BUILDING CODE <br />2015 INTERNATIONAL BUILDING CODE <br />DECK LOAD <br />DEAD LOAD : 10 psf <br />LIVE LOAD: 60 psf <br />SNOW LOAD: 25 PSF <br />ROOF LOAD <br />DEAD LOAD: 15 psf <br />FLAT ROOF SNOW LOAD: 25 psf <br />SNOW EXPOSURE FACTOR (Co): 1.1 <br />SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 <br />THERMAL FACTOR (Ct): 1.1 <br />WIND DESIGN DATA <br />1. BASIC WIND SPEED: 110 MPH <br />2. WIND IMPORTANCE FACTOR (Iw): 1.0 <br />BUILDING CATEGORY: II <br />3. WIND EXPOSURE: C <br />4. Kzt = 2.0 <br />5. INTERNAL PRESSURE COEFFICIENT: NA <br />6. APPLICABLE WIND PRESSURE FOR <br />COMPONENTS AND CLADDING: NA <br />SESIMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: 1.0 <br />SEISMIC USE GROUP: I <br />2. SPECTRAL RESPONSE ACCELERATION (Ss): 135.1 % G <br />3. SITE CLASS: D (ASSUMED) <br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 86.4%G <br />5. SEISMIC DESIGN CATEGORY: D <br />6. BASIC SEISMIC -FORCE -RESISTING SYSTEM: SHEARWALLS & EMB. POST <br />7. DESIGN BASE SHEAR: SEE CALCULATIONS <br />8. SEISMIC RESPONSE COEFFICIENT (Cs): <br />SHEARWALLS=0.133, EMB. POST=0.576 <br />9. RESPONSE MODIFICATION FACTOR (R): 6.5 <br />10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE <br />FRAMING LUMBER <br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NOA FOR POSTS, BEAMS, <br />AND HEADERS; HEM -FIR NO.2 FOR 2X AND 3X JOISTS, AND STUDS; AND <br />HEM -FIR NO.2 FOR ALL TOP AND BOTTOM PLATES (GRADES ARE TYPICAL <br />UNLESS OTHERWISE NOTED ON PLANS). LUMBER TO BE GRADE MARKED PER <br />WCLIB SPECIFICATIONS. <br />2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, EXPOSURE 1 <br />SHEATHING CONFORMING TO EITHER COMMERCIAL STANDARDS DOC PS 1 OR <br />PS 2. PROVIDE MINIMUM OF 3/8" EDGE DISTANCE ON ALL NAILS AND A 1/8" <br />EXPANSION JOINT BETWEEN ALL PANEL EDGES. MINIMUM SHEATHING <br />REQUIREMENTS ARE AS FOLLOWS: <br />ROOF SHEATHING TO BE 15/32" C-D INT-APA RATED PLYWOOD WITH <br />EXTERIOR GLUE, P.I. 24/16 (USE 5-PLY FOR PANELIZED ROOFS). <br />NAIL WITH 8d NAILS AT 6" ON CENTER AT PANEL EDGES AND 12" ON <br />CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE. <br />SUB FLOORING TO BE 3/4" T&G C-D INT-APA RATED PLYWOOD WITH <br />EXTERIOR GLUE, P.I. 48/24. GLUE AND NAIL WITH 10d NAILS AT 6" <br />ON CENTER AT PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE <br />SUPPORTS UNLESS NOTED OTHERWISE. <br />3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE INTERNATIONAL <br />BUILDING CODE UNLESS NOTED OTHERWISE. USE COMMON NAILS THROUGHOUT <br />UNLESS NOTED OTHERWISE. <br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS <br />SPECIFICALLY DETAILED OR APPROVED IN WRITING BY THE STRUCTURAL <br />ENGINEER. <br />5. USE DOUBLE JOISTS UNDER WALLS OR PARTITIONS PARALLEL TO JOISTS <br />UNLESS SPECIFICALLY NOTED OTHERWISE. USE SOLID BLOCKING UNDER <br />PARTITIONS PERPENDICULAR TO JOISTS. <br />6. RIM JOIST ARE 14" LSL OR 2x SOLID SAWN LUMBER AS MINIMUM. <br />7. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL <br />STRUCTURAL MEMBERS. <br />8. PROVIDE 2X2 WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG <br />SCREWS BEARING ON WOOD. <br />9. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS <br />OTHERWISE NOTED. LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% <br />OF THE NOMINAL DIAMETER OF THE LAG BOLT UNLESS OTHERWISE NOTED. <br />10. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" <br />MINIMUM DIAMETER BOLTS SPACED AT 48" O.C. MAXIMUM SPACING (EMBED 7" <br />MINIMUM INTO CONCRETE OR MASONRY). SEE PLANS AND DETAILS FOR <br />SPECIFIC REQUIREMENTS WHERE OCCUR. <br />11. