1717 13TH ST 2021 Plans 2022-12-01
>
Address Records
>
13TH ST
>
1717
>
Plans
>
1717 13TH ST 2021 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:20:47 AM
Creation date
6/21/2022 3:26:33 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1717
Permit
B2107-050
Year
2021
Notes
REPLACE TOMOGRAPHY UNIT AND LINEAR ACCELERATOR UNIT WITH NEW
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL LEGEND <br />SYMBOL DESCRIPTION <br />DETAIL SYMBOL- A <br />o IDENTIFYING NUMBER <br />B <br />= SHEET WHERE DETAIL IS SHOWN <br />DETAIL SYMBOL: A <br />® IDENTIFYING NUMBER <br />B <br />m SHEET WHERE DETAIL IS TAKEN <br />C <br />o SHEET WHERE DETAIL IS SHOWN <br />SECTION SYMBOL: A <br />= IDENTIFYING LETTER <br />B <br />® SHEET WHERE SECTION IS SHOWN <br />SECTION SYMBOL: A = IDENTIFYING LETTER <br />B ® SHEET WHERE SECTION IS TAKEN <br />C ® SHEET WHERE SECTION IS SHOWN <br />ABBREVIATIONS <br />I R DESCRIPTION AB6R DESCRIPTION <br />ALIT/ <br />ABOVE <br />L <br />LENGTH <br />AD <br />ACCESS DOOR <br />LAT <br />LEAVING AIR TEMPERATURE <br />AHU <br />AIR HANDLING UNIT <br />LBS <br />POUNDS <br />AL <br />ACOUSTIC LINED <br />LF <br />LINEAR FOOT/FEET <br />AP <br />ACCESS PANEL <br />LVG <br />LEAVING <br />APD <br />AIR PRESSURE DROP <br />L G <br />LOW WALL GRILLE <br />ARCH <br />ARCHITECT/ARCHITECTURAL <br />LWR <br />LOW WALL REGISTER <br />ARV <br />AUTOMATIC RELIEF VALVE or <br />LWT <br />LEAVING WATER TEMPERATURE <br />ACID RESTISTANT VENT <br />ARW <br />ACID RESTISTANT WASTE <br />MAX <br />MAXIMUM <br />MBH <br />1000 BRITISH THERMAL <br />BDD <br />BACKDRAFT DAMPER <br />UNITS PER HOUR <br />BFP <br />BACKFLOW PR LATER <br />MCC <br />MOTOR CONTROL CENTER <br />BHP <br />BRAKE HORSEPOWER <br />MECH <br />MECHANICAL <br />BG <br />BELOW GROUND <br />MFR <br />MANUFACTURER <br />UJ <br />BETWEEN JOISTS <br />MIN <br />MINIMUM <br />BTU <br />BRITISH THERMAL UNIT <br />MISC <br />MISCELLANEOUS <br />BTUH <br />BRITISH THERMAL UNITS PER HOUR <br />MOUNTED <br />MTG <br />MOUNTING <br />C <br />CENTIGRADE <br />CC <br />COOLING COIL <br />N/A <br />NOT APPLICABLE <br />CD <br />CEILING DIFFUSER <br />N/C <br />NORMALLY CLOSED <br />CFM <br />CUBIC FEET PER MINUTE <br />N/O <br />NORMALLY OPEN <br />CG <br />CEILING GRILLE <br />NC <br />NOISE CRITERIA <br />CI <br />CAST IRON <br />NIC <br />NOT IN CONTRACT <br />CLG <br />CEILING <br />NTS <br />NOT TO SCALE <br />C0 <br />CLEANOUT <br />CCNC <br />CONCRETE <br />OA <br />OUTSIDE AIR <br />CONN <br />CONNECT or CONNECTION <br />OBD <br />OPPOSED BLADE DAMPER <br />CONST <br />CONSTRUCTION <br />O/C <br />ON CENTER <br />CONT <br />CONTINUATION <br />OD <br />OUTSIDE DIAMETER <br />CR <br />CONDENSATE RETURN <br />OPNG <br />OPENING <br />DB <br />DECIBLE or DRY BULB <br />PCV <br />PRESSURE CONTROL VALVE <br />DDC <br />DIRECT DIGITAL CONTROL <br />PD <br />PRESSURE DROP <br />DIA <br />DIAMETER <br />PH or 0 <br />PHASE <br />DIM <br />DIMENSION <br />PLCS <br />PLACES <br />DN <br />DOWN <br />POC <br />POINT OF CONNECTION <br />DPR <br />DAMPER <br />POUA <br />POINT OF USE ALARM <br />DWG <br />DRAWING <br />PRV <br />PRESSURE REDUCING VALVE <br />PSI <br />POUNDS PER SQUARE INCH <br />E-100 <br />EXHAUST AIR <br />PSIG <br />POUNDS PER SQUARE INCH GAGE <br />NUMBER INDICATES CFM QUANTITY <br />EA <br />EACH <br />R-100 <br />RETURN AIR <br />EAT <br />ENTERING AIR TEMPERATURE <br />NUMBER INDICATES CFM QUANTITY <br />EF <br />EXHAUST FAN <br />RA <br />RETURN AIR <br />EG <br />EXHAUST GRILLE <br />RAG <br />RETURN AIR GRILLE <br />ELEC <br />ELECTRIC or ELECTRICAL <br />REQD <br />REQUIRED <br />ELEV <br />ELEVATION <br />RPBP <br />REDUCED PRESSURE BACKFLOW <br />EMCS <br />ENERGY MANAGEMENT CONTROL SYSTEM <br />PREVENTOR <br />ESP <br />EXTERNAL STATIC PRESSURE <br />EWT <br />ENTERING WATER TEMPERATURE <br />RPM <br />REVOLUTIONS PER MINUTE <br />EXH <br />EXHAUST <br />EXST or (E) <br />EXISTING <br />S-100 <br />SUPPLY AIR <br />NUMBER INDICATES CFM QUANTITY <br />F <br />FAHRENHEIT <br />SA <br />SUPPLY AIR <br />FA <br />FACE AREA <br />SF <br />SUPPLY FAN <br />FCO <br />FLOOR CLFANOUT <br />SLIT <br />SHEET <br />FCU <br />FAN COIL UNIT <br />Sim <br />SIMILAR <br />FD <br />FLOOR DRAIN <br />SP <br />STATIC PRESSURE <br />FDPR <br />FIRE DAMPER <br />SID <br />SQUARE <br />F-FD <br />FUNNEL FLOOR DRAIN <br />SQ FT <br />SQUARE FOOT/FEET <br />FF <br />FINAL FILTER <br />SS <br />STAINLESS STEEL <br />FLR <br />FLOOR <br />STD <br />STANDARD <br />FPM <br />FEET PER MINUTE <br />FPS <br />FEET PER SECOND <br />THK <br />THICK <br />FT <br />FOOT/FEET <br />TP <br />TRAP PRIMER or TEST PLUG <br />FV <br />FACE VELOCITY <br />TYP <br />TYPICAL <br />TU <br />TERMINAL UNIT <br />GA <br />GAGE or GAUGE <br />GAL <br />GALLON <br />UBC <br />UNIFORM BUILDING CODE <br />GALV <br />GALVANIZED <br />UFC <br />UNIFORM FIRE CODE <br />GPH <br />GALLONS PER HOUR <br />UMC <br />UNIFORM MECHANICAL CODE <br />GPM <br />GALLONS PER MINUTE <br />UPC <br />UNIFORM PLUMBING CODE <br />UG <br />UNDERGROUND <br />H <br />HEIGHT <br />UH <br />UNIT HEATER <br />HD <br />HEAD <br />HP <br />HORSEPOWER <br />VA <br />VALVE <br />HTG <br />HEATING <br />VAC <br />VACUUM <br />HVAC <br />HEATING, VENTILATION AND <br />VAV <br />VARIABLE AIR VOLUME <br />AIR CONDITIONING <br />VD <br />VOLUME DAMPER <br />HWG <br />HIGH WALL GRILLE <br />VEL <br />VELOCITY <br />HWR <br />HIGH WALL REGISTER <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />HZ <br />HERTZ <br />VTR <br />VENT THRU ROOF <br />WIDE <br />ID <br />INSIDE DIAMETER <br />W/ <br />W/0 <br />WITH <br />WITHOUT <br />IE <br />INVERT ELEVATION <br />WB <br />WET BULB <br />IN <br />INCH or INCHES <br />WCO <br />WALL CLEANOUT <br />INSUL <br />INSULATION <br />WG <br />WATER GAGE <br />INV <br />INVERT <br />WGE <br />WASTE GAS EVACUATION <br />KW <br />KILOWATT <br />WPD <br />WATER PRESSURE DROP <br />KWH <br />KILOWATT HOUR <br />WT <br />WEIGHT <br />AIR DISTRIBUTION LEGEND <br />DESCRIPTION <br />11102 <br />18x12 <br />R R <br />_D <br />D <br />18x12"O <br />113x12"0 <br />1�xi2 <br />1�xi0 <br />18x10 <br />18x12 <br />,. <br />I x <br />1 <br />Is <br />FLEX <br />®' AD <br />6 ®� <br />TATES <br />EXISTING DUCT OR EQUIPMENT <br />rNDICATES DUCT OR EQUIPMENT <br />TO BE REMOVED <br />RECTANGULARSUPPLYDUCT ELBOW <br />TURNED DOWN OR AWAY <br />RECTANGULAR RETURN/EXHAUST_ <br />END OF DUCT WITH CAP <br />(UNLESS INDICATED OTHERWISE) <br />FLEXIBLE DUCT <br />[1`I1Tl�rL�I�I�'�'31sZ�Z�Tk7 <br />RECTANGULAR ELBOW <br />(SINGLE LINE) I <br />PIPING LEGEND <br />_ <br />SYMBOL ABBR DESCRIPTIONSYMBOL fR DESCRIPTION <br />LIGHT LIEWORK INDICATES <br />CAP <br />PIPE END CAP <br />EXISTING PIPING OR EQUIPMENT <br />PIPE TURNING DOWN OR AWAY <br />INDICATES PIPING OR EQUIPMENT <br />TO BE REMOVED <br />PIPE TURNING UP OR TOWARD <br />SS <br />SANITARY SEWER o OUTSIDE BUILDING AND <br />PIPE TURNING DOWN OR AWAY (TEE) <br />BELOW GROUND <br />REDUCER (NOT TYPICALLY SHOWN) <br />SD <br />SO <br />STORM DRAIN o OUTSIDE BUILDING AND <br />BELOW GROUND <br />PIPE CONNECTION <br />W <br />WASTE (& SOIL) e ABOVE GROUND o INTERIOR <br />W <br />WASTE (& SOIL) ® BELOW GROUND e INTERIOR <br />PIPE ANCHOR <br />(NOT ALWAYS SHOWN, SEE SPECIFICATIONS) <br />®®®®-®®®®®®® <br />V <br />VENT <br />ARW <br />ACID RESISTANT WASTE <br />PIPE ALIGNMENT GUIDE <br />(NOT ALWAYS SHOWN, SEE SPECIFICATIONS) <br />®®®® ®®®®® <br />ACfD RESIST T VENT <br />CW <br />COLD WATER m DOMESTIC <br />S <br />HIS <br />HOSE BIBB <br />® <br />®® <br />HW <br />HOT WATER DOMESTIC <br />WH/NFWH <br />WALL HYDRANT or NON -FREEZE WALL HYDRANT <br />® - - <br />HWC <br />HOT WATER CIRCULATING o DOMESTIC <br />�II <br />CO/WCO <br />CLEANOUT ®r WALL CLEANOUT <br />RD <br />RD <br />RAINWATER DRAINAGE o ABOVE GROUND <br />FCO/SCO <br />FLUSH CLEANOUT or SURFACE CLEANOUT <br />—RD— — <br />RD <br />RAINWATER DRAINAGE - BELOW GROUND <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />ORD <br />ORD <br />RAINWATER DRAINAGE OVERFLOW ® ABOVE CROUND <br />FIRE SPRINKLER ALARM GONG <br />® —ORD— ® <br />ORD <br />RAINWATER DRAINAGE OVERFLOW - BELOW GROUND <br />D <br />D <br />DRAIN ® INDIRECT <br />AD <br />AREA DRAIN <br />RV <br />RELIEF VALVE VENT <br />FD or FEB <br />FLOOR DRAIN ®r FUNNEL FLOOR DRAIN <br />PIPE SLOPE DIRECTION <br />FS <br />FLOOR