Laserfiche WebLink
01 <br />GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL ISSUE A CHANGE ORDER PROPOSAL ON FORM ACCEPTABLE TO <br />OWNER TO THE ARCHITECT AND OWNER FOR SIGNATURE. FIELD DIRECTIVES AND/OR CHANGES SHALL NOT BE INCLUDED IN THE <br />WORK UNTIL THE ARCHITECT AND OWNER HAVE SIGNED THE CHANGE ORDER. NO WORK IS TO BE DONE AT THE REQUEST OF <br />THE WAREHOUSE MANAGER. <br />B. THE GENERAL CONTRACTOR IS THE PROJECT COORDINATOR, AND SHALL PROVIDE COORDINATION AND CONTROL FOR ALL WORK <br />OF THE ENTIRE CONTRACT INCLUDED IN THESE CONTRACT DOCUMENTS AND SPECIFIED HEREIN. <br />014000 - QUALITY REQUIREMENTS <br />A. COSTS FOR INSPECTIONS AND TESTS REQUIRED BY BUILDING OFFICIALS AND REQUESTED BY OWNER ON EARTHWORK, STEEL <br />WORK, AND CONCRETE PLACED ON THE SITE WILL BE PAID BY THE OWNER. <br />B. COSTS FOR RE -INSPECTIONS AND RE -TESTS, AND ADDED COSTS FOR INSPECTIONS AND TESTS DUE TO POOR WORKMANSHIP, <br />NON-COMPLIANCE WITH THE CONTRACT DOCUMENTS, LATE SCHEDULING, CANCELLATIONS, OR ILL-TIMED NOTICES ARE THE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />1. WHEN INITIAL TESTS DISPLAY NON-COMPLIANCE WITH THE CONTRACT DOCUMENTS, THE SAME TESTING AGENCY THAT <br />PERFORMED THE INITIAL TESTS SHALL DO THE WORK OF RE -INSPECTION OR RE -TESTING THE EARLIER TESTS. <br />2. PAYMENT FOR RE -INSPECTION OR RE -TEST COSTS WILL BE MADE TO THE TESTING AGENCY BY THE OWNER, BUT THE CONTRACT <br />SUM IN THE AGREEMENT BETWEEN OWNER AND CONTRACTOR WILL BE ADJUSTED BY CHANGE ORDER TO RECOVER THE COST. <br />C. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF MATERIALS AND EQUIPMENT. <br />015000 - TEMPORARY FACILITIES <br />A. TEMPORARY UTILITIES: USE OF OWNER'S EXISTING ELECTRICAL, SEWAGE, AND WATER WILL BE PERMITTED WITHOUT METERING. <br />CONTRACTOR SHALL PROVIDE SAFE TEMPORARY CONNECTIONS AND MAINTAIN CONDITIONS ACCEPTABLE TO THE OWNER. <br />B. SANITARY FACILITIES: USE OF OWNER'S EXISTING TOILET FACILITIES WILL BE PERMITTED, AS LONG AS FACILITIES ARE CLEANED <br />AND MAINTAINED IN A CONDITION ACCEPTABLE TO OWNER. AT SUBSTANTIAL COMPLETION, RESTORE THESE FACILITIES TO <br />CONDITION EXISTING BEFORE INITIAL USE. <br />C. TEMPORARY PARTITIONS: PROVIDE DUSTPROOF PARTITIONS TO LIMIT DUST AND DIRT MIGRATION AND TO SEPARATE AREAS <br />OCCUPIED BY OWNER FROM FUMES AND NOISE. <br />1. INSULATE PARTITIONS TO CONTROL NOISE TRANSMISSION TO OCCUPIED AREAS. <br />2. SEAL JOINTS AND PERIMETER. EQUIP PARTITIONS WITH GASKETED DUSTPROOF DOORS AND