Laserfiche WebLink
Structural <br />Structural <br />43V�`tt� <br />J <br />3311�:�lliiT <br />GLU=LAMINATED TIMBERS SHALL BE MANUFACTURED AND INDENTIFIED AS <br />REQUIRED IN A.I.T.C. A 1901.1 AND ASTM D 3737. GLU-LAMINATED WOOD <br />BEAMS, DOUGLAS FIR COAST REGION, KILN CRIED, A.I.T.C. SPECIFICATION <br />24F-V4 FOR SIMPLE SPANS, AND 24F-V8 FOR CANTILEVER SPANS (Fb m 2400 <br />PSI TENSION, TYPICAL). PROVIDE A.I.T.C. STAMP ON TIMBER AND SUBMIT <br />CERTIFICATE TO "ARCHITECT". MATERIALS MUST BE OBTAINED FROM AN <br />A.I.T.C. APPROVED FABRICATOR, ALL GLU-LAM BEAMS SHALL FIT SNUG AND <br />TIGHT IN THEIR CONNECTIONS AND DEVELOP FULL BEARING AS INDICTED. NO <br />SUBSTITUTION OF OTHER SPECIES. GLU-LAM ADHESIVE TO BE `WET -USE" <br />TYPE. <br />l <br />Notes <br />55 <br />E <br />Sk� <br />PL O D WEB JOI T. <br />DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST <br />EDITION I.C.C. REPORT ESR-11 53 FOR TJI (ESR-1405 FOR PRI JOIST 1225 FOR <br />PWI 1305 FOR LPI). CONNECTIONS AND BEARING MATERIAL TO BE SHOP <br />CONNECTED TO JOISTS AND DESIGNED AND FURNISHED BY JOIST <br />FABRICATOR. <br />CALCULATIONS SHALL INCLUDE DEFLECTION AND CAMBER REQUIREMENTS. <br />DEFLECTION SHALL BE LIMITED AS FOLLOWS: <br />FLOOR LIVE LOAD MAXIMUM =L/480, FLOOR TOTAL MAXIMUM =L/240. <br />ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT <br />MECHANICAL AND APPLIANCE EQUIPMENT. <br />wiffma,a - <br />FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF GRADING <br />RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION OR THE WEST <br />COAST LUMBER INSPECTION BUREAU. ALL SAWN LUMBER SHALL BE STAMPED <br />WITH GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY AND SHALL <br />HAVE THE FOLLOWING UNADJUSTED DESIGN MINIMUM PROPERTIES. <br />JOISTS: 2x4 DF. NO.2 <br />2x0 OR LARGER DF. NO.2 <br />BEAMS. WIDTH 4" OR LESS DF. NO.2 <br />GREATER THAN 4" DF. NO.2 <br />LEDGERS AND TOP PLATES. ALL SIZES DF. NO.2 <br />STUDS. ALL SIZES DF. NO.2 <br />POSTS: ALL SIZES DF, NO.2 <br />WOOD GENERAL. <br />DOUBLE UP FLOOR JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" <br />SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. DOUBLE UP STUDS AT JAMBS <br />AND BEAMS GREATER THAN 6-0" SPAN. EVERY OTHER STUD OF WOOD FRAME <br />BEARING WALLS SHALL HAVE A SIMPSON H3 ANCHOR TOP AND BOTTOM, <br />EXCEPT AT THOSE WALLS WHERE PLYWOOD SHEATHING IS DIRECTLY <br />ATTACHED TO THE TOP AND BOTTOM PLATES WITH EDGE NAILING, PROVIDE <br />2x SOLID 61-OCKING AT MID HEIGHT OF BEARING STUD WALLS. ALL NAILING <br />NOT NOTED SHALL BE ACCORDING TO TABLE 2304.9.1 OF THE INTERNATIONAL <br />BUILDING CODE. ALL MELD CUT ENDS, NOTCHES AND DRILLED HOLES OF <br />PRESSURE TREATED WOOD SHALL BE RETREATED IN FIELD ACCORDANCE <br />WITH AWPA M4. WOOD CONNECTORS SHALL BE AS MANUFACTURED BY <br />SIMPSON STRONG -TIE COMPANY, INC. OR OTHER MANUFACTURER WITH <br />CURRENT AND EQUIVALENT I.C.C. APPROVAL. ALL WOOD CONNECTORS IN <br />CONTACT WITH PRESSURE TREATED OF FIRE RETARDANT WOOD SHALL BE <br />HOT -DIPPED GALVANIZED STEEL OR APPROVED EQUAL, TYPICAL UNLESS <br />NOTED OTHERWISE, TYPICAL CONNECTIONS SHALL USE THE FOLLOWING <br />SIMPSON STRONG -TIE CONNECTORS, UNLESS NOTED OTHERWISE. <br />CONNECTION TYPE TYPICAL CONNECTOR <br />POST TO FOUNDATION: ABU TYPE POST BASE <br />POST TO BEAM: PC TYPE POST CAP <br />JOLT TO BEAM: LU TYPE HANGER <br />BEAM TO BEAM: HU TYPE HANGER <br />u <br />Notes <br />Structral <br />-EXUAL ICI - <br />BUILDING -CO —DE' <br />2018 