Laserfiche WebLink
yF i <br />- 30'-0° - 30'-0" <br />fI <br />i — <br />I I <br />—�i <br />k I - I - i - <br />� : I <br />I <br />f <br />b j fi .,.� , ,,F,t •'"`'.a '.�..."'1 k GA <br />i <br />! 1 t \ <br />r i { � __ �- -- ----•- -67 <br />- <br />'J n <br />n ! a F a j a <br />n c <br />a <br />4 n ,�AI <br />. <br />d ° n <br />_`� �_EI ;� a <br />BUILDING CODE <br />ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. THE PUBLICATIONS <br />LISTED BELOW ARE THE GOVERNING CODES AND STANDARDS AND ARE REFERENCED <br />BY THEIR BASIC DESIGNATION. IN THE CASE OF CONFLICTING REQUIREMENTS, THE BUILDING <br />CODE SHALL GOVERN. <br />APPLICABLE CODES AND STANDARDS <br />BUILDING CODE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION <br />ACI 318 AMERICAN CONCRETE INSTITUTE, "BUILDING CODE <br />REQUIREMENTS FOR STRUCTURAL CONCRETE," <br />2014 EDITION <br />ASCE 7 AMERICAN SOCIETY OF CIVIL ENGINEERS, , <br />"MINIMUM DESIGN LOADS FOR BUILDINGS AND <br />OTHER STRUCTURES," 2016 EDITION, <br />INCLUDING SUPPLEMENT NO. 1 <br />Fes; a4 d I �! -- ° a- — k i K Q CONCRETE <br />n <br />' <br />1 n f a f f MIXING BATCHING TRANSPORTING PLACING AND CURING OF ALL CONCRETE, AND SELECTION <br />� �" <br />ATIONS FOR STRUCTURAL <br />�__; OF CONCRETE MATERIALS, SHALL CONFORM TO ACI 301, SPECIFIC 0 <br />(E) 24" SOG r--- a �— T (E) 24" SOG - CONCRETE," EXCEPT AS NOTED BELOW. PROPORTIONS OF AGGREGATE TO CEMENTITIOUS <br />! C ! 1 V-3 >; PASTE SHALL BE SUCH AS TO PRODUCE A DENSE, WOR <br />KABLE MIX THAT CAN BE PLACED <br />t I \ 1 {.®s_.—._—.—._..__—�_.___.._.._..._.�..-..-e..—._ ``f`' ✓ 1 o t lam. �. "s <br />VERIFY ���i�� - U I� f ; ! I ; � ;� ; I � <br />! 1° °d r `; { 4 WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. <br />MIX DESIGNS LISTED BELOW SHALL BE SUBMITTED TO THE ARCHITECT AND APPROVED PRIOR TO <br />a USE. SELECTION OF CONCRETE MIX PROPORTIONS SHALL BE IN ACCORDANCE WITH ACI 301. <br />f I ----I ;I i i I. I _ i _ I f 4; <br />a- — f _. — — .-. a» _.. .- — ®® - — wr — —i ��-- ° L s _ — - — — .__ —— m — — _ 6 — — _.• ------------ <br />4 ®—jam n <br />,% I a, , I 7It -�; _i k ° MIX PROPORTIONS SHALL MEET OR EXCEED THE REQUIREMENTS LISTED BELOW FOR T <br />' aA"y^: -- <br />_ I HE LOCATIONS NOTED. THE MORE STRINGENT OF THE REQUIREMENTS LISTED SHALL GOVERN. <br />(E)12 SOG I I ! (E)12 SOG r - PROVIDE ASTM C150 TYPE I OR TYPE II CEMENT UNLESS NOTED OTHERWISE. THE CEMENTITIOUS <br />° N <br />12'-6 3/° i ; : ! MATERIAL CONTENT SHALL BE ADEQUATE FOR THE SPECIFIED REQUIREMENTS FOR STRENGTH, <br />EI <br />VERIFY ; �: � � `' WATER -CEMENT RATIO, DURABILITY, AND FINISH ABILITY. <br />0'-2 1(_ ---- <br />1 !