L�1 <br />C <br />V <br />SUB -BASE BEFORE POURING CONCRETE <br />D 1 NOT TO SCALE <br />C1 <br />S301 <br />NOTE 4 <br />NOTE 3 <br />TREATMENT ROOM SUB -BASE PLAN <br />Al SCALE: 3/16 = 1 -0 <br />NOTE 5 <br />NOTE 6 <br />K <br />3 <br />SUB -BASE AFTER POURING CONCRETE <br />D3 NOT TO SCALE <br />MIT <br />FL ..- . <br />-�[oil I <br />DEFINITION OF FF25/FL25: COMES FROM A FLOOR FINISH TOLERANCES SYSTEM ON F-NUMBER CODES WITHIN <br />A. <br />THESE DRAWINGS ARE FOR <br />5 <br />ASTM-El 155, AC1 #117, & CSA #23.1. THESE CODES GIVE TOLERANCE REQUIREMENTS USING ABBREVIATION F <br />REFERENCE ONLY. THEY <br />:, <br />k` 'CONSTRUCTION <br />CIO <br />ARE NOT TO REPLACE <br />DEFINITION OF FF25. "FF" REPRESENTS FLOOR FLATNESS & THE NUMBER REPRESENTS 0.2511[0.6] MAX. <br />DOCUMENTSAND <br />HEIGHT WITHIN A 10'[304.8] PLANE. DETAIL "B" ON THIS SHEET SHOWS AN EXAMPLE OF FF25. <br />SHIELDING STUDIES BY <br />LICENSED PROFESSIONALS. <br />B. <br />DEFINITION OF FL25: 1IFL" REPRESENTS FLOOR LEVELNESS & THE NUMBER REPRESENTS 1 1 •SHALLBE <br />- BY <br />yam' <br />HEIGHT ON A CURVE DISTANCE OF 2411[610] THE HEIGHT SHOULD BE TAKEN FROM THE POINT <br />THE PHYSICIST OF <br />LOCATED AT M I D -CURVE OF A 121f [30.5] DISTANCE. DETAIL "All ON THIS SHEET SHOWS AN EXAMPLE OF FL25. <br />C. <br />UNLESS OTHERWISE NOTED, <br />ALL MATERIALS SUPPLIED <br />HATCH AREA REPRESENTS FLOOR GRADE FLATNESS AND LEVELNESS WHICH MUST HAVE FLATNESS (FF) OF <br />AND INSTALLED ARE THE <br />25 FOR TOTAL AREA & LEVELNESS (FL) OF 25 PER ASTM-E 1155. <br />RESPONSIBILITY OF THE <br />D. <br />REFERSITE PLANNING <br />TO <br />GUIDE (SPG) FOR <br />ADDITIONAL <br />)'. <br />E. <br />ALLSTRUCTURAL <br />CALCULATIONS TO BE <br />COMPLETED BY <br />x r µv <br />STRUCTURAL ENGINEER OF <br />F. <br />ALL FINAL DIMENSIONS TO <br />BE FIELD VERIFIED. <br />REFERENCE FL25: <br />r- "n innrlcn c+nr77r+1r-1r+n-r1t-%K1 C%\/n-rcnA <br />65 FLOOR FINISH TOLERANCES <br />NOT TO SCALE <br />REFERENCE FF25: <br />F-NUMBER SPECIFICATION SYSTEM <br />THAT CODE FLOORING FLATNESS <br />TOLERANCE. <br />1/8" <br />A5 FLOOR FLATNESS <br />NOT TO SCALE <br />EQUIVALENT TO A SINGLE ± 1/4" ALLOWABLE <br />'"17' T^' .ERANCE WHEN MEASURED <br />POINT OF A 24" CURVE DISTANCE. <br />CANNOT BE GREATER THEN 1/4" <br />DISTANCE (12") <br />SHEET NOTES <br />1. <br />THIS FLOOR PLAN IS CUT AT <br />THE SUB -BASE LEVEL, WITHIN <br />THE CONCRETE. <br />2. <br />MOISTURE SENSOR WITH <br />STRAIGHT EDGE ± 1/32" ACCURACY <br />ALARM. A FLOOR DRAIN THAT <br />CAN HANDLE 14 L/min. IS A <br />POSSIBLE ALTERNATIVE. <br />3. <br />SEISMIC BRACKET MAY BE <br />REQUIRED, REFER TO CODE. <br />4. <br />WHERE TRENCHES ARE NOT <br />POSSIBLE, CONDUIT IS AN <br />ACCEPTABLE ALTERNATIVE. <br />5. <br />SUPPLEMENTAL AIR DUCT (SEE <br />0.000 MIDPOINT PLANE <br />M-501) <br />6. <br />COMPRESSED AIR LINE <br />(SEE M-501) <br />EXISTING <br />7. <br />REFER TO Al ON S-501 <br />FLOORING <br />EQUIVALENT TO A SINGLE ± 1/8" <br />ALLOWABLE FLATNESS TOLERANCE <br />WHEN MEASURED BETWEEN ANY <br />TWO PERIPHERAL PTS. 10'-0" WITHIN <br />SHADED AREA. <br />10'-0" 1 /8" <br />EXISTING <br />FLOORING <br />1„i,FA . as] -0 10 - W.Are <br />ISOCENTER <br />6" AREA AROUND <br />EPDXY SET ANCHOR, <br />CLEAR OF ALL REBAR <br />TO DEPTH OF 10". <br />J131 2'-0" x l'-6" x 1'-0" PDU <br />JUNCTION BOX <br />JB2 6" x 6" x 6" PATIENT <br />TABLE JUNCTION BOX <br />JB5 1'-0" x 8" x 8" GANTRY <br />JUNCTION BOX <br />JB6 8" x 8" x 8" COMPRESSED <br />AIR LINE JUNCTION BOX <br />SIGNAL (3" O) - FROM <br />PATIENT TABLE TO <br />QBACK OF GANTRY. <br />(20--0" MAX). <br />POWER (3" 0) - FROM <br />OPATIENT TABLE TO <br />BACK OF GANTRY. <br />(55-0" MAX). <br />OG SIGNAL (1" 0) - INTERCOM <br />TO BACK OF GANTRY (15- <br />MAX) <br />DIMENSION FORMAT: FEET & INCHES <br />ACCURAY INCORPORATED <br />1310 Chesapeake Terrace <br />Sunnyvale, CA 94089 <br />DRAWING INFORMATION <br />A 1 5.18.2020 <br />PROVIDENCE REGIONAL MEDICAL <br />CENTER EVERETT <br />TOMOTHERAPY RADIXACT <br />EVERETT, WA <br />REGIONAL PROJECT MANAGER <br />LINDA MAYNARD <br />SITE PLANNING COORDINATOR <br />JASON LENTZ <br />PAGE NUMBER <br />5of20 <br />SHEET NUMBER <br />S-101 <br />STRUCTURAL <br />FLOOR PLAN <br />