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL <br />BE PRESSURE TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION). <br />ALL FOUNDATION BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZEDED, <br />OR Z-MAX COATING TO PROTECT FROM OXIDATION. <br />12. FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE <br />PRESERVATIVELY TREATED WOOD SHALL BE RETREATED IN THE FIELD IN <br />ACCORDANCE WITH AWPA M4. IRC 320.3.1 <br />13. 2X4 RAFTERS EXCEPT WHERE SPECIFICALLY DETAILED SHALL NOT <br />SUPPORT SUSPENDED CEILINGS, SPRINKLERS, DROP SOFFITS, OR ANY OTHER <br />ELEMENTS. <br />14. WIRE STAPLES MAY BE SUBSTITUTED FOR DIAPHRAGM AND SHEARWALL <br />NAILING WHEN APPROVED BY THE STRUCTURAL ENGINEER. <br />15. EXTERIOR STUD WALLS SHALL BE 2X6 @ 16" O.C.. UNLESS NOTED <br />OTHERWISE. INTERIOR STUD BEARING WALLS SHALL BE CONSTRUCTED USING <br />2X4 @ 16" O.C. AT UPPER TWO FLOORS AND EITHER 2X6 @ 16" O.C. OR <br />3X4 @ 16" O.C. BELOW TOP TWO FLOORS. STUD NONBEARING WALLS SHALL <br />BE CONSTRUCTED USING 2X4 @ 24" O.C.. UNLESS NOTED OTHERWISE. SEE <br />NOTE 1 FOR LUMBER GRADES OF STUDS AND PLATES. <br />16. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, <br />OR APPROVED EQUAL. APPROVAL MU <br />ST BE OBTAINED IN WRITING PRIOR TO <br />INSTALLATION. FILL ALL FASTENER HOLES WITH FASTENER TYPES (NAILS, <br />BOLTS, ETC.), SIZES, AND QUANTITIES AS SPECIFIED BY THE MANUFACTURER. <br />17. ALL HEADERS SHALL BE 4X8 DF#2 UNLESS OTHERWISE NOTED ON THE <br />DRAWINGS <br />18. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR <br />PLYWOOD USED IN SHEAR PANELS. <br />19. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE <br />DETAILS AND NOTES. <br />SPECIAL INSPECTIONS <br />SPECIAL INSPECTIONS SHALL BE CONDUCTED IN ACCORDANCE WITH THE 2015 <br />IBC, CHAPTER 17. SPECIAL INSPECTION SHALL BE PROVIDED FOR: <br />- SEISMIC FORCE RESISTING SYSTEMS REQUIRING INSPECTION (IBC 1705.11) <br />STRUCTURAL CONCRETE AND REINFORCEMENT STEEL <br />- STRUCTURAL WOOD (1705.11.2) <br />GRADING, EXCAVATING, AND FILLING (SOILS 1705.6) <br />- OTHER INSPECTIONS AS REQUIRED BY THE DESIGN PROFESSIONAL OR <br />BUILDING OFFICIAL (1705.1.1) <br />- LATERAL RESTRAINT SYSTEM <br />- ANCHOR BOLTS IN CONCRETE <br />CONT. SPECIAL INSPECTION FOR POST INSTALLED ANCHORS <br />ROOF TRUSS <br />1. THE TRUSSES SHALL BE DESIGNED BY THE FABRICATOR TO FIT DIMENSIONS <br />AND LOADS INDICATED ON THE PLANS AND IN THE STRUCTURAL NOTES. ALL <br />DESIGNS SHALL BE IN ACCORDANCE WITH ALLOWABLE VALUES ASSIGNED BY <br />THE BUILDING CODE. CONCENTRATED MECHANICAL ROOF LOADS SHALL BE <br />INCLUDED IN THE DESIGN. VERIFY WEIGHTS AND LOCATIONS WITH THE <br />ARCHITECT. SHOP DRAWINGS MUST BE RETAINED AT THE JOB SITE AND <br />AVAILABLE TO THE BUILDING INSPECTOR FOR REFERENCE. THE TRUSS <br />CALCULATION PACKAGE SHALL BE DESIGNED UNDER THE DIRECT SUPERVISION <br />OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE <br />TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL <br />SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT <br />PLANS AND THE TRUSS DESIGN DRAWINGS. <br />2. SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED TO THE <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION. DRAWINGS AND <br />CALCULATIONS SHALL BE STAMPED AND SIGNED BY A REGISTERED <br />PROFESSIONAL ENGINEER. THE DRAWINGS SHALL SHOW ALL CRITICAL <br />DIMENSIONS AS WELL AS THE LOADS THE TRUSSES ARE DESIGNED TO <br />SUPPORT. BRIDGING BETWEEN TRUSSES, CONTINUOUS LATERAL BRACING, AND <br />DIAGONAL BRACING SHALL BE SPECIFIED BY THE TRUSS MANUFACTURER IN <br />ORDINACE WITH TRUSS