SECURITY LOCKS WHERE <br />OPENINGS ARE REQUIRED. <br />3. PROTECT AIR -HANDLING EQUIPMENT. <br />4. PROVIDE WALK -OFF MATS AT EACH ENTRANCE THROUGH TEMPORARY PARTITION. <br />5. PLASTIC SHEETING USED SHALL BE FLAME RESISTANT. <br />D. BARRICADES, WARNING SIGNS, AND LIGHTS: <br />1. PROVIDE FENCES AND SAFEGUARDS NECESSARY FOR THE CONVENIENCE AND PROTECTION OF THE PUBLIC, AS REQUIRED BY <br />CODE AND LAW ENFORCEMENT REGULATIONS. <br />017329 - CUTTING AND PATCHING <br />A. CUTTING: CUT EXISTING CONSTRUCTION BY SAWING, DRILLING, BREAKING, CHIPPING, GRINDING, AND SIMILAR OPERATIONS, <br />INCLUDING EXCAVATION, USING METHODS LEAST !LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJOINING CONSTRUCTION. <br />1. IN GENERAL, USE HAND OR SMALL POWER TOOLS DESIGNED FOR SAWING AND GRINDING, NOT HAMMERING AND CHOPPING. <br />CUT HOLES AND SLOTS AS SMALL AS POSSIBLE, NEATLY TO SIZE REQUIRED, AND WITH MINIMUM DISTURBANCE OF ADJACENT <br />SURFACES. TEMPORARILY COVER OPENINGS WHEN NOT IN USE. <br />2. EXISTING FINISHED SURFACES: CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED SURFACES. <br />3. CONCRETE, MASONRY: CUT USING A CUTTING MACHINE, SUCH AS AN ABRASIVE SAW OR A DIAMOND CORE DRILL. <br />4. MECHANICAL AND ELECTRICAL SERVICES: CUT OFF PIPE OR CONDUIT IN WALLS OR PARTITIONS TO BE REMOVED. CAP, VALVE, <br />OR PLUG AND SEAL REMAINING PORTION OF PIPE OR CONDUIT TO PREVENT ENTRANCE OF MOISTURE OR OTHER FOREIGN <br />MATTER AFTER CUTTING. <br />B. PATCHING: PATCH CONSTRUCTION BY FILLING, REPAIRING, REFINISHING, CLOSING UP, AND SIMILAR OPERATIONS FOLLOWING <br />PERFORMANCE OF OTHER WORK. PATCH WITH DURABLE SEAMS THAT ARE AS INVISIBLE AS POSSIBLE. PROVIDE MATERIALS AND <br />COMPLY WITH INSTALLATION REQUIREMENTS SPECIFIED IN OTHER SECTIONS OF THESE SPECIFICATIONS. <br />1. EXPOSED FINISHES: RESTORE EXPOSED FINISHES OF PATCHED AREAS AND EXTEND FINISH RESTORATION INTO RETAINED <br />ADJOINING CONSTRUCTION IN A MANNER THAT WILL ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. <br />2. FLOORS AND WALLS: WHERE WALLS OR PARTITIONS THAT ARE REMOVED EXTEND ONE FINISHED AREA INTO ANOTHER, PATCH <br />AND REPAIR FLOOR AND WALL SURFACES IN THE NEW SPACE. PROVIDE AN EVEN SURFACE OF UNIFORM FINISH, COLOR, <br />TEXTURE, AND APPEARANCE. REMOVE EXISTING FLOOR AND WALL COVERINGS AND REPLACE WITH NEW MATERIALS, IF <br />NECESSARY, TO ACHIEVE UNIFORM COLOR AND APPEARANCE. <br />3. WHERE PATCHING OCCURS IN A PAINTED SURFACE, APPLY PRIMER AND INTERMEDIATE PAINT COATS OVER