Laserfiche WebLink
0 <br />BUILDING AIR LEAKAGE SEALS & WEATHER STRIPPING <br />(R402.4) EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS <br />BETWEEN WALLS AND FOUNDATION, WALLS OR ROOFS AND ALL OTHER <br />PENETRATIONS SHALL BE SEALED, CAULKED, GASKETED OR WEATHER STRIPPED TO <br />LIMIT AIR LEAKAGE. OTHER EXTERIOR JOINTS SHALL BE SIMILARLY TREATED, TAPED <br />OR COVERED WITH MOISTURE VAPOR PERMEABLE WRAP, <br />BUILDING AIR LEAKAGE TESTING (R402,4.1.2 TESTING) <br />AS REQUIRED BY INSPECTOR, VERIFY WITH EACH PROJECT. EXISTING/REMODEL <br />PORTIONS OF HOUSE DO NOT REQUIRE BLOWER DOOR TEST. ONLY ADDITION AND <br />NEW CONSTRUCTION REQUIRE BLOWER DOOR TESTING, ADDITION/NEW <br />CONSTRUCTION SHALL NOT EXCEED 5 AIR CHANGES PER HOUR. TESTING TO BE <br />PERFORMED BY APPROVED 3rd PARTY. PERFORM TESTING PER WSEC <br />REQUIREMENTS. <br />HVAC CONTROLS <br />EACH DWELLING UNIT IS REQUIRED TO HAVE ONE PROGRAMMABLE THERMOSTAT <br />FOR THE REGULATION OF TEMPERATURE PER EACH SYSTEM. <br />DUCT TESTING <br />R403.2.2 DUCTS SHALL BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33, IF NOT <br />ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE, R403.2.1 DUCT SHALL BE <br />INSULATED WITH RB MIN. <br />LIGHTING <br />R404.1 A MIN. OF 90% OF PERMANENTLY INSTALLED LAMPS SHALL- BE HIGH <br />EFFICIENCY. <br />ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS R405.1 SCOPE. THIS <br />SECTION ESTABLISHES OPTIONS FORADDITIONAL CRITERIATO BE DIET FOR <br />ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES, AS DEFINED IN <br />SECTION 101.2 OF THE INTERNATIONAL RESIDENTIAL CODE, AND DWELLING <br />UNITS IN RESIDENTIAL BUILDINGS TO DEMONSTRATE COMPLIANCE WITH THIS <br />CODE. R406.2 ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS (MANDATORY). <br />EACH DWELLING UNIT IN A RESIDENTIAL BUILDING TALL COMPLY WITH <br />SUFFICIENT OPTIONS FROM TABLE R406.2 SO AS TO ACHIEVE THE FOLLOWING <br />MINIMUM NUMBER OF CREDITS: <br />1. SMALL DWELLING UNIT: ..... - .................3.0 CREDITS DWELLING UNITS LESS <br />THAN 1500 SQUARE FEET IN CONDITIONED FLOOD AREA WITH LESS TITAN 390 <br />SQUARE FEET OF FENESTRATION AREA, ADDITIONS TO <br />EXISTING BUILDING GREATER THAN 500 SQUARE FEET OF HEATED FLOOR <br />AREA BUT LESS THAN 1500 SQUARE FEET. <br />2. MEDIUM DWELLING UNIT... ...... ....... _ 6.0 CREDITS ALL DWELLING UNITS THAT <br />ARE NOT INCLUDED IN #1 OR 93. EXCEPTION: DWELLING UNITS SEWING R-2 <br />OCCUPANCIES SHALL REQUIRE 2.5 CREDITS. <br />3. LARGE DWELLING UNIT..... 7.0 CREDITS DWELLING UNITS <br />EXCEEDING 5000 SQUARE FEET OF CONDITIONED FLOOR AREA. EXCEPTION: <br />DWELLING UNITS SERVING R-2 OCCUPANCIES SHALL REQUIRE <br />2.5 CREDITS. <br />4. ADDITIONS LESS THAN 500 SQUARE FEET. 1.5 CREDITS. THE DRAWINGS <br />INCLUDED WITH THE BUILDING PERMIT APPLICATION SHALL IDENTIFY WHICH <br />OPTIONS HAVE BEEN SELECTED AND THE POINT VALUE OF <br />EACH OPTION, REGARDLESS OF WHETHER SEPARATE MECHANICAL, <br />PLUMBING, ELECTRICAL, OR OTHER PERMITS ARE UTILIZED FOR <br />THE PROJECT. <br />MOISTURE VAPOR RETARDERS <br />IRC R601.3 INSTALL A VAPOR RETARDER SUCH AS KRAFT/PAPER FACED <br />INSULATION, VAPOR RETARDING PAINT, VAPOR RETARDING FOIL OR OTHER <br />APPROVED VAPOR RETARDERS IN ALL FRAMED WALLS, FLOORS AND CEILING <br />ELEMENTS OF THE CONDITIONED BUILDING ENVELOPE ON THE WARM (WINTER) SIDE <br />OF INSULATION. IN WET AREAS SUCH AS SHOWER STALLS INSTALL VAPOR BARRIER <br />BEHIND TILE BACKER BOARD OR INSTALL A WATERPROOF MEMBRANE OVER TILE <br />BACKER BOARD. INSTALL VAPOR BARRIER BEHIND BATH TUBS AND SHOWERS. <br />REMODEL/ADDITIONS <br />R101.4.3 REMODELS AND ADDITIONS SHALL CONFORM TO ENERGY CODE AS THEY <br />RELATE TO NEW CONSTRUCTION. EXPOSED EXISTING CAVITIES SHALL BE FILLED WITH <br />INSULATION. 2x4 FRAMING AMID R15, 2x6 FRAMING ADD R21. <br />INSULATION GLAZING/VAPOR RETARDER <br />RESIDENTIAL SPACES SHALL CONFORM TO THE FOLLOWING CRITERIA <br />2013 WASHINGTON STATE ENERGY CODE, TABLE R402.1.1, "INSULATION AND <br />FENESTRATION REQUIREMENTS BY COMPONENT" FOR CLIMATE ZONE MARINE 4 <br />FENESTRATION U-FACTOR 0.23 <br />SKYLIGHT U-FACTOR 0.50 <br />GLAZING FENESTRATION SHGC NR <br />CEILING R-FACTOR R49EXCEPT SINGLE RAFTER/JOIST/ <br />VAULTED CEILINGS CAN BE REDUCED TO R33 <br />WOOD FRAME WALLS R21 INT. <br />MASS WALL R21 /21 <br />FLOOR R30 <br />BELOW GRADE WALLS R10 CONTINUOUS ON THE EXTERIOR <br />OF THE WALL, OR RI ON THE CONTINUOUS INSULATION ON THE INTERIOR OF THE <br />WALL, OR R21 CAVITY INSULATION PLUS A THERMAL BREAK BETWEEN THE SLAB AND <br />THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL. <br />SLAB R10,FOR 2FT. <br />SEE GLAZING CALCULATIONS ON WINDOW SCHEDULE, <br />STAIRWAYS SHALL HAVE A MIN. WIDTH OF 36". HAND RAILS MAY ENCROACH <br />A MAX. OF 3 1 /2" INTO THE REQUIRED WIDTH. <br />TREADS SHALL HAVE A MIN. WIDTH OF 10". STAIR TREADS MUST BE UNIFORM AND <br />CAN NOT VARY FROM THE LARGEST TO THE SMALLEST BY MORE THAN 3/9". <br />STAIRWAYS SHALL HAVE MIN. 6-8" OF HEADROOM AT THE NOSE OF THE STAIR, <br />ENCLOSED USABLE SPACE UNDER INTERIOR STAIRS SHALL BE PROTECTED ON THE <br />ENCLOSED FACE WITH 5/3" TYPE "X" GYPSUM WALL BOARD. <br />STAIRWAYS SHALL HAVE AT LEAST ONE HANDRAIL LOCATED 34" TO 39" ABOVE THE <br />NOSING OF TREADS AND LANDINGS. THE HAND GRIP PORTION OF HANDRAILS <br />SHALL NOT BE LESS THAN 1-1 /2" OR GREATER THAN 2" IN CROSS -SECTIONAL <br />DIMENSION. <br />HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. THE ENDS OF <br />HANDRAILS SHAD- RETURN TO WALL OR TERMINATE INTO A NEWEL POST OR <br />SAFETY TERMINAL. <br />STAIRWAYS HAVING LESS THAN 4 RISERS DO NOT REQUIRE A HAND RAIL. <br />36" MIN. HEIGHT GUARDRAILS SHALL BE PROVIDED FOR AT PORCHES, DECKS, <br />BALCONIES, STAIRWAYS AND LANDINGS WHERE THE ADJACENT SURFACE IS <br />GREATER THAN 30" BELOW. <br />RAILING AND GUARDRAIL BALUSTER SPACING SHALL BE LESS THAN 4". <br />THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF <br />GUARDRAIL SHALL NOT ALLOW A 6" DIAMETER SPHERE TO PASS THROUGH. <br />EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW WITH FINISH <br />SILL HEIGHT NOT GREATER THAN 44" ABOVE THE FINISH FLOOR HEIGHT AND SHALL <br />HAVE A MINIMUM OPEN AREA OF 5.0 SQ. FT. ON FIRST FLOOR AND 5.7 SQ. FT. ON <br />FLOORS ABOVE LEVEL 1 EGRESS