PLATE INSTITUTE RECOMMENDATIONS. SHOP DRAWINGS <br />MAY CONTAIN THE MANUFACTURERS ENGINEERING RESPONSIBILITY <br />LIMITATIONS. HOWEVER, THEY SHALL MAKE NO STATEMENT AS TO THE <br />ENGINEER OF RECORD RESPONSIBILITIES. <br />3. THE TRUSSES ARE TO BE ERECTED AND INSTALLED IN ACCORDANCE WITH <br />THE PLANS, APPROVED FABRICATOR DRAWINGS, AND INSTALLATION <br />SUGGESTIONS. CONTRACTOR SHALL GIVE NOTIFICATION PRIOR TO ENCLOSING <br />THE TRUSSES TO PROVIDE AN OPPORTUNITY FOR INSPECTION OF THE <br />INSTALLATION. <br />FOUNDATIONS <br />1. THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE <br />INTERNATIONAL BUILDING CODE TABLE 1804.2. FOUNDATION WORK SHALL BE <br />PERFORMED IN ACCORDANCE WITH CHAPTER 18 OF THIS CODE. <br />2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: <br />ALLOW. SOIL BEARING = 1500 PSF <br />SOIL FRICTION = .25 <br />EQUIV. FLUID PRESSURES: <br />*ACTIVE PRESSURE = 35 PCF <br />PASSIVE PRESSURE= 150 PCF <br />*(WALLS RESTRAINED AGAINST ROTATION SHALL BE DESIGNED FOR <br />D PRESSURE OF 55 PCF AN EQUIV. FLUID ). <br />3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18" BELOW THE <br />UNDISTURBED GROUND SURFACE OR TO FROST DEPTH. ALL FOOTINGS SHALL <br />BE FOUNDED ON COMPACTED FILL OR UNDISTURBED NATURAL GRADE UNLESS <br />OTHERWISE NOTED. <br />4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST <br />OF THE EXCAVATED MATERIAL AND/OR IMPORTED BORROW AND SHALL BE <br />FREE OF ORGANIC MATTER, TRASH, LUMBER, OR OTHER DEBRIS. ALL WALLS <br />SHALL BE ADEQUATELY BRACED PRIOR TO BACKFILLING. FILL AND BACKFILL <br />SHALL BE DEPOSITED IN LAYERS NOT TO EXCEED 8 INCHES THICK, PROPERLY <br />MOISTENED TO APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY <br />ROLLED OR COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER AND <br />EXTENT AS TO PRODUCE A RELATIVE COMPACTION OF 90% OF MAXIMUM <br />POSSIBLE DENSITY AS DETERMINED BY ASTM D1557. HAND TAMPERS SHALL <br />WEIGH AT LEAST 50 POUNDS EACH AND SHALL HAVE A FACE AREA NOT IN <br />EXCESS OF 64 SQUARE INCHES. HAND TAMPERS MAY BE OPERATED EITHER <br />MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE LARGER POWER <br />DRIVEN COMPACTION EQUIPMENT CANNOT BE USED. FILL OVER 12" DEEP <br />SHALL COMPLY WITH A GEOTECHNICAL REPORT. <br />SHEARWALL EDGE NAILING <br />LTP4 PER SHEARWALL <br />TO BOTTOM PLATE <br />SCHEDULE <br />PRESSURE TREATED SILL PLATE <br />POST PER PLAN <br />SHEARWALL EDGE <br />ER SHEARWALL SCHEDULE. USE <br />NAILING TO SILL PLATE <br />2x6 W/ A.B. @ 48" O/C (MIN) <br />PB POST BASE <br />OR PER PLAN <br />4"(2) <br />#4 BARS @ <br />aII®Ii <br />�I `4 <br />TOP OF WALL <br />18" MIN-Ilhi�i <br />.© <br />#4 VERT @ 18" O/C (ALT HOOK <br />99 <br />6 MIN ® <br />10" b CONCRETE COLUMN <br />42" MAX <br />AS SHOWN) <br />. <br />® <br />#4 HORIZ. @ 18" O/ <br />(4) #4 VERTS EQUALLY <br />Ill�IF9II= <br />SPACED w/ #3 TIES @ 12" <br />5X <br />�II II <br />®/c, TYPICAL. HOOK <br />II II®1 <br />® I <br />VERTICAL BARS INTO <br />4" 0 PERFORATED PLASTIC <br />I <br />(2)#4 CONTINUOUS <br />18" MIN <br />FOOTING AS SHOWN <br />PIPE. CENTER IN ONE <br />oyy, <br />CUBIC FOOT OF FREE <br />FOOTING AND <br />DRAINING GRAVEL AND <br />REINFORCEMENT PER <br />DRAIN TO APPROVED <br />PLAN <br />OUTFALL. <br />JOISTS PERPENDICULAR <br />FOUNDATION TO <br />PONY WALK <br />ATYPICAL CONCRETE <br />PLINTH <br />l L- <br />APPLICABLE FOR ALL SHEARWALLS <br />SILL PLATE AND ANCHO LEDGER, JOISTS, �c <br />BOLTS PER SHE HANGER PER PLAN <br />SCHEDULE. (USE 2x6 P.T. <br />SILL PLATE W/ %" 0 EX. HOUSE FRAMING <br />J-BOLTS @ 48" 0/C MIN.) <br />SHEARWALL