A PORTION OF SECTION 17, T 29 N, R 5 E, WM <br />GENERAL CONSTRUCTION NOTES <br />1. ALL WORK AND MATERIAL SHALL CONFORM TO THE CITY OF EVERETT <br />STANDARDS AND STANDARD SPECIFICATIONS OF WDSOT/APWA. <br />2. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM <br />AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID <br />DAMAGE TO ANY ADDITIONAL UTILITIES SHOWN. IF CONFLICTS WITH EXISTING <br />UTILITIES ARISE DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE <br />DISTRICT AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE <br />ENGINEER PRIOR TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE <br />PROJECT. <br />3. NO PART OF THE DRAINAGE SYSTEM SHALL BE COVERED, CONCEALED OR PUT <br />INTO USE UNTIL IT HAS BEEN INSPECTED, TESTED AND ACCEPTED. <br />4. ALL STORM SYSTEMS WITHIN THE PUBLIC RIGHT—OF—WAY OR IN EASEMENTS <br />MUST BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO STARTING <br />CONSTRUCTION. <br />5. ALL CATCH BASIN GRATES MUST BE STENCILED OR STAMPED "DUMP NO <br />WASTE, DRAINS TO STREAM, LAKE, RIVER, PUGET SOUND OR WETLAND". <br />CHOOSE APPROPRIATE FEATURE FOR THE PROJECT. <br />6. CONTRACTOR TO PROVIDE STORM WATER BYPASS AS REQUIRED FOR <br />DEWATERING DURING CONSTRUCTION OF NEW SYSTEMS. <br />7. CONTRACTOR TO OVEREXCAVATE AS NECESSARY TO PROVIDE STABLE <br />FOUNDATION FOR STRUCTURES. <br />8. WHERE TRENCH EXCAVATION EQUALS OR EXCEEDS A DEPTH OF 4 FEET, THE <br />CONTRACTOR SHALL PROVIDE, CONSTRUCT, MAINTAIN AND REMOVE , AS <br />REQUIRED, SAFETY SYSTEMS THAT MEET THE REQUIREMENTS OF THE <br />WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, RCW 49.17, INCLUDING <br />WAC 296-155. <br />-9s <br />sa,-``-fc, �F <br />s� <br />R=25' MIN.`_,,/ <br />(OPTIONAL) 12" MIN. a <br />4"-8" QUARRY SPALLS —7§k tPLACE GEOTEXTILE UNDER SPALLS <br />2 i 1 i <br />1£t " Erato openkvs <br />12" X 12" CATCH BASIN WITH 2 OPENINGS (NDS PART NO. 1200 OR EQUIVALENT) <br />12" ATRIUM GRATE (NDS PART NO. 1280 /1290 OR EQUIVALENT) <br />1- 4" UNIVERSAL OUTLET <br />1- 6" UNIVERSAL OUTLET <br />AREA DRAIN W/ ATRIUM GRATE DETAIL <br />REF: NDS PART NO.'S 1200 & 1280 <br />NO SCALE <br />ATTACH IN A MANNER THAT <br />POST SEE WSDOT STANDARD <br />ASSURES FABRIC IS FIRMLY <br />SPECIFICATIONS 8-01.3(9)A <br />HELD BY THE BACKUP <br />SUPPORT IN AWAY THAT <br />REDUCES THE POTENTIAL <br />FOR FABRIC TEARING <br />FASTEN GEOTEXTILE TO <br />POST EVERY 6" IN O.C. <br />BACKUP SUPPORT-----, <br />p Z <br />BACKFILLED & ^` SELF-LOCKING TIE-NYLONE <br />COMPACTED 996/6 (MIN GRADE) <br />NATIVE SOIL — ., TEXTILE `*CEO 120#MIN TENSILE STRENGTH, <br />UV STABILIZED <br />BURY GEOTEXTILE <br />IN TRENCH <br />1" VENT HOLE WHEN <br />NOT CONNECTED TO CS <br />(COMBINED SEWER) <br />6" PVC <br />FACTORY TEE: <br />FLOW <br />FROM RAIN GARDEN <br />0 <br />i— BEEHIVE GRATE <br />PVC PLUG <br />FLOATABLE MATERIAL SEPARATOR & GAS TRAP <br />BASED ON C.O.E. STD. DWG 410 <br />NO SCALE <br />PLAN VIEW <br />20" X 24" <br />10" X 12" <br />VA 0 0 ?j VA _T <br />6 1/4- <br />1 1/2- <br />20" X 24 <br />SECTION VIEW <br />BEEHIVE GRATE DETAIL <br />REF: OLYMPIC FOUNDARY PART NO. SM60BH <br />NO SCALE <br />BOTANICAL NAME <br />COMMON NAME <br />PLANTING ZONE <br />MATURE HEIGHT <br />PLANT SPACING <br />QUANTITY <br />JUNCUS ENSIFOLIUS <br />DAGGER LEAF RUSH <br />ZONE 1 <br />12" TO 18" <br />36" OC <br />15 <br />JUNCUS ACUMINATUS <br />TAPER TIPPED RUSH <br />ZONE 1 <br />6" TO 18" <br />24" OC <br />10 <br />IRIS TENAX <br />OREGON IRIS <br />ZONE 1 <br />12" TO 18" <br />12" OC <br />30 <br />TIARELLA TRIFOLIATA <br />FOAM FLOWER <br />ZONE 2 <br />12" <br />12" OC <br />30 <br />GEUM <br />AVENS <br />ZONE 2 & 3 <br />8" TO 20" <br />12" OC <br />30 <br />GERANIUM <br />CANTABRIGIENSE <br />BIOKOVO HARDY <br />GERANIUM <br />ZONE 2 & 3 <br />6" TO 8" <br />8" OC <br />60 <br />VJ <br />�- V <br />Z Z <br />cWry <br />0O <br />J � < H F— <br />CD <br />Q -Iz <br />06 � I.I.J (n 3 <br />`0 3:° <br />F- W = W <br />O W <br />Z `` O W W <br />/ _ rW <br />W <br />Z W <br />J <br />ry v <br />V <br />v <br />o <br />Z <br />N <br />to N <br />o <br />ZW <br />`� o� <br />I- <br />I r: <br />` <br />/ Q <br />N <br />01 AbILiLcU UUIN5 I KUV I IUN CN I KANUt I EMNURARY SILT FENCE p v > W vi <br />No SCALE PER C.O.E. sm. DWG 214 TYPICAL RAIN GARDEN PLANTING ZONES RAIN GARDEN PLANTING SCHEDULE — 0 Cc <br />NO SCALE PER RAIN GARDEN HANDBOOK FOR WESTERN WASHINGTON <br />NO SCALE a) a- <br />3 O W <br />Z N <br />of <br />O © Q <br />O <br />Q NOTES O <br />NOTES <br />DESIGN: <br />0 5" MAX 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it 1. SEE THE RAIN GARDEN HANDBOOK FOR WESTERN <br />WASHINGTON FOR DESIGN AND PLANTING <br />9WIII service. INSTRUCTIONS. NATIVE PLANTS ARE PREFERRED, Now <br />DRAINAGE GRATE TRIM BECAUSE NON-NATIVE AND INVASIVE SPECIES CAN REVISIONS: APPB. <br />9 2. The BIGD shall have a built-in high -flow relief system (overflow bypass). MOVE DOWNSTREAM AND DAMAGE HABITAT, IF <br />Z <br />NON -NATIVES ARE CHOSEN, BE SURE THAT THEY WILL <br />3. The retrievals stem must allow removal of the BIGD without spilling the NOT DAMAGE DOWNSTREAM HABITAT. <br />GRATE FRAME y p g <br />collected material. <br />5"-12" TYPICAL 2. RAIN GARDENS MAY BE USED TO MEET <br />PONDING DEPTH STORMWATER MINIMUM RECtUIREMENT#5 FOR <br />o ° a 4. Perform maintenance in accordance with Standard Specification 8-01.3 15 <br />SITES WHICH ADD OR REPLACE LESS THAN 5000 SF OF <br />O p ( ) 3H:1V SIDE SLOPE MAX TYPICAL NEW OR REPLACED HARD SURFACE. <br />SEDIMENT AND DEBRIS PLANTINGS <br />v CLEAN OUT SET CAP HIGHER <br />F- ° 4 THAN MAX WATER LEVEL 3. PROVIDE RAIN GARDEN INFORMATIVE SIGNS FOR <br />w OVERFLOW BYPASS --BERM AS NEEDED RAIN GARDEN ASSOCIATED WITH NEW <br />v <br />CONSTRUCTION. SIGNS ARE AVAILABLE FROM PERMIT <br />z COMPACTED NATIVE FILL 1-2." MULCH WIDTH (S' MIN) <br />EXISTING GRADE SERVICES. <br />RETRIEVAL SYSTEM 4. MAINTENANCE AGREEMENTS ARE REQUIRED FOR <br />D DRAINAGE GRATE <br />a ::s ,, BELOW INLET GRATE DEVICE (TYP) RAIN GARDEN INSTALLATION USED TO MEET <br />RECTANGULAR GRATE SHOWN STORMWATER MINIMUM REQUIREMENTS. <br />Olt—_ — — — = DATE: MARCH, 2017 <br />,� II —!I! II! !I! —!I! _ �!—I!! !I� !II- <br />�, FILTERED��/f�, ! ! !—! ! !®I l I ! ! ( ! ! I—_ _ — —,� <br />_ _ _ ! ! I-iIII I � I_I ! !—� � ! `� DESIGN: JNM <br />WATER�,i !=! I !—! I !—! !=! ! ! I ! ! !-_ -! !—! I !—! !—! —I I !_! !=! I !=I I !=! !'� CONSTRUCTION: <br />t— I— DRAWN: APDC <br />1, BUILD AND VEGETATE RAIN GARDEN AS EARLY AS <br />-. r,d—1 !- =III=III=Ill=l III=II 111=Ill= `i EXCAVATE AT STABLE POSSIBLE TO ESTABLISH PLANTINGS BEFORE CHECKED: <br />U z — — m — ANGLE FOR REVISION <br />Q ' - DIRECTING STORMWATER RUNOFF TO IT, <br />fl NATIVE SOIL <br />2. INFILTRATION AREAS (THE AREA OF THE RAIN NUMBER: <br />0 cr �'�/ 6 MIN ,,, /�\' GARDEN AS DEFINED BYTHE TOP ELEVATION OF THE NUNN <br />cc �ti � <br />a Q `wFACILITY) SHALL BE FENCED OFF FROM THE FIRST DAY <br />�r i'l� OF EARTH MOVING UNTIL PROJECT COMPLETION TO <br />SCALE: AS NOTED <br />E � OVERFLOW BYPASS 1/2"-3/8" WASHED GRAVEL ��, ,,.�/� <br />IL '�l AMENDED PLANTING SOIL PREVENT COMPACTION OFTHE SUBGRADE, DIRT <br />o BELOW INLET GRATE DEVICE (TYP) CLEAN COARSE SAND , TRACKING ONTO ANY LAYER OF THE FACILITY AND <br />U D ° (WSDOT 5TO SPEC 9-03.13) STOCKPILING OF CONSTRUCTION MATERIALS THAT PROJECT NUMBER: <br />CL U MAY CLOG THE SURFACE. <br />o. o <br />QQ D D 6" MIN <br />f� '� p <br />° D D UNIFORMLY GRADED {�\ ��{ TYPE 1-L CB WITH BEEHIVE GRATE RMCA0000-0000 <br />MIN SUMP DEPTH 3. DURING EXCAVATION OF NATIVE SOILS TO THE <br />m m D D p STORAGE ROCK BOTTOM OF THE FACILITY, RAINFALL MAY CAUSE <br />(WSDOT STD SPEC 9-03.12(5) NON -PERFORATED OVERFLOW <br />OR EQUIVALENT) PIPE DIRECTED TO APPROVED DISPOSAL POINT FINES TO CLOG THE SURFACE OF THE FACILITY. IF THE DRAWING FILE: <br />ISOMETRIC VIEW NATIVE SOIL HAS BEEN EXPOSED TO RAINFALL, HAND <br />RAKE THE SURFACE TO A DEPTH OF 3" TO RESTORE <br />Q SECTION VIEW UNDISTURBED NATIVE 3" DEPTH 3/4" DRAIN ROCK, OPT INFILTRATION CAPACITY. Ec—IM-004—RMCA0009.dwg <br />N r' <br />SUBGRADE <br />ao r <br />�o <br />O N <br />N p� <br />T_ e- <br />LO V <br />ma <br />�; <br />COMPACTED NATIVE SUBGRADE 4. DURING AREA DRAIN INSTALLATION, DISTURB NATIVE <br />6°' PERFORATED PVC PIPE, <br />SOILS AS LITTLE AS POSSIBLE. SHEET NO. <br />STORM DRAIN INLET PROTECTION S=0.0000 <br />REF: WSDOT STD PLAN 1-40.20-00 RAIN GARDEN WITH U N D E R D RA I N <br />NO SCALE C4 <br />BASED ON C.O.E. STD. DWG 427 OF '4 <br />0 in NO SCALE <br />