My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 19TH AVE SE 2019 Plans 2022-12-07 (2)
>
Address Records
>
19TH AVE SE
>
10200
>
Plans
>
10200 19TH AVE SE 2019 Plans 2022-12-07 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2022 8:56:50 AM
Creation date
6/21/2022 4:00:13 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10200
Permit
B1901-007
Year
2019
Notes
RENOVATE FRESH MEAT & DELI, ADD EXT REFRIGERATION RM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AyrCONSTRUCTION <br />NOTES <br />.C3'E <br />1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK BEING IMPOSSIBLE TO INTERRELL <br />ARCHITECTS E140INEEPS <br />DETAIL AND SPECIFY. IT IS THEREFORE - RESPONSIBILITY - <br />HE ELECTRICAL CONTRACTOR TO CAREFULLY <br />EXAMINE - BUILDING .4 <br />ND FAMILIARIZE HIMSELF WITH THE CONDITIONS AS RELATED TO THE PROPOSED WORK. <br />2. ELECTRICAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE DRAWINGS BEFORE PROCEEDING WITH ANY www.ctagroup.com <br />WORK. IT IS THE. RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ESTABLISH DIMENSIONAL CONTROL LINES FOR 8 0 0.7 5 7 : 9 5 2 2 <br />HIS SUB -CONTRACTORS TO CHECK THEIR LAYOUT WORK RELATIVE TO NEW WALLS AND THE WORK OF OTHER <br />SUBCONTRACTORS. REPORT ANY PLAN CONFLICTS OR DISCREPANCIES TO ARCHITECT/ENGINEER, WITH COPIES TO <br />COSTCO'S PROJECT MANAGER AND COSTCO'S CONSTRUCTION MANAGER, FOR CLARIFICATION. ANY REMEDIAL <br />WORK REQUIRED AS A RESULT OF NOT FOLLOWING THESE PROCEDURES SHALL NOT ENTITLE THE GENERAL <br />CONTRACTOR OR ELECTRICAL CONTRACTOR TO ANY ADDITIONAL COMPENSATION, <br />3. ALL WIRING FOR CIRCUITS TERMINATING 75' OR MORE FROM PANEL SHALL BE SIZED NOT LESS THAN #10 AWG. <br />4. ALL ELECTRICAL EQUIPMENT AND RECEPTACLES SHALL HAVE GROUNDED TYPE SERVICES, <br />6, ALL CONDUCTORS ABOVE SIZE #6 SHALL BE THVV. <br />7. ALL NEW CIRCUITS SHALL BE RUN OVERHEAD UNLESS NOTED OR INDICATED OTHERWISE. <br />3. ELECTRICAL CONTRACTOR MAY REUSE EXISTING ELECTRICAL STUB -UPS IF FOUND TO BE ACCEPTABLE SIZE AND <br />LOCATION, <br />9, ALL ELECTRICAL WORD SHALL CONFORM TO CODES. <br />'10. ELECTRICAL CONTRACTOR TO FIELD CONFIRM LOCATION D USE OF ALL CIRCUITS IN REVISED PANELS. <br />NEWTYPED DIRECTORIES <br />LABELSDISCONNECT SWITCHES, CONTACTORS, ETC. DYMO TYPE "STICK ON" P <br />MISSING OR LOOSE COVERS. <br />11. ANY ELECTRICAL WORD WHICH SHALL INTERFERE WITH NORMAL OPERATION SHALL BE DONE AFTER <br />STORE HOURS. <br />12. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL SERVICE TO REFRIGERATION UNITS AND OTHER <br />AREAS OF WORK AS NECESSARY. <br />13. REFRIGERATION RACK AND/OR CONDENSER UNIT DESIGNATIONS ARE FOR REFERENCE ONLY. EXACT LOCATION AND <br />ORIENTATION SHALL BE FIELD VERIFIED PRIOR TO PERFORMING WORK. <br />ALL FURNISH AND INSTALL ALL CONDUIT, <br />-BOXES AND CABLES AS REQUIRED <br />TERMINATIONREFRIGERATION/EMS CONTROL INCLUDING LEAK DETECTION