Laserfiche WebLink
CONDENSING UNIT SCHEDULE <br />OUTDOOR CONDENSING UNIT <br />EQUIP. <br />TAG <br />AREA SERVED <br />MANUFACTURER / MODEL <br />NUMBER <br />NOM. <br />TON <br />MBH <br />SEER <br />WT. <br />LBS <br />EL�C. REQ. <br />NOSE <br />DBA <br />REMARKS <br />TOTAL <br />TOTAL <br />SENS. <br />MCA <br />VOLTS <br />PH. <br />CU-1 <br />WEST OFFICES <br />TRANS / 4TTR6030J1 <br />2.5 <br />28.6 <br />20.5 <br />15.5 <br />200 <br />17 <br />208 <br />1 <br />73 <br />1, 2, 3 <br />CU-2 <br />SOUTH OFFICES <br />TRANE / 4TTR6018J1 <br />1.5 <br />17.8 <br />12.7 <br />16.5 <br />170 <br />12 <br />208 <br />1 <br />73 <br />1, 2, 3 <br />CU-3 <br />CLASSROOM 110 <br />TRANE / 4TTR6018J1 <br />1.5 <br />17.8 <br />12.7 <br />16.5 <br />170 <br />12 <br />208 <br />1 <br />73 <br />1, 2, 3 <br />CU-4 <br />CONFERENCE 113 <br />TRANE / 4TTR6018J1 <br />1.5 <br />17.8 <br />12.7 <br />16.5 <br />170 <br />12 <br />208 <br />1 <br />73 <br />1, 2, 3 <br />CU-5 <br />COMMUNITY ROOM 105 <br />TRANE / 4TTR6042J1 <br />3.5 <br />38.7 <br />26.1 <br />15.50 <br />265 <br />21 <br />208 <br />1 <br />72 <br />1, 2, 3 <br />CU-6 <br />EAST OFFICES <br />TRANE / 4TTR6018J1 <br />1.5 <br />17.8 <br />12.7 <br />16.5 <br />170 <br />12 <br />208 <br />1 <br />73 <br />1, 2, 3 <br />NOTES: 1. PROVIDE WITH T.O.C., LOW AMBIENT KIT, MOUNTING BASE <br />2. OGLING CAPACITY RATINGSATARICONDITI S OF 95FOUTD00R 80/67 ENTERINGING COILCONDITION, HEAT P HEATING CAPACITY AT47 F OUTDOOR TDOOR <br />3. PROVIDE REFRIGERANT PIPING FROM OUTDOOR UNIT TO INDOOR COIL. <br />EQUIP. <br />TAG <br />CC-1 <br />AREA SERVED <br />WEST OFFICES <br />MANUFACTURER/ MODEL NUMBER <br />TRANE / 4TXCB031BC3 <br />AIRFLOW <br />CFM <br />1000 <br />APt�. IN WC <br />0.3 <br />CONFIGURATION <br />HORIZONTAL <br />WT. LBS <br />45 <br />REMARKS <br />1, 2, 3, 4, 5 <br />CC-2 <br />CC-3 <br />SOUTH OFFICES <br />CLASSROOM 110 <br />TRANE / 4TXCB025BC3 <br />TRANE / 4TXCB025BC3 <br />600 <br />600 <br />0.3 <br />0.3 <br />HORIZONTAL <br />HORIZONTAL <br />45 <br />45 <br />1, 2, 3, 4, 5 <br />1, 2, 3, 4, 5 <br />CC-4 <br />CONFERENCE 113 <br />TRANE / 4TXCB025BC3 <br />600 <br />0.3 <br />HORIZONTAL <br />45 <br />1, 2, 3, 4, 5 <br />CC-5 <br />COMMUNITY ROOM 105 <br />TRANE / 4TXCB006DS3 <br />1400 <br />0.3 <br />HORIZONTAL <br />55 <br />1, 2, 3, 4, 5 <br />CC-6 <br />EAST OFFICES <br />TRANE / 4TXCB025BC3 <br />600 <br />0.3 <br />HORIZONTAL <br />45 <br />1, 2, 3, 4, 5 <br />NOTES: 1. PROVIDE