Laserfiche WebLink
SOUND BATT <br />NEW OR EXIST. INSUL. <br />TJI'S OR 2X WHERE OCCURS G 2X STUDS 5/8" <br />GYPSUM BOARD <br />JOIST OR BOTH SIDES W/ (E) BATT INSUL. <br />RAFTER, OR WOOD STUDS + , <br />STUD WALL PER LEGEND TRUSS, TYP. PER OPTIONAL R-10 INSUL. <br />WALL LEGEND <br />GYP. BD. 4x8 DF#2 HEADER <br />1/2" GYP. BD. <br />4'-0" 4 FLAT <br />NAILING AS REQUIRED 2x@ EA. <br />O•C SIDE 3/4"x3 1/2" MEDIUM <br />BOTTOM PLATE DENSITY FIBERBOARD TRIM <br />BASE EA. SIDE, TYP. w/ 1/8" RADIUS CORNERS <br />O <br />U N <br />SHIM (FILL CAVITY 0 <br />5/8" GYP. BD. CEIL., TYP. w/INSULATION) q <br />SUB FLOOR PER STRUCT. PRES. N <br />TREATED 2X m <br />JOISTS PER STRUCT. WALL PER <br />PLATE WOOD FRAME 1= <br />rf I - <br />LEGEND .145" DIA. POWDER w z <br />w <br />DRIVEN PINS @ 18" W Z M <br />O.C. DOOR - SEE SCHED. W u <br />.,n <br />CONC. SLAB, TYP. q <br />�N� <br />wNN <br />m OHn <br />WALL -FL. PERR WALL - FL. PARALLEL WALL-SL&ABODET,o� w_ N1 1/2" = 1'-0" "_ ,,2 INT3 3"=11-011 4. DOOR HEAD. A ° <br />��,k <br />LEI 12- OJr <br />aW Z�z� <br />DUAL GLAZED DBL. 2x FRAMING v w q 5 <br />VINYL @WINDOW w O 3 H N <br />WINDOW SYSTEM JAMB. <br />WINDOW C CORNER BEAD w N LD <br />HEADER EXTERIOR SIDING PER WALL CORNER BEAD SHIM AS REQ'D. Of 0 <br />(SEE LEGEND/ELEVATIONS 1/2" GYP. BD, Q m 0 3 <br />N <br />SHIM AS REQ'D. <br />STRUCT.) SOLID WALL O <br />SHEATHING <br />ce-af <br />(SEE SEALANT W/ SOLID WALL SILL O <br />STRUCT.) BACKER SHEATHING BELOW <br />A ROD (SEE w <br />BUTYL RUBBER FLASHING DBL. 2x FRAMING STRUCT.) <br />1/2" GYP. BD. ( W/ SELF-ADHESIVE LL <br />BACKING. APPLY OVER @ WINDOW O z <br />INFILTRATION BARRIER I JAMB. o <br />I AS SHOWN, BUTYL RUBBER FLASHING W/ SELF <br />SE ADHESIVE BACKING. APPLY OVER WALL PER p o <br />SEALANT AS REQ D. INFILTRATION BARRIER AS SHOWN. LEGEND <br />26GA. GALV.v co <br />— — — — — — — — — — — — o LU_ <br />HEAD <br />FLASHING 1/2" GYP. BD. o 0 <br />EXTERIOR SIDING PER j z <br />CORNER SHIM AS NECESSARY l SOLID WALL SHEATHING (SEE WALL _ O <br />BEAD Q STRUCT.) LEGEND/ELEVATIONS <br />p <br />DUAL GLAZED / DUAL GLAZED WALL PER LEGEND BUTYL RUBBER O <br />VINYL <br />VINYL w <br />,� <br />WINDOW SYSTEM FLASHING WINDOW SYSTEM < ° <br />w <br />W/ SELF-ADHESIVE <br />EXTERIOR SIDING PER BACKING. APPLY OVER v ir <br />WALL SEALANT W/ w O <br />INFILTRATION BARRIER LEI <br />LEGEND/ELEVATIONS AS SHOWN. RODKERco <br />WINDOW HEADER WINDOW SILL WINDOW JAMB Qw <br />5 3" = 1'-0" 6 3" = 1'-0" 7 z N <br />3" = 1'-0" Q O <br />o¢ <br />P: z <br />C) <br />wo <br />t- <br />Ow <br />LL <br />►— O <br />0 U <br />Fr 4 <br />- HEAD FLAP FOLDED DUPONTTM TYVEK"TAPE a O <br />OVER HEAD FLASHING. <br />_. OPTIONAL BACKDAM DETAIL PEEL LARGEST STRIP OF I HEAD FLAP FOLDED OI— <br />n 0 WHEN USING9"WIDE RELEASE PAPER FIRST, i UPWARD TO EXPOSE U 0 <br />ft - HEAD DUPDNrTMFLExwRAPTM NP <br />a0 SHEATHING. O <br />0 0 FLASHINGuE.