% iSQ Eit3TEi i u ! VERIFY j <br />y_ ! I I - " - _ _ a �� <br />r ! I �; { -- ; e ;I C LU -- -i t-1 ISOCENTE °I MAXIMUM COMPLEMENTARY CEMENTING MATERIALS (EX. FLY ASH SLAG SILICA FUME) AS A <br />_ i ra ! , <br />I -4. <br />PERCENTAGE OF TOTAL WEIGHT OF CEMENTITIOUS MATERIAL SHALL BE50 PERCENT. FLY ASH <br />M 1 REQUIREMENTS; NOT EXCEED 3 PERCENT F TOTAL <br />! QI I SHALL MEET AST C6 8 REQU EMEN S, AND SHALL 0 0 C 0 <br />---- ---- - 1 E_-- <br />- ; -- f CEMENTITIOUS MATERIAL. WATER/CEMENT RATIO SHALL BE BASED ON TOTAL CEMENTITIOUS <br />' �, DEPRESSED(E) i i� I I_ I <br />�) 'I MATERIAL, INCLUDING COMPLEMENTARY CEMENTING MATERIALS. MAXIMUM SIZE OF <br />ON <br />AGGREGATE SHALL BE AS LISTED BELOW. <br />• � �;�° � ; � ! fir, r, C- <br />- -- - i I ° - �- (E) SOG TO BE SAWCUT! - <br />._ — __— L_ _—..— ( _ <br />�� REMOVED REWORK SLAB ALL CONCRETE USED IN HORIZONTAL SURFACES EXPOSED TO THE WEATHER SHALL CONTAIN <br />�i a I <br />�� AN ACCEPTABLE ADMIXTURE TO PRODUCE AIR -ENTRAINED CONCRETE WITH TOTAL AIR CONTENT <br />T- _-,— <br />_ - ' a 13 ; PER DETS i I <br />.__ _ !II �. r t° G I;� I I - - ; ! v ` AS NOTED IN THE CONCRETE MIX SPECIFICATION TABLE. TOLERANCE FOR AIR CONTENT SHALL <br />°" , ° ' ? ! I °a n i I In !.i g I ; BE +/-1.5 <br />J \ `\\ PERCENT AIR CONTENT SHALL BE MEASURED AT THE DISCHARGE OF THE TRUCK. <br />41 <br />IF CONCRETE IS PUMPED, AIR CONTENT SHALL BE MEASURED AT THE DISCHARGE END OF THE <br />PUMP LINE. TESTS FOR AIR CONTENT SHALL MEET ASTM C172 REQUIREMENTS. <br />I <br />L ; I E ( I ! (E) SOG T0,'BE SAWCUT <br />I ! I i------------' ! & REMOVED REWORK <br />THE CONTRACTOR SHALL DETERMINE SLUMP. EACH CONCRETE MIX SUBMITTED SHALL HAVE <br />\' I- --_ ; a i i I _-- -- -� SLAB PER DETS <br />12 d THE SLUMP SPECIFIED. SLUMP SHALL BE MEASURED AT THE DISCHARGE OF THE TRUCK. <br />--- --- ter F— _ 14 f <br />- ,., IF CONCRETE IS PUMPED SLUMP SHALL BE MEASURED AT THE DISCHARGE END OF THE PUMP <br />I i _ -_ \_ , i i I —. --__ ..� � _ { 1 <br />\ TYp n n ° ------ �- ° b a LINE. SLUMPS SHALL BE WITHIN +1 INCH AND -2 INCHES OF THE SPECIFIED SLUMP. <br />° <br />n� <br />n y n. <br />I <br />i' <br />a <br />c c c c <br />i <br />o ° <br />/-_-. <br />?��- h _ ' a ° ° - ° ° ° THE USE OF SUPER PLASTICIZERS AND WATER REDUCERS IS ALLOWED, BUT NOT REQUIRED. <br />--- - - ---= - - - ---- 4 - -- -- #�JEW-OPN�G�II4-SOG- °-- _ -, <br />ALL ADMIXTURES AL E CHLORIDE FREE UNLESS OTHERWISE APPROVEDBY THE ENGINEER. <br />7 - 7� / j� - � ,'T, - T T i_ l - i - '� _ 7-' 4— <br />T ' ' ' % ZZ7� _� LT/1�7__..��JT._�1T 1 �ZT� _� Z �L_. �Z�_ 7 TG�T . __'_. 11�� . =Z, 7�'7T �� _ ._ .. ? - - _ --- <br />rF3R� AIM A SHALL B RI NL <br />K � <br />a (E) CONC W/ 44 TOP ON ALL EDGES CONCRETE MIX SPECIFICATION TABLE <br />11 WALLS TYP <br />S1.0 I <br />f <br />NOTES: <br />1. REFERENCE FLOOR ELEVATION 140'-0", VERIFY IN FIELD. <br />2. (E) INDICATES EXISTING. STRUCTURE IS TO REMAIN AND SHALL NOT BE MODIFIED EXCEPT WHERE SPECIFICALLY NOTED. NOTIFY ENGINEER IF ADDITIONAL DEMO IS REQUIRED. <br />LEVEL 1 PARTIAL FRAMING PLAN <br />(E) CONC WALL <br />#4 @ 16" T&B, <br />HOOK AT ENDS <br />INTENTIONALLY ROUGHEN <br />JT TO 1/4" AMPLITUDE, TYP <br />SLAB STEP BEYOND <br />CV LL <br />DEPRESSED (E) SOG <br />#4 @ 16" T&B, DRILL AND <br />EPDXY W/ 8" EMBED <br />lII1II III= <br />'I Illi��lll�l- <br />H.9 <br />( <br />_LEVEL -1 <br />140'-0" (VIF) <br />--, I <br />NOTES: <br />1. REPLACE OR REPAIR BELOW SLAB VAPOR BARRIERS OR MEMBRANES. SEE ARCHITECTURAL <br />DRAWINGS FOR MORE INFORMATION. <br />SECTION <br />1/2" = 1'-0" <br />#4 @ 8" W/ STD HOOK, DRILL 611.1611 (E) SOG <br />& EPDXY W/ 8" EMBED LEVEL 1 <br />i 140'-0" (VIF) <br />it <br />i <br />"- II <br />I1 11= <br />'II1II• IIIIIIIIII��II� <br />NEW DEPRESSED INFILL SOG, <br />SEE 11/S1.0 FOR REINF <br />NOTES: <br />1. REPLACE OR REPAIR BELOW SLAB VAPOR BARRIERS OR MEMBRANES. <br />SEE ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. <br />SECTION <br />1 /2" =1'-0" <br />(10) #4 CONT, DRILL & EPDXY <br />W/ 8" EMBED AT ENDS <br />co U-� I (- <br />INTENTIONALLY ROUGHEN <br />JT TO 1/4" AMPLITUDE, TYP <br />#4 @ 16" T&B, DRILL <br />& EPDXY W/ 8" EMBED <br />#4 @ 16" T&B EW, DRILL <br />NEW CURB W/ (4) #4 & EPDXY W/ 8" EMBED — <br />CONT & #4xTL @ 16" INTENTIONALLY ROUGHEN <br />(E) SOG JT TO 1/4" AMPLITUDE, TYP <br />LEVEL 1 <br />=_140'-0" (VIF) <br />• TT N-7 Iry <br />NEW AIR DUCT PER MECH, <br />ENCASE IN 6" CONC MIN <br />NOTES: <br />1. REPLACE OR REPAIR BELOW SLAB VAPOR BARRIERS OR MEMBRANES. <br />SEE ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. <br />-;-� SECTION <br />1/2" = 1'-0" <br />U <br />co <br />(4) ADDL #4 CONT, <br />DRILL & EPDXY W/ 8" <br />EMBED AT ENDS <br />fc TEST MAX MAX AIR <br />MIN AGE W/C AGGREGATE CONTENT <br />LOCATION (PSI) (DAYS) RATIO SIZE PERCENT- <br />0 1 2 3 6 12 <br />INTERIOR SLABS 4,000 28 0.50 3/4" - <br />z <br />ON GRADE, CURBS, <br />1/4" =1'-0" <br />MECH PADS <br />REINFORCING STEEL <br />ALL REINFORCING SHALL BE NEW BILLET STOCK ASTM A615, GRADE 60, UNLESS NOTED <br />OTHERWISE, REINFORCING REQUIRED TO BE EPDXY COATED SHALL BE ASTM A775, GRADE 60, <br />UNLESS NOTED OTHERWISE. BARS SHALL BE SECURELY TIED IN PLACE WITH #16 GAGE MINIMUM <br />ANNEALED BLACK WIRE. EPDXY -COATED REINFORCING BARS SHALL BE FASTENED WITH NYLON-, <br />EPDXY-, OR PLASTIC -COATED TIE WIRE OR OTHER ACCEPTABLE MATERIALS. BARS SHALL BE <br />SUPPORTED ON CHAIRS IN ACCORDANCE WITH THE CRSI MANUAL OF STANDARD PRACTICE. <br />THE CONTRACTOR SHALL COORDINATE REINFORCING STEEL PLACEMENT DETAILS AND PROVIDE <br />TEMPLATES FOR PLACING STEEL IN CONGESTED AREAS AS NECESSARY. SHOP DRAWINGS <br />(INCLUDING PLACING PLANS AND ELEVATIONS) SHALL BE SUBMITTED TO, AND REVIEWED BY, <br />THE ARCHITECT/ENGINEER BEFORE STARTING FABRICATION. <br />(E) SOG <br />MINIMUM CAST -IN -PLACE CONCRETE COVER OVER REINFORCING STEEL, <br />Ilk�� s <br />LEVEL 1 <br />_ _ _ _ _ <br />UNLESS NOTED OTHERWISE, SHALL BE AS FOLLOWS: <br />i <br />140'-0" (FV) <br />1. CONCRETE CAST AGAINST EARTH: <br />ALL BAR SIZES: 3 INCHES <br />#4x U @ 16" STIRRUP <br />BELOW DUCT <br />2. CONCRETE EXPOSED TO EARTH OR WEATHER: <br />NEW AIR DUCT PER MECH, <br />ENCASE IN 6" CONC MIN <br />#6 BAR OR LARGER: 2 INCHES <br />#5 BAR OR SMALLER: 1 1/2 INCHES <br />3. OTHER CONCRETE: <br />SLABS: <br />#11 BARS AND SMALLER: <br />NOTES: TOP BARS: 3/4 INCH <br />BOTTOM BARS: 1 INCH <br />1. REPLACE OR REPAIR BELOW SLAB VAPOR BARRIERS OR MEMBRANES. <br />SEE ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. WALLS: <br />�+ <br />#11 BARS AND SMALLER: 1 INCH <br />SECTION BEAMS AND COLUMNS - TIES STIRRUPS SPIRALS <br />1/2" = 1'-0" <br />ALL BAR SIZES: 1-1/2 INCHES <br />SPECIFIED CONCRETE COVER SHALL BE MAINTAINED TO ALL REINFORCEMENT AT CONCRETE <br />REVEALS AND INSETS. SHOP DRAWINGS SHOWING CONCRETE REVEALS AND OTHER INSETS <br />SHALL BE SUBMITTED FOR REVIEW. <br />ANCHORAGE TO HARDENED CONCRETE <br />ANCHORAGE TO HARDENED CONCRETE SHALL INCLUDE MECHANICAL AND ADHESIVE ANCHORS <br />OF SIZE, NUMBER, AND SPACING AS SHOWN ON THE DRAWINGS. HOLES SHALL BE DRILLED AND <br />CLEANED AND ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE <br />MANUFACTURER'S PUBLISHED INSTRUCTIONS AND AN APPROVED ICC-ES (OR IAPMO-UES <br />EQUIVALENT) REPORT. INSPECTION AND TESTING SHALL BE PROVIDED IN ACCORDANCE WITH <br />THE GENERAL NOTES AND THE APPROVED ICC-ES (OR IAPMO-UES EQUIVALENT) REPORT. <br />ACCEPTABLE ANCHORS SHALL HAVE A CURRENT ICC-ES (OR IAPMO-UES EQUIVALENT) REPORT <br />INDICATING THAT THE ANCHOR IS PERMITTED FOR RESISTING SEISMIC LOADS IN CRACKED <br />CONCRETE. UNLESS NOTED OTHERWISE, ANCHORS SHALL BE ASTM A36 THREADED ROD OR <br />ASTM A615, GRADE 60 REINFORCING STEEL DOWELS. <br />HOLES SHALL BE DRILLED WITH ROTARY IMPACT HAMMER OR EQUIVALENT METHOD TO PRODUCE <br />A HOLE WITH A ROUGH INSIDE SURFACE. CORE DRILLING HOLES IS NOT PERMITTED. THE <br />ADHESIVE SHALL BE MIXED, APPLIED, AND CURED IN STRICT ACCORDANCE WITH THE <br />MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS IN THE ICC-ES (OR IAPMO-UES <br />EQUIVALENT) REPORT. ALL PLACEMENT AND CURING SHALL BE CONDUCTED WITH CONCRETE <br />AND AIR TEMPERATURES ABOVE 50 DEGREES FAHRENHEIT. ADHESIVE SHALL BE APPLIED ONLY <br />TO CLEAN, DRY CONCRETE. SPECIFIC EPDXIES MANUFACTURED FOR COLD TEMPERATURES AND <br />WET CONDITIONS MAY BE SUBMITTED FOR APPROVAL ON CASE BY CASE BASIS. POSITIVE <br />PROTECTION SHALL BE PROVIDED SO THAT ANCHORS ARE NOT DISTURBED DURING THE CURING <br />PERIOD. DEFECTIVE OR ABANDONED HOLES SHALL BE FILLED WITH NON -SHRINK GROUT OR AN <br />INJECTABLE ADHESIVE MATCHING THE ADJACENT CONCRETE COMPRESSIVE STRENGTH. <br />GENERAL NOTES <br />Cz <br />2 <br />06 � <br />_,— n <br />Cn <br />Cz <br />Z U' <br />U <br />0 <br />�--_ <br />O � <br />m Q <br />2727 Oakes Ave. <br />Suite 100 <br />Everett, WA 98201 <br />MAGNUSSON g <br />KLEMENCIC " <br />ASSOCIATES <br />�mjc urol + UvA Engineers <br />Seattle Chicago <br />www.mko.com <br />206 292 1200 <br />REVISIONS <br />E <br />0 <br />0 <br />Cc <br />E <br />0 <br />0 <br />4-j <br />CIO <br />n�1 <br />W <br />� <br />U <br />U <br />LU <br />cz <br />JOB. NO. <br />87289.01 <br />DRAWN BY <br />CTM <br />CHECKED BY <br />J PM <br />07/09/2021 <br />STRUCTURAL <br />PLANS AND <br />DETAILS <br />S1.0 <br />