EDITION OF THE INTERNATIONAL BUILDING AND RESIDENTIAL CODE. <br />LOADS: <br />ROOF LIVE LOAD =25 PSF (SNOW) <br />ROOF DEAD LOAD =15 PSF <br />FLOOR LIVE LOAD =,40 PSF <br />FLOOR DEAD LOAD =15 PSF <br />STAIR LIVE LOAD =100PSF <br />WIND LOAD =110 MPH,EXPOSURE B <br />SEISMIC DESIGN CATEGORY D <br />OUNDA1 O <br />SPREAD FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED SOIL 13" MINIMUM BELOW <br />FINISHED GRADE, FINISHED GRADE IS DEFINED AS TOP OF SLAB FOR INTERIOR <br />FOOTINGS AND LOWEST ADJACENT GRADE WITHIN 5 FEET FOR PERIMETER <br />FOOTINGS. DESIGN SOIL BEARING VALUE = 1,500 PSF. <br />MINIMUM COMPRESSIVE STRENGTH OF CONCRETE SHALL BE 3,000 PSI TO <br />COMPLY WITH EXPOSURE REQUIREMENTS OF IBC TABLE 1904.2.2. STRUCTURAL <br />DESIGN IS BASED ON f"c OF 2,500 PSI. PER IBC 1705.3, NO SPECIAL INSPECTION <br />REQUIRED, <br />ALL CONCRETE CONSTRUCTION SHALL CONFORM TO A.G.I. MECHANICALLY <br />VIBRATE ALL CONCRETE WHEN GLACE, EXCEPT THAT SLABS ON GRADE NEED TO <br />BE VIBRATE ONLY AT TRENCHES, FLOOR DUCTS, TURNDOWNS, ETC,. MAXIMUM <br />SLUMP OF 4 1 /2" FOR CONCRETE WITHOUT PLASTICIZER. IF PLASTICIZER IS USED, A <br />HIGHER FINAL SLUMP MAY BE ALLOWED UPON APPROVAL BY "ARCHITECT". <br />UNLESS APPROVED OTHERWISE IN WRITING BY THE "ARCHITECTT", ALL CONCRETE <br />SLABS ON GRADE SHALL BE BOUND BY CONTROL JOINTS (KEYED OR SAW CUT), <br />AS SHOWN ON FOUNDATION, FLOOR OR SITE PLAN, SUCH THAT THE ENCLOSED <br />AREA DOES NOT EXCEED 200 SQUARE FEET. KEYED CONTROL JOINTS NEED ONLY <br />OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW <br />CUT, <br />FLY ASH, UPON "ARCHITECTS APPROVAL SHALL BE LIMITED TO 13% OF <br />CEMENTITOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 <br />RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN <br />FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. <br />RFINF )- CIhtG�� Ell' <br />ASTM A615 (Fy = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM <br />A615 (Fy = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER, NO TACK <br />WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF <br />PROCEDURE. LASEST A.C.I. CODE AND DETAILING MANUAL APPLY, CLEAR <br />CONCRETE COVERAGES AS FOLLOWS: <br />CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" <br />EXPOSED TO EARTH OR WEATHER <br />#6 BARS OR LARGER 2" <br />#5 BARS ARID SMALLER 1 1/2" <br />ALL OTHER PER A.C.I.318-11. <br />LAP SPLICES IN CONCRETE: <br />LAP SPLICES, UNLESS NOTED OTHI RWISE,SHALI BE CLASS "B" TENSION LAP SPLICES <br />PER LATEST EDITION OF A.C.I.318. STAGGER SPLICES A MINIMUM OF ONE LAP PER <br />LENGTH. ALL REINFORCING MUST PROVIDE ISOLATION FROM MOISTURE/ <br />CORROSION. <br />PROVIDE BENT CORNER BARS TO MATCH ARID LAP WITH HORIZONTAL BARS AT <br />ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. REINFORCING BAR <br />SPACING ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND <br />HANDBOOK, DOWEL ALL VERTICAL REINFORCING INTO FOUNDATION WITH <br />STANDARD 90 DEGREE HOOKS UNLESS NOTED OTHERWISE. SECURELY TIE ALL BARS <br />IN LOCATION BEFORE PLACING CONCRETE. <br />t <br />Notes <br />a1 <br />PCB. Box 665 Freeland <br />Washington 98249 <br />206-283-8317 <br />pagearchitects@gmail.com <br />www.williampagearchitect.com <br />Issue/Revisions <br />No. Date Comments <br />'MUM MES ME 11 <br />'A FAI <br />Copyright 2021 William Page Architects <br />Project <br />Van Patten Residence <br />924105th Place SE. <br />Everett, Washington <br />Sheet Title <br />Structural Metes <br />