�E, f 1— <br />-' �... . o � ®. EXPOSED O <br />�� :?' ►y, U SHEATHING. _ w a <br />e d I <br />DUPONT- TYVEI4®TAPE <br />0 O D 0 p <br />I <br />O a 0 Li>_ <br />} <br />I <br />- 0 <br />(311 <br />iii CORNERS � ( (� Z <br />o Q CV s6A / O SILL w o <br />im <br />Rt <br />a 1- <br />0 0 0 O 0 I- <br />0 wLLJ <br />uj <br />� I— <br />�'{�,,_ <br />STEP 16 STEP 15 STEP 14 - STEP 8 STEP 7 o STEP 6 STEP 5 0 Q _ > <br />STEP 17 - � z W w <br />A. TAPEALL CUTS IN DUPONTT TYVE0WRBAND ;APE A. TRIM THE 0 A. FLIP DOWN UPPER FLAP OF 0 A. INSTALL THE SILL FLASHING. REMOVE THE 0 A. PREPARE THE SILL FLASHING BYCUTTING A 0 A. FLIP THE CUT HEAD FLAP UPWARD TO <br />A. FOLD SIDE FLAPS INTO ROUGH - J <br />A. INSTALL DUPONTT" RESIDENTIAL SEALANT OR - ACROSS HEAD OF THE WINDOW WITH DUPONT- TYVEK° WRB 1"-2 ABOVE THE DUPONT- TYVEKt WRB SO IT LAYS FLAT LARGEST STRIP OF RELEASE PAPER, ALIGN PIECE OF DUPONTTM FLEXWRAPTN NF THAT IS I EXPOSE THE SHEATHING AND OPENING AND SECURE TO INSIDE CL <br />RECOMMENDED SEALANT (AND BACKER ROD AS DUPONT(TM) TYVEK(R) TAPE, 4" DUPONT- FLASHING WINDOW OPENING. ACROSS THE HEAD FLASHING, THE FLASHING WITH THE INTERIOR EDGE OF ATLEAST 12" LONGER THAN THE SILL LENGTH. TEMPORARILY SECURE WITH p O <br />NECESSARY) AROUND THE WINDOW OPENING AT THE TAPE OR DUPONTT" STRAIGHT FLASHT". B. WHEN TRIMMING THE SILL AND INSTALL INTO ROUGH OPENING B. USE 6" DUPONTi°^ FLEXWRAP' NF DUPONTT� TYVEK®TAPE. WALL,TYVES TAPE OR TOINSIDEWALL WITH W Y M Z <br />INTERIOR. IT IS ALSO ACCEPTABLE TO USE DUPONT— TYVEKV—WRB, DO NOT CUT OR ACROSS SILL AND UP JAMBS (6'MIN.). FOR Tx 4" FRAMING TM � w p W 0 <br />DUPONT TYVEK WRAP CAP W <br />DUPONT WINDOW AND DOOR FOAM OR RECOMMENDED DAMAGE THE HEAD FLASHING THAT HAS B. APPLY WORKING FROM THE MIDDLE OF THE AND 9" DUPONTTM FLEXWRAPTI NF FASTENERS H Q <br />FOAM AT THE INTERIOR CAVITY OF THE JAMBS AND HEAD. BEEN INSTALLED BEHIND IT. SILL TOWARDS THE SIDES. SECURE FOR 2"x 6" FRAMING. <br />IF FOAM IS USED AT THE SILL, RECOMMENDED SEALANT DUPONT1m FLEXWRAPTM NF TIGHTLY INTO C. INSPECT INSTALLATION SURFACE TO ENSURE <br />SHOULD BE USED AT THE SILL AREA BEHIND THE EDAM THE CORNERS BY FIRST WORKING IN ALONG THE SURFACE IS FREE OF DIRTAND V <br />TO ENSURE A PROPER WATER SEAL THE SILL BEFORE ADHERING UP THE JAMBS. LL <br />SUBSTANCES THAT COULD INTERFERE WITH LL <br />C. DO NOT STRETCH MATERIAL ALONG THE SILL ADHESION AS WELL AS ANY SHARP Lli <br />OR JAMBS. PROTRUSIONS. <br />Lo <br />oo T. SHEATHING INSTALLED W 0 <br />ouaafr^ FusnxaTnPewtrrtnPs OVER BARE STUDS N <br />ouPonT�^ FIFXMUP^ w <br />0 G 0 DUPONTN TYVE0 WRB <br />r- ® 0 0 SHEATHING FASTENERS BARE STUDS11i4(� <br />ft <br />C 0 C 0 ©® DUPONTT. TYVEe WRAP CAP FASTENERS OUTLINE OF ROUGH --I <br />0 WINDOW TO BE — a ROUGH OPENING OPENING TO SE