THE PATCH AND <br />APPLY FINAL PAINT COAT OVER ENTIRE UNBROKEN SURFACE CONTAINING THE PATCH. PROVIDE ADDITIONAL COATS UNTIL <br />PATCH BLENDS WITH ADJACENT SURFACES. <br />4. CEILINGS: PATCH, REPAIR, OR RE -HANG EXISTING CEILINGS AS NECESSARY TO PROVIDE AN EVEN PLANE SURFACE OF UNIFORM <br />APPEARANCE. <br />33300 - CONCRETE FLOOR AND CURBS <br />A. PROPORTIONING AND DESIGN OF CONCRETE MIXES: <br />1. PREPARE DESIGN MIX FOR 3500 PSI STRENGTH CONCRETE BY EITHER LABORATORY TRIAL BATCH OR FIELD EXPERIENCE <br />METHODS AS SPECIFIED IN ACI 301. IF TRIAL BATCH METHOD USED, USE AN INDEPENDENT TESTING FACILITY FOR PREPARING <br />AND REPORTING PROPOSED MIX DESIGNS. THE TESTING FACILITY SHALL NOT BE THE SAME AS USED FOR FIELD QUALITY <br />CONTROL TESTING. <br />2. USE NO FLY ASH IN CONCRETE. <br />3. USE NO AIR ENTRAINMENT. <br />B. CONCRETE SLAB REPAIR PRODUCT: TWO-PART HYBRID URETHANE THAT COMBINES WITH SAND TO FORM ATOUGH INSTANT <br />POLYMER CONCRETE. <br />1. ACCEPTABLE PRODUCT: "10-MINUTE CONCRETE MENDER" (VOC 5.5 G/L) MANUFACTURED BY ROADWARE INC., 2100 <br />WENTWORTH AVE., SOUTH SAINT PAUL, MN S5075; PHONE: (800) 5227623 OR (651) 457-6122; FAX: (651) 457-1420; <br />WWW.CONCRETEMENDER.COM. <br />051200- STRUCTURAL STEEL FRAMING <br />A. STEEL MATERIALS: STRUCTURAL QUALITY, OF SIZES AND TYPES NOTED ON STRUCTURAL DRAWINGS. <br />1. CARBON STEEL SHAPES, PLATES AND BARS ASTM A 36/A 36M. <br />2. STEEL TUBE SECTIONS: ASTM A 500/A 500M, GRADE B. <br />B. WELDED, RIVETED OR BOLTED CONNECTIONS IN ACCORDANCE WITH AISC CODE. <br />1. WELDING IN ACCORDANCE WITH CURRENT "CODE FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION" OF AMERICAN <br />WELDING SOCIETY. <br />2. HOLES PUNCHED OR DRILLED; CUTTING TORCH NOT PERMITTED. <br />054000 - COLD FORMED METAL FRAMING <br />A. WALL FRAMING: MANUFACTURER'S STANDARD STEEL STUDS, OF WEB DEPTHS INDICATED, WITH STIFFENED FLANGES, <br />COMPLYING WITH ASTM C 955, AND AS FOLLOWS: <br />1. MINIMUM UNCOATED -STEEL THICKNESS: 18 GAUGE 0.0428 INCH. <br />2. FLANGE WIDTH: 1-5/8 INCHES (41 MM). <br />3. TRACK: MANUFACTURER'S STANDARD U-SHAPED STEEL TRACK, UNPUNCHED, WITH STRAIGHT FLANGES, COMPLYING WITH <br />ASTM C 955, MANUFACTURER'S STANDARD FLANGE WIDTH, AND MINIMUM UNCOATED -STEEL THICKNESS MATCHING STEEL <br />STUDS. <br />B. JOIST FRAMING: MANUFACTURER'S STANDARD C-SHAPED STEELJOISTS, OF WEB DEPTHS INDICATED, UNPUNCHED, WITH <br />STIFFENED FLANGES, COMPLYING WITH ASTM C 955. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, USE THE FOLLOWING: <br />1. MINIMUM UNCOATED -STEEL THICKNESS: 16 GAUGE 0.0538 INCH. <br />2. FLANGE WIDTH: 1-5/8 INCHES (41 MM), MINIMUM. <br />3. TRACK: MANUFACTURER'S STANDARD U-SHAPED STEEL JOIST TRACK, OF WEB DEPTHS INDICATED, UNPUNCHED, WITH <br />UNSTIFFENED FLANGES, COMPLYING WITH ASTM C 955, AND AS FOLLOWS: <br />a. MINIMUM UNCOATED -STEEL THICKNESS: MATCHING STEELJOISTS. <br />b. FLANGE WIDTH: 1-5/8 INCHES (41 MM), MINIMUM. <br />C. ACCESSORIES: <br />1. FABRICATE STEEL -FRAMING ACCESSORIES OF THE SAME MATERIAL AND FINISH USED FOR FRAMING MEMBERS, WITH <br />MINIMUM YIELD STRENGTH OF 33,000 PSI, OF MANUFACTURER'S STANDARD THICKNESS AND CONFIGURATION, UNLESS <br />OTHERWISE INDICATED. <br />2. EXPANSION ANCHORS: FABRICATED FROM CORROSION -RESISTANT MATERIALS, WITH CAPABILITY TO SUSTAIN, WITHOUT <br />FAILURE, A LOAD EQUAL TO 5 TIMES DESIGN LOAD, AS DETERMINED BY TESTING PER ASTM E 488 CONDUCTED BY A QUALIFIED <br />INDEPENDENT TESTING AGENCY. <br />068316 - FIBERGLASS REINFORCED PANELS <br />A. ACCEPTABLE PRODUCTS: PROVIDE FRPP HAVING UL (ULC) CLASSIFIED CLASS A INTERIOR FINISH MATERIAL PER ASTM E 84, 3/32 <br />(.090) INCH THICK, WITH SIZE OF 4 x 8 FEET OR 4 x 10 FEET. <br />1. CRANE COMPOSITES; FIRE-X GLASBORD WITH SURFASEAL, PRODUCT CODE 6226, CLASS A, WITH EMBOSSED TEXTURE. <br />a. COLOR: #85 WHITE. <br />2. NUDO FIBERLITE FRP PANELS, CLASS A, WITH PEBBLE TEXTURED SURFACE. <br />a. COLOR: 050 WHITE. <br />3. MARLITE STANDARD FRP PANELS, CLASS A, WITH PEBBLE TEXTURED SURFACE. <br />a. COLOR: P199 BRITE WHITE. <br />D. ACCESSORIES: <br />1. ADHESIVE: PROVIDE PANEL ADHESIVE AS RECOMMENDED BY PANEL MANUFACTURER. <br />2. TRIM AND SEAM TREATMENT: EXTRUDED PVC CORNER MOLDINGS, DIVISION BARS, END TRIM AND CAP. <br />a. COLOR: WHITE TO MATCH PANEL COLOR. <br />079200 - JOINT SEALANTS <br />A. INTERIOR JOINTS BETWEEN PLUMBING FIXTURES AND ADJOINING WALLS, FLOORS, AND COUNTERS; AND BETWEEN POLYMER <br />FLOOR BASE AND MIP / FRPP: USE SINGLE -COMPONENT MILDEW -RESISTANT ACID -CURING SILICONE SEALANT. USE WHITE COLOR <br />AT PORCELAIN FIXTURES, GREY COLOR AT STAINLESS STEEL, OR OTHER APPROPRIATE COLOR TO MATCH ADJACENT SURFACE <br />FINISHES. <br />1. ACCEPTABLE PRODUCTS: <br />a. 786 MILDEW RESISTANT (VOC 33 G/L) BY DOW CORNING CORP., 2200 W. SALZBURG ROAD, MIDLAND, MI 48686-0994, PH: <br />(800) 248-2481 OR (989) 496-4400, FAX: (989) 496-4393, HTTP://WWW.DOWCORNING.COM. <br />b. SANITARY SCS1700 (VOC 20 G/L) BY GE CONSTRUCTION