REFRIGERANT PIPING FROM OUTDOOR UNIT TO INDOOR COIL. <br />2. PIPE CONDENSATE TO DRAIN. PROVIDE WITH CONDENSATE PUMP LITTLE GIANT VCMA-15, 115V/1 PH, 1/50 HP. <br />3. COOLING CAPACITY RATINGS AT ARI CONDITIONS OF 95F OUTDOOR, 80/67 ENTERING COIL CONDITION, HEAT PUMP HEATING CAPACITY AT 47-F OUTDOOR <br />4. PROVIDE WITH EZTRAP MODEL EZT--225 CONDENSATE OVERFLOW SWITCH TO SHUT-OFF UNIT WITH MOISTURE DETECTION <br />GAS FURNACE SCHEDULE <br />EQUIPMENT <br />TAG <br />F-1 <br />MANUFACTURER/ MODEL <br />NUMBER <br />TRANE / TUH2B060A9V3 <br />AREA SERVED <br />WEST OFFICES <br />HEATING <br />INPUT <br />MBH OUTPUT MBH AFUE%o <br />39 / 60 37.7 / 58 96.7 <br />TOTAL <br />CFM <br />9Q0 <br />OSA <br />CFM <br />115 <br />E.S.P. <br />IN W.C. <br />0.7 <br />FAN MOTOR <br />CONFIGURATION <br />HORIZONTAL <br />WT. <br />LBS <br />175 <br />REMARKS <br />1, 2, 3, 4, 5, 6 <br />H.P. <br />1/2 <br />MOP <br />15 <br />VOLTS <br />115 <br />PH. <br />1 <br />- <br />DRIVE <br />DIRECT <br />F2 <br />TRANE / TUH2B060A9V3 <br />SOUTH OFFICES <br />39 / 60 <br />37.7 / 58 <br />96.7 <br />600 <br />45 <br />0.7 <br />1/2 <br />15 <br />115 <br />1 <br />DIRECT <br />HORIZONTAL <br />175 <br />1, 2, 3, 4, 5, 6 <br />F 3 <br />TRANE / TUH2B060A9V3 <br />CLASSROOM 110 <br />39 / 60 <br />37.7 / 58 <br />96.7 <br />600 <br />200 <br />0.7 <br />1/2 <br />15 <br />115 <br />1 <br />DIRECT <br />HORIZONTAL <br />175 <br />1, 2, 3, 4, 5,6 <br />F-4 <br />TRANE / TUH2B060A9V3 <br />CONFERENCE 113 <br />39 / 60 <br />37.7 / 58 <br />96.7 <br />600 <br />100 <br />0.7 <br />1/2 <br />15 <br />115 <br />1 <br />DIRECT <br />HORIZONTAL <br />175 <br />1, 2, 3, 4, 5, 6 <br />F-5 <br />TRANS / TUH2B080A9V4 <br />COMMUNITY ROOM 105 <br />52 / 80 <br />49.5 / 76 <br />95 <br />1400 <br />250 <br />0.7 <br />1/2 <br />15 <br />115 <br />1 <br />DIRECT <br />HORIZONTAL <br />185 <br />1, 2, 3, 4, 5, 6 <br />F-6 <br />TRANE / TUH2B06QA9V3 <br />EAST OFFICES <br />39 / 60 <br />37.7 / 58 <br />96.7 <br />600 <br />40 <br />0.7 <br />1/2 <br />15 <br />115 <br />1 <br />DIRECT <br />HORIZONTAL <br />175 <br />1, 2, 3, 4, 5, 6 <br />NOTES: 1. MATCH TO CORRESPONDING CU/CC <br />2. ALL CONNECTIONS SHALL BE FLEXIBLE TO UNIT SUPPLY AND RETURN. <br />3. PROVIDE CONDENSATE DRAIN AND TRAP AS REQUIRED. PROVIDE WITH CONDENSATE NEUTRALIZER KIT. <br />4. PROVIDE CONCENTRIC CA/FLUE TERMINATION AT ROOF. <br />5. PROVIDE WITH 100% ECONOMIZER AND CONTROLS. PROVIDE WITH ECONOMIZER FAULT DETECTION PER