Laserfiche WebLink
DI <br />............................... _.. <br />ICI <br />I B I <br />I A I <br />L1 <br />17@9.2=156`-33/4" <br />TYR <br />A ¢n csa n_ �iwo <br />1 2 3 4 <br />5 <br />General Notes - Floor Plans <br />A. EXTERIOR DIMENSIONS ARE TO THE OUTSIDE FACE OF CONCRETE <br />FOUNDATION WALLS, FACE OF MASONRY WALLS, OR FACE OF SHEATHING <br />UNLESS OTHERWISE NOTED. DIMENSIONS TO MASONRY UNITS ARE NOMINAL <br />UNLESS OTHERWISE NOTED. <br />B. ANGLES ARE 30 DEGREES, 45 DEGREES, OR 90 DEGREES U.N.O. <br />C. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS AT FIRE RATED WALLS, <br />INCLUDING BUT NOT LIMITED TO PIPING, DUCTS, CONDUIT, ETC., WITH <br />FIRESTOPPING PER I.B.C. REQUIREMENTS. <br />D. RESTRIPE EXISTING PARKING LINES AND STALL NUMBERS ON ALL ABOVE <br />GRADE LEVELS. <br />E. REMOVE WHEEL STOPS AS REQUIRED FOR INSTALLATION OF TRAFFIC COATING <br />ON UPPER LEVEL. <br />F. REPLACE EXISTING EXPANSION JOINT BETWEEN GRIDLINES 11 AND 12 AT ALL <br />ABOVE GRADE LEVELS. <br />G. IEBC CHAPTER 3 COMPLIANCE METHOD TO BE 301.1.2 - WORK AREA <br />COMPLIANCE METHOD. WORK UNDER THIS PROJECT IS CLASSIFIED AS A LEVEL <br />1 ALTERATION PER IEBC 503.1 (CHAPTER 7). <br />H. PROJECT SCOPE CONSISTS OF REPLACEMENT OF THE UPPER LEVEL PARKING <br />DECK COATING AND REPAIRS TO EXISTING REINFORCED CONCRETE SLABS, <br />BEAMS, AND COLUMNS. <br />- n - <br />J <br />MARK DATE DESCRIPTION <br />