SINK <br />ICW <br />ICW <br />INDUSTRIAL COLD WATER <br />® <br />OD <br />OVERFLOW DRAIN <br />S <br />SCW <br />SOFT COLD WATER <br />0 <br />RD <br />ROOF DRAIN <br />_FCW <br />FCW <br />COLD WATER (FLUSHING SYSTEM) <br />DOI <br />SHUTOFF VALVE (AS SPECIFIED FOR PIPING SYSTEM) <br />®IHW ®® <br />IHW <br />INDUSTRIAL HOT WATER <br />L VALVE <br />® ® ® <br />KHW <br />KITCHEN HOT WATER <br />CKV <br />CHECK VALVE <br />—KHWC ® ®- <br />KHWC <br />KITCHEN HOT WATER CIRCULATING <br />II <br />BFV <br />BUTTERFLY VALVE <br />MS <br />LHW ® ® <br />LHW <br />LAUNDRY HOT WATER <br />II <br />BFV <br />BUTTERFLY VALVE / MEMORY STOP <br />®LHWC ®®® <br />LHWC <br />LAUNDRY HOT WATER CIRCULATING <br />BAL VA <br />BALANCING VALVE <br />NPW <br />NPW <br />NON -POTABLE WATER <br />BSV <br />COMBINATION BALANCING/SHUTOFF VALVE <br />IW <br />IW <br />IRRIGATION WATER <br />ACV <br />2-WAY MODULATING CONTROL VALVE W/ ACTUATOR <br />DI <br />DI <br />DEIONIZED WATER <br />ACV <br />3-WAY MODULATING CONTROL VALVE W/ ACTUATOR <br />DW <br />DW <br />DISTILLED WATER <br />CS <br />CS <br />CONDENSER WATER SUPPLY <br />2-POSITION CONTROL VALVE <br />® ® ®CR® ® ® <br />CR <br />CONDENSER WATER RETURN <br />PRV <br />PRESSURE REDUCING VALVE <br />S <br />CWS <br />CHILLED WATER SUPPLY o COOLING <br />RV <br />RELIEF VALVE <br />® ® ®CWR® ® — <br />CWR <br />CHILLED WATER RETURN e COOLING <br />S <br />FLOW MEASUREMENT STATION <br />RL <br />RL <br />LIQUID LINE o REFRIGERANT <br />STR <br />Y-TYPE STRAINER <br />RS <br />RS <br />SUCTION LINE e REFRIGERANT <br />w <br />GLV <br />GLOBE VALVE <br />HG <br />HG <br />HOT GAS LINE o REFRIGERANT <br />OSY VA <br />OUTSIDE SCREW AND YOKE VALVE <br />HWS <br />HWS <br />HOT WATER HEATING SUPPLY <br />EXP VA <br />EXPANSION VALVE <br />® ® ® HWR ® ® ® <br />HWR <br />HOT WATER HEATING RETURN <br />FOS <br />FOS <br />FUEL OIL SUPPLY <br />FCV <br />FLOW CONTROL VALVE <br />— ®FOR® ® ® <br />FOR <br />FUEL OIL RETURN <br />III <br />UNION <br />G <br />G <br />NATURAL GAS <br />FLANGES <br />LPG <br />LPG <br />LIQUID PETROLEUM GAS <br />THREADED DRAIN PLUG <br />LPS <br />LIDS <br />LOW PRESSURE STEAM SUPPLY <br />MALE (GARDEN) HOSE CONNECTION WITH CAP <br />®®® LPR ® ® — <br />LPR <br />LOW PRESSURE STEAM CONDENSATE RETURN <br />MPS <br />MPS(20) <br />MEDIUM PRESSURES SUPPLY <br />TIP <br />PEST PLUG <br />NUMBER IN PARENTHESIS INDICATES PSI <br />SHOCK ARRESTOR <br />® ® ®MPR ® ® ® <br />MP(20) <br />MEDIUM PRESSURE STEAMCONDENSATE RETURN <br />NUMBER IN PARENTHESIS INDICATES PSI <br />HPS <br />HPS(100) <br />HIGH PRESSURE STEAM SUPPLY <br />T <br />TH or IT <br />THERMOMETER (TEMPERATURE INDICATOR) <br />NUMBER IN PARENTHESIS INDICATES PSI <br />®®® HPR ® <br />HP (100) <br />HIGH PRESSURE STEAM CONDENSATE