My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 19TH AVE SE 2019 Plans 2022-12-07 (2)
>
Address Records
>
19TH AVE SE
>
10200
>
Plans
>
10200 19TH AVE SE 2019 Plans 2022-12-07 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2022 8:56:50 AM
Creation date
6/21/2022 4:00:13 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10200
Permit
B1901-007
Year
2019
Notes
RENOVATE FRESH MEAT & DELI, ADD EXT REFRIGERATION RM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GAS VALVE FOR FS#1 <br />O-� <br />**GAS VALVE PROVIDED BY PLUMBER" <br />CONFIRM SIZE AND CALL 425-212-5996 TO ORDER. TYPICAL LEAD TIME 3-5 WORKING DAYS DELIVERED. <br />GAS VALVES AND STRAINERS <br />GAS VALVE SIZING <br />GAS VALVE DIMENSIONS <br />INSTALLATION <br />PART NUMBERS <br />TYPE <br />SIZE <br />VOLTAGE <br />MIN. <br />MAX. <br />FLOW AT I <br />DIM "N' <br />DIM "B" <br />DIM "C" <br />DIM "D" <br />DIM "F" <br />DIM "G" <br />MOUNTING <br />GAS VALVE PART <br />STRAINER PART <br />GAS <br />INLET <br />INLET <br />IN.W.C. DROP <br />ORIENTATION <br />NUMBER <br />NUMBER <br />VALVE/STRAINER <br />PRESSURE <br />PRESSURE <br />NATURAL GAS <br />KIT <br />ELECTRICAL <br />2" <br />120 <br />0 PSI <br />5 PSI <br />2,940,500 <br />7-518" <br />6-3/8" <br />7-1/4" <br />7-13-16" <br />15-5/8" <br />13-15116" <br />HORIZONTAL/ <br />8214280 <br />4417K68 <br />(SC)EGVA2 <br />VAC <br />(0 IN W.C.) <br />(138 IN.W.C.) <br />BTU/FIR <br />VERTICAL <br />ELECTRIC GAS VALVES ONLY <br />120 VAC GAS VALVES CAN BE MOUNTED WITH THE SOLENOID <br />IN ANY POSITION ABOVE HORIZONTAL <br />24 VDC GAS VALVES MUST BE MOUNTED WITH SOLENOID <br />VERTICAL AND UPRIGHT <br />IMWLIJZW��# <br />DIM "A" <br />DIM "G" <br />DIM "F'y <br />LECTRIC GAS VALVE <br />-FLOW <br />DIM "C" <br />`ti4"WIN <br />\X" <br />DIM "D" <br />STRAINER <br />SC —ELECTRIC GAS VALVE <br />Hood Front <br />Hood Front <br />E <br />Er <br />E <br />:2 <br />(D <br />0181, <br />018" <br />OLD <br />Hood # 1 (Deli Left Side) J 5 45881 12" <br />Hood # 2 (Deli Right Side) Job # 3645881 12" <br />Model: ND-2 Size: 78"x3O" Len <br />e" 1 13'2" EEI <br />A? <br />K) Model: ND-2 Size: 78"x30" Length: 13'2" <br />Hood <br />Back <br />Hood <br />Back <br />PIPE HOODS SO TANK CAN BE LOCATED AT EITHER SIDE <br />06300' <br />IN @ 1N)" �1N <br />ROTISSERIE HOOD FIRE SUPPRESSION SYSTEM DETAL <br />NOT TO SCALE <br />Controls shall be listed by ETL (UL 508A) and shall comply with demand ventilation system <br />turndown requirements outlined in IECC 40328 (2015). <br />The control enclosure shall be NEMA 1 rated and listed for installation inside of the <br />exhaust hood utility cabinet. The control enclosure may be constructed of stainless steel <br />or painted steel. <br />Temperature probe(s) located in the exhaust duct riser(s) shall be constructed of <br />stainless steel. <br />A digital controller shall be provided to activate the hood exhaust fans dynamically based <br />on a fixed differential between the ambient and duct temperatures sensors. This function <br />shall meet the requirements of IMC 5.7.1.1. <br />A digital controller shall provide adjustable hysteresis settings to prevent cycling of the <br />fans after the cooking appliances have been turned off and/or the heat in the exhaust <br />system is reduced. <br />A digital controller shall provide an adjustable minimum fan run-time setting to prevent fan <br />cycling. <br />- A digital controller shall allow for external BMS fan control via Dry Contact (external <br />control shall not override fan operation logic as required by code). <br />- An LCD interface shall be provided with the following features: <br />a. On/Off push button fan & light switch activation <br />b. Integrated gas valve reset for electronic gas valves (no reset relay required) <br />c. VFD Fault display with audible & visual alarm notification <br />d. Duct temperature sensor failure detection with audible & visual alarm notification <br />e. Mis-wired duct temperature sensor detection with audible & visual alarm notification <br />f. A single low voltage Cat-5 RJ45 wiring connection <br />g. An energy savings indicator that utilizes measured kWh from the VFDs <br />8.63" <br />J_ <br />0.875" <br />KNOCK -OUT <br />9X <br />CONTROL CABINET -TOP VIEW <br />EMS CONTROL CABINET DETAILS <br />NOT TO SCALE <br />18.00" <br />EMS PANEL <br />COOLING FAN <br />**DO NOT BLOCK** <br />1.65" - <br />2.00" <br />2.00" TYP <br />2.04" <br />---- 0.875" KNOCKOUT 8X <br />3 1/2" <br />CONTROL CABINET -SIDE VIEW <br />0.75" TYP <br />7 <br />1.25" TYP <br />L <br />� <br />— — — — — — ----- — — — — — -- — — — — <br />.069" 2X <br />SC -EMS MOUNTING DETAIL <br />1 <br />0.31 <br />2X <br />0. 31 2X <br />0. 50" 2X <br />1.25" TYP <br />0.75"TYP <br />EXPIRES, 2/18/20 <br />O 2018 1 ALL RIGHTS RESERVED <br />12A4.2018 <br />DRAWN BY I SCHRIVER <br />CHECKED BY I NITSCHKE <br />REVISIONS <br />KITCHEN HOOD DETAILS <br />M103 <br />06.29.17 11:08 PM I UCOSTC0\0114 Everett, WAB1MCADNMech\M103.dwg <br />
The URL can be used to link to this page
Your browser does not support the video tag.