SEALANT, 9930 KINCEY AVENUE, HUNTERSVILLE, NC 28078, PH: (800) <br />255-8886 OR (877) 943-7325, FAX: (304) 746-1654, HTTP://WWW.GESEALANTS.COM. <br />2. TYPE AND GRADE: S (SINGLE COMPONENT) AND NS (NONSAG). <br />3. CLASS: 25. <br />4. USE RELATED TO EXPOSURE: NT. <br />092116 -GYPSUM BOARD ASSEMBLIES <br />A. STEEL FRAMING, GENERAL: COMPLY WITH ASTM C 754 AND ASTM C 840 FOR CONDITIONS INDICATED. <br />1. STEEL SHEET COMPONENTS: METAL COMPLYING WITH ASTM C 645 REQUIREMENTS. <br />2. PROTECTIVE COATING: ASTM A 653 / A 653M, G60, HOT -DIP GALVANIZED ZINC COATING. <br />B. INTERIOR GYPSUM WALLBOARD: COMPLYING WITH ASTM C 36/C 36M OR ASTM C 1396/C 1396M, AS APPLICABLE TO TYPE OF <br />GYPSUM BOARD INDICATED AND WHICHEVER IS MORE STRINGENT. <br />1. USE 5/8-INCH THICK, TYPE X, WITH LONG EDGES TAPERED, TYPICAL. <br />C. BEHIND WALL TILE, STAINLESS STEEL WALL LINING, FIBERGLASS REINFORCED PLASTIC PANELS (FRPP) IN FOOD PREPARATION <br />AREAS: PROVIDE 5/8 INCH THICK, GYPSUM FIBER INTERIOR PANELS WITHOUT FACE PAPER. <br />1. ACCEPTABLE PRODUCT: "FIBEROCK BRAND AQUA TOUGH INTERIOR PANELS" MANUFACTURED BY USG. <br />096700 - POLYMER FLOORING <br />A. THE OWNER HAS A NATIONAL ACCOUNT WITH HTI POLYMER, INC. TO SUPPLY ALL PRODUCTS SPECIFIED IN THIS SECTION. <br />HTI POLYMER, INC. <br />18732 142ND AVE NE <br />WOODINVILLE, WA 98072 <br />CONTACT: CHRIS CAMPTON <br />PHONE: (425) 487-8911 / (866) 930-8911 <br />FAX: (425) 487-0915 <br />EMAIL: CHRIS@HTIPOLYMER.COM <br />B. A FOUR -WEEK NOTICE IS REQUIRED PRIOR TO INSTALLATION OF POLYMER FLOORS. <br />C. PF-A: GENERAL POLYMERS FASTOP 12 TC URETHANE CEMENT SYSTEM: <br />1. PENETRATING, MOISTURE TOLERANT TWO -COMPONENT EPDXY WATER EMULSION PRIMER, APPLIED AT 250-300 SQ. FT. / GAL. <br />a. APPROVED PRODUCT: GENERAL POLYMERS 3477. <br />2. THREE -COMPONENT URETHANE CEMENT SLURRY, APPLIED AT 40 SQ. FT. PER MIXED UNIT (NOMINAL 1/4-INCH THICK FOR THIS <br />MORTAR LAYER COMPONENT OF THE SYSTEM). <br />a. APPROVED PRODUCT: GENERAL POLYMERS FASTOP 12 S. <br />3. THREE -COMPONENT URETHANE CEMENT TOPCOAT SEALER, APPLIED WITH A SPRAYER APPARATUS. <br />a. APPROVED PRODUCT: GENERAL POLYMERS FASTOP TC. <br />b. COLOR: MATCH EXISTING. <br />D. HONOR ALL CONTROL JOINTS IN THE CONCRETE SLAB BY CUTTING THROUGH THE URETHANE CEMENT FLOOR AND INSTALLING A <br />JOINT FILLER. <br />a. APPROVED PRODUCT: METZGER MCGUIRE SPAL-PRO RS 88 POLYUREA JOINT' FILLER. <br />b. COLOR: GRAY. <br />097000 - STAINLESS STEEL PANELS <br />A. STAINLESS -STEEL