RETURN <br />B STR <br />BASKET STRAINER <br />NUMBER IN PARETHESIS INDICATES PSI <br />®® ®PR®®® <br />PR <br />STEAM CONDENSATE RETURN (PUMPED) <br />P <br />PI <br />PRESSURE INDICATOR <br />ATV <br />ATV <br />ATMOSPHERIC VENT <br />V <br />AUTOMATIC AIR VENT <br />MA <br />COMPRESSED MEDICAL AIR <br />LA <br />LA <br />COMPRESSED LABORATORY AIR <br />MANUAL AIR VENT <br />MV <br />MEDICAL VACUUM <br />02 <br />02 <br />OXYGEN <br />PUMP (DIAL ) <br />N20 <br />N20 <br />NITROUS OXIDE <br />N2 <br />N2 <br />NITROGEN <br />FLEXIBLE CONNECTOR <br />CO2 <br />CO2 <br />CARBON DIOXIDE <br />A <br />A <br />COMPRESSED AIR <br />INDICATES ASSEMBLY OF PIPING COMPONENTS <br />(AS NOTED OR DIAGRAMED) <br />V <br />V <br />VACUUM <br />LV <br />LV <br />LABORATORY VACUUM <br />WGE <br />WGE <br />WASTE GAS EVACUATION <br />DUCT FITTING REQUIREMENTS <br />THE FOLLOWING DUCT FITTINGS ARE CONSIDERED ACCEPTABLE. THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR OTHER FITTINGS PRIOR TO FABRICATION. ONLY FITTINGS WITH EQUAL OR <br />W/ ACTUATOR LOWER PRESSURE DROP WILL BE CONSIDERED. <br />BDD 13ACKDRAFT DAMPER ris Ir'T V! POUM nr7c'QrTc 110AMOM Ill IPT TAM)CM <br />ar 11Vs 'alone rill -Is v'® p <br />&L 1Jm9J urwixtAm UY WUORE <br />FIRST NUMBER INDICATES COIL H TING CAPACITY (KILO®WATTS), TE MI UNITSSECOND NUMBER INDICATES SUPPLY VOLTAGE (IN VOLTS), <br />THIRD NUMBER INDICATES P E(S). ®46 OR 9 L i IUS ELBOWS 2W, OUT NOT <br />THAN 12" ACCESS PANEL <br />HYDRONIC HEATING OR COOLING COIL.. REFER TO D WING 12"x12" ACCESS P UNDEtl R <br />3 <br />R <br />EL ,r%w IF <br />NOTES O BOTTOM OF DUCT <br />AND/OR SCHEDULE FOR CAPACITY. UNDE000 FPM) <br />� UPSTREAM OF TURNING rr OBTAIN PRIOR APPROVAL FOR ALL 1 <br />VANES. REQUIRED FOR RETURN & EXHAUST LOCATIONS <br />RETURN AND EXHAUST DUCTS mll"TtIRNINr. <br />~-AIR EXT CTO47�ADJUSTABLE FROM <br />AIR FILTER TURNING VANES VANF-q OUTSIDE DUCTWORK. <br />� 11. I Tel <br />INDICATES SUPPLY 3 FLOW DIRECTION <br />i" &'` _ 5 9'.f. !" <br />I UNDER <br />_;: <br />,�. <br />MECHANICAL SHEET INDE11 <br />SHEET NUMBER <br />DESCRIPTION <br />MO.1 <br />COVER SHEET & GENERAL INFORMATION <br />MO.2 <br />MECHANICAL GENERAL NOTES <br />MO.3 <br />MECHANICAL SCHEDULES <br />MO.4 <br />MECHANICAL AND PLUMBING SPECIFICATIONS <br />M2.0 <br />DEMO AND NEW BASEMENT PLAN - HVAC <br />M2.1 <br />DEMO AND NEW FLOOR PLAN o HVAC <br />M2.2 <br />DEMO AND NEW FLOOR PLAN ® HVAC PIPING <br />M4.1 <br />DETAILS <br />GENERAL MECHANICAL NOTES <br />cn <br />cn <br />�_4==�; <br />C3 <br />700 <br />2727 Oakes Ave. <br />Suite 100 <br />Everett, WA 98201 <br />719121 <br />0 <br />< <br />V <br />71C <br />> <br />JOB. NO. <br />211040 <br />DRAWN BY <br />CEI <br />CHECKED BY <br />H B <br />PERMIT ISSUE <br />7-09-21 <br />