WSEC. <br />6. PROVIDE WITH HONEYWELL COMMERCIAL, VISION PRO 7-DAY PROGRAMABLE THERMOSTAT. <br />EXHAUST <br />FAN SCHEDULE <br />EQUIP. <br />E.S.P. <br />FAN MOTOR <br />NOISE <br />TAG <br />MFG' / MODEL NUMBER <br />AREA SERVED <br />CFM <br />INCHES <br />DRIVE <br />CONFIGURATION <br />REMARKS <br />W.G. <br />HP <br />VOLTS <br />PH. <br />SONES <br />EF-1 <br />GREENHECK / SP-A200 <br />MEN'S 109 <br />75 <br />0.5 <br />34.5 W <br />115 <br />1 <br />1 <br />2.5 <br />DIRECT <br />CEILING <br />112, 3, 4, 5 <br />EF2 <br />GREENHECK i SP-1390 <br />WOMEN'S 108 <br />125 <br />0.5 <br />1 20.3 W <br />115 <br />1 <br />2 <br />DIRECT <br />CEILING <br />1, 2, 3, 4, 5 <br />E -3 <br />eNWCAE H S- 0 <br />1 <br />0 <br />5 <br />.5 <br />2.5 <br />D EC <br />C I <br />3, 5 <br />EF-4 <br />GREENHECK d SP-A710-VG <br />STORAGE / EL EC 112 <br />300 <br />0.5 <br />285 W <br />115 <br />1 <br />4 <br />[DIRECT <br />CEILING <br />3, 4, 5, 6 <br />NOTES: 1, PROVIDE FAN WITH SPEED CONTROL. MOUNT ON FAN HOUSING. <br />2. FAN TO RUN CONTINUOUSLY DURING OCCUPIED HOURS, PROVIDE WITH TIME CLOCK. <br />3. MOUNT FANS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND CLEARANCES. <br />4. PROVIDE WITH MOTORIZED DAMPER TO CLOSE WHEN FAN NOT IN USE. <br />5. DUCT CONNECTS TO FAN WITH APPROVED FLEXIBLE CONNECTORS. <br />6. PROVIDE FAN WITH LINE VOLTAGE REVERSE ACTING THERMOSTAT. <br />ROOF <br />HOOD <br />SCHEDULE. <br />AIR <br />MIN. <br />THROAT <br />EQUIP. <br />MFG' / MODEL NUMBER <br />TYPE <br />SERVICE <br />TYPE <br />FLOW <br />FREE AREA <br />DIMENSIONS <br />WEIGHT <br />TAG <br />CFM <br />(SQ. FT.) <br />W" x L" <br />LBS. <br />REMARKS <br />H-1 <br />GREENHECK / FGR <br />ROOF <br />OSA <br />INTAKE <br />2,100 <br />3.3 <br />18 x 26 <br />80 <br />1, 2, 3 <br />H2 <br />GREENHECK / GRSR <br />ROOF <br />OSA <br />INTAKE <br />600 <br />1.0 <br />12 x12 <br />50 <br />1, 2, 3 <br />H-3 <br />GREENHECK / FGR <br />ROOF <br />OSA <br />INTAKE <br />2,000 <br />3.3 <br />18 x 26 <br />80 <br />1, 2, 3 <br />H-4 <br />GREENHECK / GRSR <br />ROOF <br />EXHAUST <br />RELIEF <br />45 <br />0.4 <br />8"o <br />20 <br />1, 2, 3 <br />H-5 <br />GREENHECK / GRSR <br />ROOF <br />EXHAUST <br />EXHAUST <br />100 <br />0.4 <br />8"o <br />20 <br />1, 2, 3 <br />H-6 <br />GREENHECK / FGR <br />ROOF <br />RELIEF <br />RELIEF <br />2,100 <br />3.3 <br />18 x 26 <br />80 <br />1, 2, 3, 4 <br />- <br />C 1F <br />F <br />E FA <br />6 AF_ <br />1 <br />0en <br />2 <br />H-8 <br />GREENHECK / GRSR <br />ROOF <br />EXHAUST <br />EXHAUST <br />300 <br />0.4 <br />10"o <br />30 <br />1, 2, 3 <br />1 <br />NOTES: 1. PROVIDE WITH GREENHECK GPI-G12 ROOF CURES <br />2. PAINT TO MATCH ROOF SURFACE. COORDINATE COLOR WITH ARCHITECT. <br />3. PROVIDE WITH MOTORIZED DAMPER AND DAMPER TRAY. <br />4. PROVIDE WITH BACKDRAFT DAMPER. <br />ELECTRIC HEATER SCHEDULE <br />EQUIP. <br />CONTROL <br />ELECTRICAL <br />TAG <br />LOCATION <br />MFG/MODEL # <br />WATTS <br />ORIENTATION <br />OPTION <br />V/PH <br />REMARKS <br />EH-1 <br />STORAGE 112 <br />KING / PAW <br />500 <br />WALL MOUNT <br />INTEGRAL <br />120V / 1 <br />1 <br />EH-2 <br />MECHANICAL 111 <br />KING / PAW <br />500 <br />WALL MOUNT <br />INTEGRAL <br />120V / 1 <br />1 <br />NOTES: 1. COORDINATE LOCATION OF UNIT WITH ARCHITECTURAL FEATURES AND ALL OTHER TRADES <br />L`, <br />PLUMBING FIXTURE SCHEDULE <br />LOCAL CONFECTIONS <br />TAG <br />DESCRIPTION <br />W V HW CW <br />CP1 <br />CIRCULATION PUMP - GRUNDFOS HOT WATER CIRCULATING PUMP UP 15-35SFC, 3 SPEED, 6GPM @ 8FT HEAD, <br />-- 3/4" -® <br />115V/lA/110W AND 0.15HP, PROVIDE WITH TIMECLOCK FOR CONTROL. <br />ELECTRIC WATER COOLER WITH BOTTLE FILLER (ADA, SINGLE) - ELKAY LZSBWSVRK, BARRIER FREE, SELF CONTAINED, <br />SINGLE WALL HUNG, ELECTRIC REFRIGERATED WATER COOLER, 8.0 GPH AT 50°F WATER TEMP. WITH 80°F INLET <br />DF1 <br />WATER, FRONT/SIDE PUSH PADS, VANDAL RESISTANT BUBBLER, PROVIDE COLD WATER STOP VALVE AND P-TRAP, <br />1-1/2" EA 1-1/2" EA - 1/2" EA <br />BOTTLE FILLER STATION, ELECTRONIC SENSOR WITH TOUCHLESS ACTIVATION, 20 SEC AUTO SHUTOFF, VISUAL USER <br />INTERFACE, 115V, 5.0 FLA, 370 W. <br />DVV1 <br />UNDERCOUNTER DISHWASHER - OFCI, ROUGH -IN AND CONNECT DOUBLE HW STOP VALVE AT ADJACENT SINK, <br />-- -- 1>2" -- <br />PROVIDE AIR GAP FITTING AT SINK. <br />FD1 <br />FLOOR DRAIN - (SLAB ON GRADE) - J.R. SMITH 2O05Y, 5" NB TOP, Cl BODY, PROVIDE WITH TRAP PRIMER LINE. <br />2" 2" <br />HB1 <br />HOSE BIBB - WOODFORD 68, NON -FREEZE, ASSE 1052 DOUBLE CHECK BACKFLOW PREVENTER, LOCKING COVER, <br />-- -- -- 3/4" <br />SELF DRAINING, TEE KEY OPERATION. <br />LAVATORY (ADA) - WALL HUNG, AMERICAN STANDARD 0355.012, 20X18 NOM., VITREOUS CHINA, DELTA 501 LF-WF <br />L1 <br />FAUCET, 1/2 GPM FLOW, SINGLE HANDLE, SCREWDRIVER STOPS & SUPPLIES, 1-1/4" CP, 17 GA CHROME PLATED <br />2" 1-1/2" 1/2" 1/2" <br />P-TRAP, PLUMBEREX TRAP GEAR SERIES P-TRAP/ H&C COVERS, PROVIDE WITH LEONARD 270 THERMOSTATIC MIXING <br />VALVE. <br />JANITOR SINK - FLOOR MOUNTED FIAT MSB-2424 WITH RIM GUARD & STRAINER, 5' HOSE & BRACKET, CHICAGO #897 <br />MS1 <br />FAUCET WITH VACUUM BREAKER, WALL BRACE, WALL GUARD, SCREWDRIVER STOPS, PAIL HOOK & HOSE END, <br />3" 2" 1/2" 1/2" <br />PROVIDE LEONARD 270 THERMOSTATIC MIXING VALVE. <br />R1 <br />REFRIGERATOR WITH ICE MAKER - OWNER FURNISHED, ROUGH -IN AND CONNECT CW. ROUTE WATER LINE FROM STOP <br />„ <br />VALVE AT SINK TO ICEMAKER INSIDE CABINET. <br />-- -- - 1/2 <br />SINK (SINGLE COMPARTMENT) - JUST MODEL SL-ADA-1921-A-GR, 19"X21" NOM. MAX. 6.5" DEEP, CENTER DRAIN, ELKAY <br />S1 <br />MODEL LK5000, SINGLE HANDLE FAUCET, PULL-OUT SPRAY, 9.5" SWINGSPOUT, 1.5 GPM, GRID DRAIN, SCREWDRIVER <br />2" 1-1/2" 1/2" 1/2" <br />STOPS & SUPPLIES, 17 GA CHROME PLATED P-TRAP, PLUMBEREX HANDY -SHIELD MAXX SERIES P-TRAP AND H&C <br />SUPPLY COVERS OR EQUAL, <br />SINK (DOUBLE COMPARTMENT) - JUST MODEL DL-ADA-1933-A-GR, 19"X33" NOM. MAX. 6.5" DEEP, CENTER DRAIN, ELKAY <br />S2 <br />MODEL LK5000, SINGLE HANDLE FAUCET, PULL-OUT SPRAY, 9.5" SWINGSPOUT, 1.5 GPM, GRID DRAIN, SCREWDRIVER <br />2" 1-1/2" 1/2" 1/2" <br />STOPS & SUPPLIES, 17 GA CHROME PLATED P-TRAP, PLUMBEREX HANDY -SHIELD MAXX SERIES P-TRAP AND H&C <br />SUPPLY COVERS OR EQUAL, PROVIDE IN-SINK-ERATOR BADGER 5XP GARBAGE DISPOSER, 3/4HP 120V 8.1A. <br />WATER CLOSET - (FLOOR MOUNT FLUSH TANK / GRAVITY FLUSH) AMERICAN STANDARD 2002.014, ADA COMPLIANT, 1.6 <br />WC1 <br />GPF, EVERCLEAN SURFACE, VITREOUS CHINA, CHAMPION 4 FLUSHING SYSTEM, OPEN FRONT SEAT, SCREWDRIVER <br />3" 2" -- 1/2" <br />STOP & SUPPLY, NO -SEEP WAX RING W/SLEEVE, CLOSET BOLTS, NUTS & WASHERS, LOCATE FLUSH HANDLE AT WIDE <br />SIDE OF APPROACH. <br />WATER HEATER (GAS) - A.O. SMITH MODELGPDT 50,45 MSH INPUT, 0.70 ENERGY FACTOR, 50 GALLON TANK, 50.3 OPH <br />WH1 <br />RECOVERY @ 90F TEMPERATURE RISE, (2)2"0 COMBUSTION / INTAKE VENTS TO EXTERIOR, PROVIDE PRESSURE AND <br />- 3/4" 3/4" <br />TEMPERATURE RELIEF, PROVIDE SEISMIC STRAPS, 120V. <br />NOTES: <br />I. MIN. OSA CFM REQUIRED = (# PEOPLE XCFM/PERSON)+ (AREA XCFM/SQ.FT.) <br />l <br />h <br />m <br />,0Y_ i <br />o <br />fd U <br />to <br />U <br />CO <br />CO- vco <br />co <br />M <br />co <br />4 <br />5 <br />f ; <br />c <br />z, <br />x7 <br />Job No: 1519.02 Date: 2017 05 12 <br />File No: Grandview Clubhouse <br />Drawn By: GLK <br />Cheoked By: KLY <br />Issued for: BID SET <br />FLAN REVISIONS 08/23/17 <br />I� • <br />=x g "t fi <br />51 o, <br />�' : <br />