SYSTEM. SEE REFRIGERATION AND EMS DRAWINGS <br />FOR CONDUIT ROUTING AND CABLE <br />PROVIDE SUFFICIENT SLACK CONDUCTOR AT EACH END FOR <br />BAR JOIST HEIGHT, THEN HOMERUN. PROVIDE A <br />CABLES.COMPLETE�RACEVVAY SYSTEM FOR ALL LOWVOLTAGE <br />AREAS16. PATHS OF EGRESS FROM 4 FLOOR _. <br />RE INDICATED ON THE OVERALL <br />LAN <br />ON SHEET Gl. VERIFY THAT EXISTING ILLUMINATED EXIT SIGNS AND EMERGENCY EGRESS LIGHTING FOR THE <br />PATHS OF EGRESS COMPLY WITH CODE. UPGRADE 1r REPLACE ANY DAMAGED DEFICIENT ILLUMINATED - <br />SIGNS AND EMERGENCY EGRESS LIGHTING AS NECESSARY FOR CODE COMPLIANCE. <br />XIT <br />I INSTALL 3/4"C FOR LOW VOLTAGE CABLES FROM REFRIGERATION CASE/COOLER/FREEZER TO <br />(D REFRIGERATION SYSTEM SHOWN OR REMOTE REFRIGERATION CONTROL PANEL.. <br />EXISTING EQUIPMENT/FIXTURE TO BE RELOCATED. EXTEND EXISTING CONDUIT AND CONDUCTORS AS <br />REQUIRED AND RECONNECT EQUIPMENT/FIXTURE. PROVIDE NEW HARDWARE AS NECESSARY. <br />INTERCEPT EXISTING CIRCUIT(S) AND EXTEND TO NEW/REPLACEMENT EQUIPMENT. EXTEND EXISTING <br />NEW CONDUIT AND CONDUCTORS AS REQUIRED AND RECONNECT EQUIPMENT. PROVIDE NEW HARDWARE AS <br />NECESSARY. COORDINATE CONTROL WITH REFRIGERATION CONTRACTOR. <br />S E 1 <br />NEW DUAL -LEVEL, EXTENDED COVERAGE OCCUPANCY SENSOR SUITABLE FOR COOLER -SOX USE. MATCH <br />446 SF EXISTING SOX OPERATION. <br />I' NEW HEATED PREP SLIDING WINDOWS TO REPLACE EXISTING. PRESERVE EXISTING CONNECTIONS AND0 <br />i I E EXTEND TO NEW. PROVIDE NEW HARDWARE AS NECESSARY. <br />II I� <br />�= NEW KITCHEN HOOD TO REPLACE EXISTING. PRESERVE EXISTING CONNECTIONS AND EXTEND SHUTDOWN <br />If INTERLOCK TO NEW ROTISSERIE OVENS AND ANY OTHER NEW EQUIPMENT INSTALLED UNDER HOOD. <br />m PROVIDE NEW HARDWARE AS NECESSARY. <br />, SE_ co > <br />� I <br />l NEW LIGHTING TO REPLACE EXISTING 1:1. PRESERVE EXISTING CONNECTIONS AND EXTEND TO NEW LIGHT Lo <br />FIXTURES. PROVIDE NEW HARDWARE AND MATERIALS AS NECESSARY. 0 <br />I00 <br />f <br />LIGHTINGRSCHEDULE w <br />ALL LICIT FIXTURES S....11_ HAVE FACTORY !NSTALLEED DISCONNECTEDMEANS PER LATEST NEC CODE <br />TYPE MANUFACTURER CRIPTIC P CUNT, WATT REMARKS <br />CREE CP'r` ®A -DI - - m L-WH-400CK- CCRI WITH E SURFACE 6 VERIFY EXACT FIXTURE WITH REFRIGERATION <br />COMPOSITE BOLT REFRIGERATION KIT CONTRACTOR. <br />�- <br />0 <br />SYMBOL LEGEND. 0 d <br />C) T- <br />NEW <br />(D) DEMOLITION <br />(R) RELOCATED <br />J ELECTRICAL JUNCTION SOX <br />REFRIGERATION TEMPERATURE PROBE <br />(WIRED BY OTHERS) 431 <br />ELECTRICAL CONDUIT <br />os OCCUPANCY SENSOR SWITCH: 22�019 <br />O 2018 ALL RIGHTS RESERVED <br />12.14.2018 <br />DRAWN BY I RANSOM <br />CHECKED BY I GLASSING <br />REVISIONS <br />i I 1I �1 al <br />LIGHTING <br />PLAN <br />J <br />L:\C0STC0M14 Everett, VVA\BIMCAD\EIac\01 i4_E101 PWR LTG PLAN. DVVG <br />
The URL can be used to link to this page
Your browser does not support the video tag.