CUT LV <br />iucomxecr INSTALLED ITT OUTLINE EXTERIOR <br />ouPcur«Fws„xoTaPe FwNx ivrrn n _ e G FOR WINDOW. <br />z �t1MIX FIfXNAAP^NF INSTALLED <br />i <br />��`_ ) -- -- -- -- -- - -- -- -- U <br />Lij <br />ouPcwT^ F�rnxxnP^NFntvewse DUPONTTM TYVE0WRB I a �/ Z <br />/ DO 0 "I DIRECTION OF ( � <br />0 0 T I I" POSITIVE DRAINAGE 0 <br />0 0 o I a I I ( FLOW. INTERIOR Q — <br />�, _ a 0I �_ u� <br />-- -- -- -- ---�-- - -- -- - -- -- -- a w <br />\(\ 0 I 0 \ I Lu <br />7 0 o o 0 ° Z <br />a � O z� w (- <br />STEP 13 STEP 12 STEP 11 0 STEP 10 STEP 9 0 v Q Lwu <br />STEP 4 0 STEP 3 STEP 2 STEP 1 >' n o <br />A. CUT A PIECE OF A. CUT TWO PIECES OF 0 A. INSTALL WINDOW ACCORDING TO p A. 0 A. REMOVE NARROW PIECE OFTHE RELEASE C0 V <br />DUPONTTm STRAIGHTFLASHT , DUPONT a FLASHING DUPONTTM FLASHING TAPE OR MANUFACTURER'S INSTALLATION APPLY (CONTINUOUSLY} DUPONT " RESIDENTI PAPER. a ® 0 w <br />A. CUT AN "I CUT° (STANDARD I -CUT} IN 0 A. DUPONTTm TYVEK WRB TO BE D A. SHEATHING TO BE INSTALLED OVER BARE <br />TAPE FOR HEAD FLASHING, DUPONTT" STRAIGHTFLASHT FORJAMB INSTRUCTIONS. SEALANT OR RECOMMENDED SEALANT ON B, FAN DUPONTTN FLEXWRAPT NFATBOTTOM Tx BARE STUDS PRIOR TO SHEATHING INSTALLATION. O Ix <br />THE DUPONT TYVEK INRB. MECHANICALLY FASTENED AND INSTALLED STUDS. SLOPE SILL FRAMING TO EXTERIOR. FRAMING AND B. HEAD FLASHING TO EXTEND BEYOND FLASHING EXTENDING I "ABOVE WINDOW THE HEAD AND JAMBS OF ROUGH OPENING CORNERS AND ADHEREONTOEXTERIOR B. CUT HEAD FLAP AT A 45 ANGLE TO OVER SHEATHING. B. AFTER SHEATHING HAS BEEN INSTALLED, CUT W N <br />(ON TOP OF WRB), FACE OF WALL. COVERAGE SHOULD BE 2" EXPOSE 8' OF SHEATHING TO ALLOW B. DO NOT INSTALL FASTENERS WITHIN 6" OF AN OPENING IN THE SHEATHING ALONG THE SHOWN SCHEMATICALLY, <br />COMPONENTS ARE ONLY <br />OUTER EDGES OF JAMB FLASHING. HEAD FLANGE AND 4"T06" BELOW0 <br />Q <br />C. REMOVE RELEASE PAPER AND INSTALL BOTTOM EDGE OF SILL FLASHING. B. IF SEALANT IS APPLIED TOTHE SILL, TO 3" INCHES ONTO THE FACEOF THE WALL FOR HEAD FLASHING INSTALLATION. THE SILLS AND JAMBS OF THE OPENINGS PERIMETER OF THE ROUGH OPENING FOR SHOWN SCHEMATICALLY. SEE DRAWINGS BY <br />COMPLETELY COVERING WINDOW B. REMOVE RELEASE PAPER AND PRESS ENSURE THAT THERE ARE AT LEAST TWO C. PRESS SILL FLASHING W1 FIRM HAND OTHERS FOR DETAILED INFORMATION. U <br />AND WITHIN 9" OF THE HEAD OPENINGS. WINDOW. M <br />MOUNTING FLANGE AND ADHERING TO THE TIGHTLY ALONG SIDES OF WINDOW (2) 2" INCH GAPS IN THE SEALANT BEAD FOR PRESSURE OR J-ROLLER TO ENSURE FULL C. ENSURE THE SHEATHING IS CUT FLUSH WITH 04 t- <br />EXPOSED SHEATHING. FRAME. EVERY 4' OF WINDOW TO ALLOW FOR ADHESION ON ALL SURFACES, OR SLIGHTLY BELOW THE SILL FRAMING TO _ <br />qy <br />DRAINAGE. <br />ALLOW FOR POSITIVE DRAINAGE. r U <br />� q <br />TYP. WINDOW FLASHING o W <br />8 1 1/2" = 1'-0" W Q t3� O <br />N Q V <br />