EDGE NAILING <br />TO SILL PLATE <br />4 <br />18" MIN <br />#4 HORIZ. @ 12" O/C <br />#4 VERT @ 18" O/C <br />4" 0 PERFORATED PLASTIC <br />PIPE. CENTER IN ONE <br />CUBIC FOOT OF FREE - <br />DRAINING GRAVEL Al <br />DRAIN TO APPROVED <br />OU TFALL. <br />BEAM PER PLAN <br />A35 CLIP @ 16" <br />o/c (MIN. 4) <br />2x SILL PLATE <br />SECURED TO <br />STEM PER PLAN <br />EX. RETAINING <br />PER L-1 <br />PLAN <br />(2) #4 HORZ. BARS <br />-EX. CONC. WALL <br />#4 DOWELS SECURED 8„ <br />TO EX. STEM WALL <br />w/ SET-3G (4" MIN. 12 <br />EMB.) <br />CONTINUOUS <br />NEW FOUNDATION <br />WALL PER PLAN <br />NAIL STRAP TO <br />STUDS PER <br />MANUFACTURER'S <br />SPECS. <br />HDG OR SS <br />MST60 STRAP <br />- CENTER ON <br />SILL PLATE <br />BOLT STRAP TO <br />CONCRETE w/ (3) Y2' <br />0 x 4" L WEDGE ALL <br />ANCHORS. PROVIDE <br />3" EDGE DISTANCE <br />TYPICAL. <br />3" -.-M IN' <br />e.. <br />•• EXISTING <br />CONCRETE <br />WALL <br />.d <br />5 H0LD0WN RETROFIT <br />EMBED ALL HORIZONTAL REBAR 4 <br />4099 <br />499 .d .I I <br />99 7 J1 <br />CONCRETE <br />FILLED HOLE <br />(1)#4 BAR EACH <br />WAY THROUGH POST <br />124" 0 I <br />3 EMBEDDED POST CONNECTION <br />POST PE OLD <br />PLAN (2 -2x PLAN <br />MIN) <br />PRESSURE <br />TREATED SILL <br />PLATE PER <br />SHEARWALL <br />SCHEDULE. <br />STEM WALL <br />AND <br />FOOTING <br />PER PLAN. <br />6 HOLDOWN DETAIL W/0 RIMJOIST <br />INTO EXISTING FOUNDATION AS SHOWN 2x12 PT HF#2 LEDGER (MIN) <br />AND EPDXY WITH SIMPSON 'SET'. w/ %" 0 TITEN HD BOLTS <br />STAGGERED @ 12" o/c. <br />EXISTING EMBED BOLTS 4" MINIMUM <br />FOUNDATION r2„ 'd INTO CONCRETE WALL. <br />(REBAR NOT i <br />SHOWN FOR �3//'::e0'.= <br />CLARITY) ________- <br />WALL STEM �� �I 1®---4" TYP <br />BEAM TO STEM CONN. NEW FNDN TO EXISTING FNDN <br />���� "a BONE 4 REBAR <br />JOIST & HANGERS PER PLAN <br />IN SHT <br />AR CONE <br />CONCRETE WALL PER (12" MIN. REBAR <br />PLAN 1/2" MIN. (LENGTH) <br />9 LEDGER TO CONCRETE WALL FROM CORNER <br />9 <br />CONNECTION 10 <br />� <br />O <br />� <br />® <br />N <br />N <br />Ln E <br />Q <br />N <br />cz o <br />U v <br />q) <br />OZ > <br />® <br />o �pN-Z <br />L <br />O >n <br />m ur <br />� <br />m <br />wn <br />Cn <br />®- <br />m <br />O <br />N <br />o <br />olLLJ <br />zLu <br />l <br />I <br />I <br />ol�l I I <br />aZ <br />®l <br />® D <br />:D LLJ <br />T_ � <br />Lu <br />00Lu <br />Drawn By: JIB <br />Checked By: CCC <br />Date: 1 2- 1 6-1 9 <br />5DA JOB NO. <br />(5707 <br />STRUCTURAL <br />DETAILS <br />®1.0 <br />O <br />® <br />N <br />N <br />Q N N O <br />Lund <br />� iQu <br />U <br />CZ > <br />m <br />® <br />0 'u N � <br />O ;�� <br />mWm <br />m <br />Ln <br />It <br />m <br />O <br />N <br />.. <br />�I <br />�I�III <br />oDO LL� <br />ICz <br />® Lu <br />< D <br />U_i <br />Lu <br />0 W <br />0 <br />Drawn By: JIB <br />Checked By: CCC <br />Date: 12-1 G-1 9 <br />5707 <br />STRUCTURAL <br />DETAILS <br />-3.0 <br />REINFORCING STEEL <br />9. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT. POUR JOINTS <br />GENERAL <br />1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 (fy = <br />SHALL BE LOCATED TO MINIMIZE EFFECTS OF SHRINKAGE AS WELL AS <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT <br />60 KSI) FOR BAR SIZES NO. 5 & LARGER, GRADE 40 (fy = 40 KSI) FOR NO. <br />PLACED AT POINTS OF LOW STRESS. MAXIMUM AREA OF POUR JOINTS IS 400 <br />DRAWINGS. <br />3 AND NO. 4 BARS. <br />SF. <br />2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE <br />2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE PLANS. <br />10. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR FORMED WORK <br />RESPONSIBLE FOR THE SAFETY OF THE BUILDING, THE CONTRACTOR SHALL <br />WHERE LAP OR SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED ON THE <br />SHALL BE AS FOLLOWS: <br />PROVIDE ADEQUATE SHORING, BRACING AND GUYS IN ACCORDANCE WITH ALL <br />CONSTRUCTION DOCUMENTS, LAPS AND/OR SPLICES SHALL BE 42 BAR DIA <br />EXPOSED TO EARTH OR WEATHER (#5 OR SMALLER): 19/2" <br />NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. ANY DEVIATION MUST BE <br />AND BE WELL STAGGERED. <br />EXPOSED TO EARTH OR WEATHER (6 OR LARGER): 2" <br />APPROVED PRIOR TO ERECTION. <br />*NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3" MINIMUM <br />3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED IN ACCORDANCE <br />COVERAGE <br />3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY <br />WITH ACI 315 SHALL BE REVIEWED BY THE ENGINEER AND AVAILABLE ON THE <br />DEVIATION MUST BE APPROVED BY OSHA PRIOR TO ERECTION. <br />JOB SITE PRIOR TO THE PLACING OF CONCRETE. <br />11. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN <br />STRUCTURAL CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED. <br />4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION <br />4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 AND A185 AND <br />PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT <br />SHALL BE 6x6 W2.1/W2.1 UNLESS OTHERWISE NOTED. LAP REINFORCEMENT 6" <br />12. LEAN CONCRETE SHALL BE 2 SACKS OF CEMENT PER CUBIC YARD OF <br />PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL <br />MINIMUM. <br />CONCRETE. <br />NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. <br />5. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE <br />13. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE WITH ACI 318. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK <br />SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED. SLAB ON GRADE <br />OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES <br />REINFORCEMENT SHALL BE PLACED AT MID -DEPTH OF SLAB AND SHALL BE <br />14. CONCRETE EXPOSED TO SULFATES, CONCRETE WITH LOW PERMEABILITY <br />SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND BE RESOLVED <br />HELD SECURELY IN PLACE WITH MECHANICAL DEVICES DURING PLACING OF <br />REQUIREMENTS, AND CONCRETE WITH CHLORIDE ION CONTENT REQUIRE <br />BEFORE PROCEEDING WITH THE WORK. <br />THE CONCRETE. <br />ADDITIONAL MIX DESIGN CONSIDERATIONS. IN THE EVENT OF THESE <br />REQUIREMENTS THE ENGINEER SHALL BE NOTIFIED BY THE CLIENT IN A <br />6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. <br />6. REINFORCEMENT SHALL PLACED CONTINUOUS AROUND CORNERS AND <br />WRITING AND DESIGN MIXES SHALL BE PROVIDED PER ACI 318. <br />WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR <br />ONSTRUCTION SHALL <br />INTERSECTIONS UNLESS SPECIFIED OTHERWISE. <br />CONCRETE <br />1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT <br />HARD ROCK TYPE (150 PCF) AGGREGATES SHALL CONFORM TO ASTM <br />C33 WITH PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05%. <br />CEMENT CONTENT <br />F'c (PSI) <br />LBS/CUBIC YARD <br />(MIN.) <br />SACKS PER CUBIC <br />YARD (MIN.) <br />NOTES <br />2500 <br />470 <br />5 <br />NOTE A <br />3500 <br />564 <br />6 <br />- <br />CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF C <br />BE USED SUBJECT TO REVIEW BY THE ENGINEER. <br />7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN <br />ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED OUT. <br />8. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS <br />2. CONCRETE COMPRESSIVE DESIGN STRENGTHS AT 28 DAYS (f'c) SHALL FOR SIZE AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES, <br />BE: NOTE 1: MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR PIPE SLEEVES, ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN <br />CONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL WORK <br />CONCRETE EXPOSURE & COMPRESSIVE DESIGN STRENGTHS <br />EXPOSURE <br />MIN. f'c <br />DESIGNATION <br />CONDITIONS <br />CLASS <br />(psi) <br />HEATED: SLABS, BEAMS, <br />INTERIOR GONG. & <br />GIRDERS, COLUMNS, PIERS, AND <br />FOOTINGS <br />FD <br />2500 <br />BURRED FOOTINGS <br />FOUNDATION WALLS, UN -HEATED: <br />SLABS, BEAMS, GIRDERS, <br />UNSATURATED <br />F1 <br />3500 <br />COLUMNS, PIERS, PILE CAPS, <br />EXTERIOR GONG. <br />SHEAR WALLS <br />LESS. NO MORE THAN A 1" PLUS TOLERANCE SHALL BE ALLOWED. <br />NOTE 2: AIR ENTRAINMENT IS REQUIRED FOR ALL CONCRETE EXPOSED TO 9. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS <br />WEATHER. FOR 3/4" AGGREGATE AN ENTRAINMENT OF 6% IS REQ'D. FOR Y2" FOR HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC. ALL <br />SUSPENDED MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. <br />AGGREGATE AN AIR ENTRAINMENT OF 7% IS REQ'D. <br />10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING <br />NOTE 3: POZZOLANS ARE NOT PERMITTED IN THE MIX DESIGN UNLESS CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT <br />APPROVED BY THE ENGINEER. GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE <br />DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEER SO THAT THE <br />A) WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER SECTION 1704.4 OF PROPER REVISIONS MAY BE MADE. MODIFICATION TO DETAILS OF <br />THE I.B.C., CONCRETE SHALL HAVE A MINIMUM CEMENT CONTENT OF 5 SACKS CONSTRUCTION SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF <br />PER CUBIC YARD OF CONCRETE. THE ENGINEER. <br />3. ALL CONCRETE WITH A DESIGNATED COMPRESSIVE STRENGTH <br />EXCEEDING 2500 PSI SHALL REQUIRE SPECIAL INSPECTION BY AN B) FOR STRENGTHS ABOVE 4000 PSI, PROPORTIONS SHALL BE ESTABLISHED 11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF <br />INSPECTOR APPROVED BY THE BUILDING DEPARTMENT AND THE BY THE METHODS SPECIFIED ACI 318. THE STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL <br />ENGINEER. EXCEPTION: NO INSPECTION IS REQUIRED WHERE CONCRETE CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF <br />EXCEEDING 2500 PSI IS DESIGNATED FOR WEATHERING PURPOSES ONLY. C) DESIGN MIX (OTHER THAN AS SPECIFIED IN THIS TABLE) SHALL BE MEMBERS, ELEVATIONS, DIMENSIONS AND LOCATIONS OF ALL OPENINGS, ETC. <br />SUBMITTED TO THE BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST USE. <br />4. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, CSA NORMAL. <br />5. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. <br />6. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 301, <br />7. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A <br />MINIMUM OF FIVE (5) DAYS AFTER PLACEMENT. ALTERNATE METHODS <br />WILL BE APPROVED IF SATISFACTORY PERFORMANCE CAN BE ASSURED. <br />8. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL CASES. ALL <br />CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND ALL <br />LAITANCE SHALL BE REMOVED. ALL VERTICAL JOINTS SHALL BE <br />THOROUGHLY WETTED AND SLUSHED WITH A COAT OF NEAT CEMENT <br />IMMEDIATELY BEFORE PLACING NEW CONCRETE. <br />9. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT. POUR <br />JOINTS SHALL BE LOCATED TO MINIMIZE EFFECTS OF SHRINKAGE AS <br />WELL AS PLACED AT POINTS OF LOW STRESS. MAXIMUM AREA OF POUR <br />JOINTS IS 400 SF. <br />SHEARWALL SCHEDULE (CDX) <br />MARK <br />SHEATHING <br />EDGE NAILING <br />FIELD NAILING <br />SILL PLATE & <br />CONN. @ END <br />BOTTOM/TOP PLATE <br />CONN. <br />3/s" CDX ONE <br />8d @ 6" O/C <br />8d @ 12" O/C <br />s <br />O/C W/ 2x 8v <br />SILL <br />LC <br />x ® W/ BOT M <br />FACE <br />PLATE <br />PLATE <br />A%" <br />CDX ONE <br />8d @ 4" O/C <br />8d @ 12" O/C <br />V 0 A.B. @ 36" <br />O/C W/ 2x SILL <br />LTP4 @ 14" O/C <br />W/ 2x BOTTOM <br />FACE <br />PLATE <br />PLATE <br />t�/32" CDX ONE <br />10d @ 4" O/C <br />10d @ 12 O/C <br />V 0 A.B. @ 30" <br />O/C W/ 3x SILL <br />LTP4 @ 12" O/C <br />W/ 2x BOTTOM <br />FACE <br />PLATE <br />PLATE <br />1%2" CDX ONE/s" <br />10d @ 3" 0/C <br />10d @ 12" O/C <br />A.D. ®24" <br />O/C W/ 3x SILL <br />LTP4 @ 9" O/C W/ <br />FACE <br />PLATE <br />3x BOTTOM PLATE <br />9HLANWALL INU I L:--)- <br />1. ALL STUDS, BLOCKING, TOP AND BOTTOM PLATES SHALL BE HEM -FIR NO. 2 UNLESS NOTED <br />OTHERWISE ON PLANS. ALL SHEATHING EDGES MUST BE BACKED WITH 2x OR WIDER FRAMING <br />(SEE NOTE #3). <br />2. SHEATHING MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY. ALL SHEARWALL <br />SHEATHING MUST EXTEND TO THE OUTISDE EDGE OF ALL HOLDOWN POSTS AND CORNERS, AND <br />TO THE INSIDE EDGE OF FRAMING AROUND OPENINGS. <br />3. WHERE SHEATHING NAILING IS SHEARWALL SW-2 AND GREATER, ALL FRAMING MEMBERS <br />RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3-INCH <br />NOMINAL MEMBER. ADDITIONALLY, WHERE SHEARWALLS ARE SHEATHED ON BOTH FACES, ALL <br />STUDS •AND PLATES RECEIVING EDGE NAILING FROM BOTH FACES MUST BE .A SINGLE 3-INCH <br />NOMINAL MEMBER OR PANEL JOINTS MUST BE OFFSET. (2)2x MAY BE SUBSTITUTED FOR A <br />SINGLE 3x MEMBER PROVIDED THE STUDS ARE STITCH NAILED TOGETHER w/ 10d NAILS <br />STAGGERED @ 6" o/c FROM EACH SIDE. <br />4. SHEARWALL NAILING CRITERIA IS BASED ON TABLE 4.3A OF THE 2015 AMERICAN WOOD <br />COUNCIL SDPWS (SPECIAL DESIGN PROVISIONS FOR WIND & SEISMIC). VALUES ARE BASED ON <br />OSB SHEATHING w/ HEM -FIR NO. 2 FRAMING AND COMMON NAILS. <br />5. HOLDOWNS AND OTHER CONNECTIONS MAY BE REQUIRED AT THE ENDS OF MANY SHEARWALLS. <br />SIZES AND LOCATIONS OF THESE CONNECTORS ARE INDICATED ON THE PLANS. REFER TO THE <br />APPROPRIATE DETAILS AND/OR HOLDOWN SCHEDULE FOR ADDITIONAL INFORMATION REGARDING <br />ANCHOR BOLTS, EMBEDMENT LENGTH, ETC. WHERE (2) 2x's ARE USED AS A HOLDOWN POST, <br />SHEARWALL EDGE NAILING MUST BE STAGGERED INTO EACH MEMBER OF THE POST. <br />6. ANCHOR BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR GROUTED CMU, <br />AND SHALL BE PLACED TO PROVIDE A MINIMUM OF 2" COVER. PROVIDE 3" COVER FOR <br />CONCRETE CAST AGAINST SOIL. <br />7. ALL MACHINE BOLTS SHALL BE ASTM A307 OR BETTER. HILTI KWIK BOLTS/SIMPSON TITEN HD <br />OLTS OF THE SAME DIAMETER AS SHOWN IN THE SHEARWALL SCHEDULE MAY BE SUBSTITUTED <br />OR ANCHOR BOLTS INTO EXISTING CONCRETE. BOLTS SHALL BE EMBEDDED A MINIMUM OF 33/' <br />NTO EXISTING CONCRETE. <br />ALL NAILS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD (EXCEPT FOR <br />ORITE TREATED WOOD) MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL TO RESIST <br />CORROSION. <br />9. WIRE STAPLES MAY BE SUBSTITUTED FOR NAILS IN SHEAR PANELS. <br />0, NAILS MUST BE STAGGERED WHEN SPACED AT 2" O/C. <br />FOR DOUBLE SIDED <br />HOEDOWN POST. SEE LENGTH OF SHEARWALLS, THE SHEATHING <br />ON EACH FACE MUST EXTEND <br />HOLDOWN SCHEDULE OR SHEARWALL <br />PLAN FOR MINIMUM CONTINUOUS BETWEEN <br />REQUIREMENTS HOEDOWN POSTS AS SHOWN. <br />LOCATION OF <br />HOLDOWN TO BE <br />INSTALLED <br />LATERAL MARKING <br />LEGEND <br />TYPE OF HOLDOWN TO BE <br />INSTALLED <br />SHEARWALL DESIGNATION - SEE SHEARWALL SCHEDULE <br />FOR FRAMING, NAILING AND ANCHORAGE REQUIREMENTS <br />42 DIA. <br />f <br />�11 . <br />- m�e®r�aaoa_ve e�-a <br />° -4-2 Q,IA.