUM LAP <br />SPLICE AND DEVELOPMENT LENGTHS ABOVE. <br />7. DEVELOPMENT & SPLICE LENGTHS ARE APPLICABLE FOR TENSION OR <br />COMPRESSION. <br />8. FOR NON -CONTACT LAP SPLICES THE TRANSVERSE CENTER---TO-CENTER <br />SPACING OF SPLICED BARS SHALL NOT EXCEED THE LESSER OF ONE -FIFTH <br />THE REQUIRED LAP SPLICE LENGTH AND 61N, <br />C. EPDXY COATED REINFORCING BARS SHALL CONFORM TO ASTM A934. ALL CRANE BEAM AND PILE <br />CAP BOTTOM LONGITUDINAL BARS AND STIRRUPS, INCLUDING MECHANICAL COUPLERS, BUT <br />EXCLUDING PILE DOWELS AND SPIRALS SHALL BE EPDXY COATED, THE CONTRACTOR SHOULD BE <br />AWARE THAT EPDXY COATED REINFORCING BARS CONFORMING TO ASTM A934 MAY REQUIRE <br />LONGER LEAD TIMES FOR PROCUREMENT THAN BLACK BAR OR OTHER COATED REINFORCEMENT. <br />D. MECHANICAL SPLICES SHALL DEVELOP AT LEAST 125 PERCENT OF THE YIELD STRENGTH OF THE <br />BAR IN TENSION. <br />E. REINFORCING SHALL BE SUPPORTED AS SPECIFIED BY THE PROJECT SPECIFICATIONS AND THE <br />CRSI "MANUAL OF STANDARD PRACTICE, "(MSP). REINFORCING STEEL SHALL BE DETAILED IN <br />ACCORDANCE WITH" ACI DETAILING MANUAL," ACI SP-66. <br />F. ALL HORIZONTAL_ REINFORCEMENT AT DISCONTINUITIES AND CORNERS SHALL END WITH STANDARD <br />90° HOOKS IN ACCORDANCE WITH ACI SP-66, UNLESS SHOWN OTHERWISE. <br />2. CAST -IN -PLACE CONCRETE MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS <br />A. CAST--IN--PLACE CONCRETE PILE CAPS 5000 PSI <br />B. PULLRAIL AND BOLLARD FILL 5000 PSI <br />C. CAST -IN -PLACE CONCRETE CRANE BEAMS 5000 PSI <br />3. ALL EXPOSED CORNERS SHALL BE CHAMFERED 3/4 IN. <br />4. CONSTRUCTION JOINTS SHALL BE PROVIDED ONLY AS NOTED ON THE DRAWINGS AND AS SPECIFICALLY <br />PERMITTED BY THE ENGINEER, <br />5. CONCRETE MIX SHALL HAVE A MAXIMUM WATER CEMENT RATIO OF 0.40 UNLESS NOTED OTHERWISE. <br />SEE SPECIFICATIONS. <br />6. ALL CONCRETE SHALL BE AIR ENTRAINED WITH A TARGET OF 5% ± 1 1 /2% UNLESS NOTED <br />OTHERWISE IN THE SPECIFICATIONS, <br />L <br />12/08/17 <br />SK <br />ISSUED FOR DID AND PERMIT. <br />NO. <br />DATE I <br />BY <br />REVISION <br />NO. I DATE I BY <br />REVISION <br />PROJECT ENGINEER: <br />A. BERGMAN <br />DESIGNED BY: <br />S. STORY <br />DRAWN BY: <br />T. LEMONS <br />APPROVED <br />7. UNLESS NOTED OTHERWISE ON THE DRAWINGS, CONCRETE COVER SHALL BE AS FOLLOWS: <br />A. CONCRETE CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND 377 CLEAR <br />B. CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND 2" CLEAR <br />C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND 1 1 /2" CLEAR <br />1. USE OF DRILLED ADHESIVE CONCRETE ANCHORS, WHERE NOT SPECIFIED IN THE DOCUMENTS, <br />SHALL BE SUBJECT TO APPROVAL BY THE ENGINEER. <br />2. EPDXY OR ADHESIVE -TYPE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S <br />RECOMMENDATION. SPECIAL INSPECTION IS REQUIRED FOR ALL ADHESIVE ANCHORS. <br />3. ACCEPTABLE ADHESIVES ARE HILTI HIT RE 500 OR RE 500 SD OR SIMPSON SET-XP SYSTEM. ICBO <br />OR ICC REPORTS SHALL BE SUBMITTED FOR ALL ADHESIVE ANCHOR PRODUCTS. <br />RUNG- <br />1. PILES SHALL BE DRIVEN TO THE MINIMUM TIP ELEVATIONS AND REQUIRED GEOTECHNICAL CAPACITIES <br />INDICATED ON SHEET 56.1. <br />2 PILES SHALL BE 50KSI MATERIAL. SEE SPECIFICATIONS FOR PILE MATERIAL, COATING AND DRIVING <br />REQUIREMENTS. <br />MISCEL.LANEOUS STEEL: <br />1. ALL MISCELLANEOUS STEEL SHAPES AND PLATES, EXCEPT AS NOTED BELOW SHALL CONFORM TO <br />ASTM A 36, <br />2. STEEL PLATE NOTED AS GRADE 50 SHALL CONFORM TO ASTM A572, GRADE 50. <br />3. ALL HSS SHAPES SHALL CONFORM 1-0 ASTM A500, GRADE B. <br />4. ECONOMY BOLTS SHALL CONFORM TO ASTM A 307, UNLESS SPECIFICALLY NOTED OTHERWISE ON <br />THE DRAWINGS. <br />5. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM F 1554, GRADE 36 (TYPICAL), AND GRADE 105 AS <br />INDICATED ON THESE DRAWINGS. <br />6. HIGH STRENGTH THREADED BAR SHALL CONFORM TO ASTM A615, GRADE 75. <br />7. PROVIDE BLEED HOLES IN EMBEDDED PLATES AND SHAPES AT 24---IN. ON CENTER MAXIMUM UNLESS <br />NOTED OTHERWISE. <br />8. ALL MISCELLANEOUS PIPES AND SLEEVES SHALL CONFORM TO ASTM A 53, GRADE B. <br />9. HIGH STRENGTH BOLTS FOR STEEL -TO -STEEL CONNECTIONS SHALL BE ASTM A325X. <br />10. ALL NUTS SHALL BE ASTM A 563, UNLESS NOTED OTHERWISE. <br />11. ALL WASHERS SHALL BE ASTM F 436, UNLESS NOTED OTHERWISE. <br />12. ALL STEEL ITEMS SHALL BE HOT -DIP GALVANIZED AND/OR COATED IN ACCORDANCE WITH THE <br />CONTRACT SPECIFICATIONS, UNLESS NOTED OTHERWISE. <br />13. SEE THE CONTRACT SPECIFICATIONS FOR WHICH STEEL ITEMS ARE TO RECEIVE HIGH PERFORMANCE <br />COATING IN ADDITION TO GALVANIZING. <br />WELDING: <br />1. ALL WELDING SHALL BE PERFORMED BY WELDERS QUALIFIED FOR THE WELD AND POSITION SHOWN <br />IN ACCORDANCE WITH AWS AND HAVING CURRENT CERTIFICATION FROM WABO. <br />2. ALL WELDS SHALL BE PERFORMED WITH PROCEDURES PREQUALIFIED OR QUALIFIED IN ACCORDANCE <br />WITH AWS D1 .1 OR D1 ,4, <br />3. THE WELDS SHOWN ARE FOR THE FINAL CONNECTIONS. FIELD WELD SYMBOLS ARE SHOWN WHERE <br />FIELD WELDS ARE REQUIRED BY THE STRUCTURAL DESIGN. THE CONTRACTOR IS RESPONSIBLE FOR <br />DETERMINING IF A WELD SHOULD BE SHOP -WELDED OR FIELD -WELDED IN ORDER TO FACILITATE <br />THE STRUCTURAL STEEL ERECTION. <br />4. WELDING ELECTRODES SHALL BE 70 KSI STRENGTH AND SHALL BE "LOW- HYDROGEN" ELECTRODES. <br />SCALE: <br />AS SHOWN <br />DATE: <br />12/08/2017 <br />CHECKED BY: <br />S. KUEBLER <br />ACCORDINGLY'F SHEET IS LESS THAN 22x3M <br />REDUCE SCALE <br />I � � <br />I <br />SHEET NO, 58 OF 176 <br />