SHEET: USE 20 GAUGE (0.036 INCH) (0.91 MM) ASTM A 666, TYPE 304 STAINLESS STEEL SHEETS. <br />1. GENERAL: COMPLY WITH SSINA'S "FINISHES FOR STAINLESS STEEL" FOR RECOMMENDATIONS FOR APPLYING AND <br />DESIGNATING FINISHES. <br />2. REMOVE TOOL AND DIE MARKS AND STRETCH LINES OR BLEND INTO FINISH. GRIND AND POLISH SURFACES TO PRODUCE <br />UNIFORM, DIRECTIONALLY TEXTURED, POLISHED FINISH INDICATED, FREE OF CROSS SCRATCHES. RUN GRAIN WITH LONG <br />DIMENSION OF EACH PIECE. <br />3. STAINLESS -STEEL FINISHES: <br />a. EXPOSED SURFACES: ASTM A 480 / A 480M, NO. 4 FINISH. <br />b. CONCEALED SURFACES: ASTM A 480 / A 480M, NO. 2B FINISH (BRIGHT, COLD -ROLLED, UNPOLISHED FINISH). <br />4. FABRICATE THE FOLLOWING WALL PANEL JOINT CONNECTORS AND COVERS USING MATCHING MATERIAL: <br />a. PANEL CORNER, CENTER, AND END SLIP JOINTS, CLEATS, AND MOLDINGS <br />b. TOP, BOTTOM, AND END PANEL EDGE COVERS AND FLASHINGS. <br />c. FORMED AND MATCHING END TRIM. <br />099100 - PAINTING <br />A. UN -GALVANIZED AND GALVANIZED STEEL: <br />1. SHERWIN-WILLIAMS: <br />a. FIRST COAT: PRO INDUSTRIAL PRO-CRYL UNIVERSAL WATER BASED PRIMER B66-310 SERIES (2.0-4.0 MILS DRY) (VOC < 100 <br />G/L) <br />b. SECOND AND THIRD COATS: PROMAR 200 ZERO VOC INTERIOR LATEX B31-2600 SEMIGLOSS B31WO2651 (1.6 MILS DRY PER <br />COAT). <br />2, PPG: <br />a. FIRST COAT: 90-912 PITT TECH PLUS DTM ACRYLIC PRIMER (2.0-4.0 MILS DRY). <br />b. SECOND AND THIRD COATS: 6-4510 SERIES SPEEDHIDE INTERIOR ZERO VOC LATEX SEMIGLOSS (1.3 MILS DRY PER COAT). <br />3. COLOR TO MATCH SHERWIN-WILLIAMS SW 7030 "ANEW GRAY". <br />B, GYPSUM WALLBOARD: <br />1. SHERWIN-WILLIAMS: <br />a. FIRST COAT: PROMAR 400 ZERO VOC INTERIOR LATEX PRIMER B28WO4600 (1.1 MILS DRY PER COAT). <br />b. SECOND AND THIRD COATS: PROMAR 200 ZERO VOC INTERIOR LATEX B20-2600 EG-SHEL B20W12651 (1.7 MILS DRY PER <br />COAT). <br />2. PPG: <br />a. FIRST COAT: 6-2 SPEEDHIDE INTERIOR LATEX PRIMER (1.2 MILS DRY) (VOC < 46 G/L). <br />b. SECOND AND THIRD COATS: 6-4310 SERIES SPEEDHIDE INTERIOR ZERO VOC LATEX EGGSHELL (1.5 MILS DRY PER COAT) (VOC <br />0 G/L). <br />3. COLOR OF GENERAL WALLBOARD APPLICATIONS: COLOR TO MATCH SHERWIN-WILLIAMS SW 7003 "TOQUE WHITE", EXCEPT <br />WHERE NOTED ON DRAWINGS. <br />www.ctagroup.com <br />800,757.9522 <br />© 2018 I ALL RIGHTS RESERVED <br />DRAWN BY I CHUDY <br />CHECKED BY I BRENNAN <br />REVISIONS <br />6 05r9/2019 <br />NEW OPT 3 PLAN <br />06,29.17 11:08 PM I L:\COSTC0\0114 Everett, WAOMCAD Arch\114_G2.dwig <br />