-I-42 DIA. 2' 0'I A. <br />2-0 2'-0" MIN. <br />MIN. <br />CORNER REINFORCING TYPICAL - <br />HOLDOWN SCHEDULE <br />*FOR HOLDOWNS INSTALLED IN NEW FOUNDATIONS <br />THRU BOLTS <br />EMBEDMENT/ <br />MINIMUM <br />MODEL <br />ANCHOR <br />OR <br />STRAP <br />EDGE <br />le <br />de <br />BOLT <br />NAILS/SCREWS <br />LENGTH <br />DIST. <br />STHD8 <br />- <br />N/A <br />(24) 10d COMMON <br />8" EMBED <br />1Y�' <br />NA <br />NA <br />STHD10 <br />N/A <br />(28) 16d COMMON <br />10" EMBED <br />1Y2' <br />NA <br />NA <br />HDU4-SDS2.5 <br />SSTB16 <br />(10) SDSx2" <br />12" EMBED <br />13/4 <br />NA <br />NA <br />SCREWS <br />HDU5-SDS2.5 <br />SSTB20 <br />(14SCREWS2 <br />20„ EMBED <br />13/4 <br />NA <br />NA <br />HDU8-SDS2.5 <br />SSTB28 <br />(20) SDSY4x3 <br />SCREWS <br />24%" EMBED <br />13/4" <br />NA <br />NA <br />CS14 <br />N/A - <br />(IN )SINGLE OM <br />34" EAR <br />ER ®N <br />NA <br />NA <br />STUDN <br />SPAN <br />RIMTJ01 <br />MST60 <br />N/A <br />(46) 10d COMMON <br />60 <br />CENTER ON <br />NA <br />NA <br />IN DOUBLE STUD <br />RIM JOIST <br />MSTC78 <br />N/A <br />(76) 10d COMMON <br />773/4" <br />CENTER ON <br />NA <br />NA <br />IN DOUBLE STUD <br />_ - <br />RIM JOIST <br />- <br />HOLDOWN NOTES <br />1. ALL -THREAD BOLTS SHALL CONFORM TO ASTM A307. <br />2. MINIMUM CONCRETE COMPRESSIVE STRENGTH f'c = 2500 PSI. MINIMUM WALL THICKNESS IS <br />8'9 <br />3. ALL HOLDOWNS REQUIRE A (2) 2x POST UNLESS NOTED OTHERWISE. HDU11 AND HHDQ14 <br />REQUIRE A 6x6 D F# 2 MINIMUM POST SIZE, U.N.O. WHERE HOLDOWNS ARE INSTALLED INTO <br />THE WIDE FACE OF THE STUD, THE STUDS MUST BE STITCH NAILED TOGETHER W/ 16d <br />SINKERS STAGGERED @ 4" 0/C. <br />4. MINIMUM EDGE DISTANCE IS FOR FORMED CONCRETE EXPOSED TO WEATHER OR SOIL. FOR <br />CONCRETE CAST AGAINST SOIL PROVIDE 3" CLEAR TO ANCHOR BOLT. <br />5. NAILS/SCREWS TO HOLDOWN POST SHALL BE PER MANUFACTURER'S SPECIFICATIONS. <br />6. WHEN FIELD CONDITION BECOME LESS THAN MINIMUM SHOWN, CONTACT ENGINEER PRIOR TO <br />PROCEEDING. <br />7. ALL HOLDOWN BOLTS MUST BE RE -TIGHTENED JUST PRIOR TO ENCLOSING SECOND SIDE OF <br />WALL. <br />DOUBLE STUD <br />OR PER PLAN <br />--STRAP PER PLAN - <br />CENTER BETWEEN <br />FLOORS. <br />L CLEAR SPA <br />NO NAILS <br />REQUIRED <br />, FLOOR TO FLOOR STRAP <br />CORNER BAR <br />SAME SIZE & <br />SPACING AS <br />HORIZ. WALL <br />REINF. <br />CJ TY; <br />T <br />REVIEVVED FOR PERMIT <br />u <br />� <br />O <br />0 <br />® <br />N <br />n <br />N <br />�( <br />�QN E <br />m 0 O <br />Udn_. v <br />CZ <br />O p73 <br />o <br />> G-) <br />mwm <br />m <br />Ln <br />® <br />N <br />0I <br />�I <br />I <br />6I <br />I <br />I <br />az <br />ICI <br />.IE) <br />Lu „ <br />LLJ <br />7 <br />1 <br />00� <br />Drawn By: JIB <br />Checked By: CCC <br />Date: 1 2- 1 G- 19 <br />5DA JOB NO. <br />(5707 <br />STRUCTURAL <br />DETAILS <br />S® ® 0 <br />0 <br />U <br />N <br />N <br />��N Ie <br />Q <br />18 <br />��� <br />U-� <br />v <br />CL/m <br />0 u C\j� <br />O > N <br />J <br />JO <br />m <br />N <br />m <br />Lu <br />C�Ln <br />I�I <br />I <br />I <br />27 <br />Es U-i <br />l�J <br />� LL1 <br />5 Lu <br />Drawn By:.J1B <br />Checked By: CCC <br />Date: 1 2- 1 G-1 9 <br />5DA JOB NO. <br />707 <br />STRUCTURAL <br />DETAILS <br />S-4.0 <br />