WINDOWS SHALL NOT HAVE AN OPEN AREA LESS <br />THAN 20" WIDE OR 24"HIGH, <br />DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" TIGHT FITTING <br />SOLID CORE DOORS WITH A RATING OF 20 MINUTES. DOOR SHALL BE SELF <br />CLOSING <br />EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOORWAY SHALL BE 32" MIN. <br />DOOR SHALL BE OPEN FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY <br />GLASS WITH MIN. -VALUE OF 0.30 <br />LEQj GAL jMt : <br />HOME OWNERAND ARCHITECT SHALL DO A WALK-THRU WITH RELEVANT <br />INSTALLERS TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, <br />SWITCHES, CABLE, DATA, PHONE, AUDIO, ETC. <br />ELECTRICAL NOTES: <br />1. ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES <br />SHALL BE G.F,I. OR G.F.LC. OR ARC FAULT PER NATIONAL, STATE <br />ELECTRICAL CODE REQUIREMENTS. <br />2. PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH <br />CORRIDOR ACCESSING BEDROOMS. CONNECT SMOKE DETECTORS TO <br />HOUSE POWER AND INTER -CONNECT SMOKE DETECTORS SO THAT, <br />WHEN ANY ONE IS TRIPPED, T HEYALL WILL SOUND. PROVIDE BATTERY <br />BACKUP FOR ALL UNITS. <br />3. CIRCUITS SHALL BE !VERIFIED WITH HOME OWNER AND ARCHITECT <br />PRIOR TO WIDE INSTALLATION. <br />4. FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH <br />DOME OWNER AND ARCHITECT. <br />- <br />M M A 1 t. <br />INSULATE WASTE LIKES FOR SOUND CONTROL <br />N <br />SECTION R806 IRC ENCLOSED ATTICS AND RAFTERS SPACES WHERE CEILINGS ARE <br />APPLIED TO UNDERSIDE SHALL HAVE CROSS VENTILATION WITH 1/8"-1/4" <br />CORROSION RESISTANT WIRE MESH, <br />THE TOTAL NET FREE VENTILATION AREA NOT LESS THAN 1 /150 OF TOTAL AREA <br />EXCEPT AREAS THAT PROVIDE 50-30% OF REQUIRED VENTING IN THE UPPER <br />PORTION AND AT LEAST 3 FEET ABOVE EAVE AND BALANCE AT EAVES, OR A <br />VAPOR RETARDER NOT EXCEEDING 1 PERM IS INSTALLED ON WARM SIDE OF <br />INSULATION. <br />WHERE VENTING OCCURS ADD BAFFLES TO DEFLECT AIR ABOVE INSULATION. <br />INSULATION SHALL NOT BLOCK THE FLOW OF AIR. A MIN. OF 1" AIR SPACE ABOVE <br />INSULATION AND ROOF SHEATHING. <br />CROSS VENTILATION OF RAFTER BAYS AT VALLEY, EY, SKYLIGHTS OR OTHER <br />OBSTRUCTION. NOTCHING OR DRILLING OF HOLES PER IRC 302.7 <br />ATTIC ACCESS IF AREA EXCEEDS 30 SF. AND A 30" VERTICAL HEIGHT MEASURED <br />BETWEEN FRAMING MEMBERS. ROUGH FRAMED AREA 22"x30" IN AN ACCESSIBLE <br />AREA. IN ACCESS IS IN HEATED AREA THEN INSULATE HATCH AND WEATHER STRIP. <br />M1507 IS REQUIRED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY <br />ROOM, AND OTHER ROOMS WHERE EXCESSIVE WATER VAPOR AND ODOR IS <br />PRODUCED. <br />BATHROOM 50 CFM MIN. INTERMITTENT, OR 20 CFM CONTINUOUS <br />KITCHEN 90 CFM MIN. INTERMITTENT, OR 25 CFM CONTINUOUS <br />PROVIDE A MOTORIZED MIXING DAMPER INTERCONNECTED WITH AIR HANDLING <br />FAN AND A 24 HOUR TIMER. HVAC TO COMPLY WITH M 1503 FOR SIZING OF <br />DUCTS,DAMPERS, VENTILATION RATE, FAN NOISE AND ALL OTHER REQUIREMENTS. <br />ALL GAS APPLIANCES REQUIRING FRESH AIR INTAKE AND EXHAUST DIRECT TO <br />OUTSIDE AND HAVE SEALED COMBUSTION CHAMBERS. <br />EXHA S_ <br />KITCHEN RANGE, CLOTHES DRYERS DUCTING TO HAVE SMOOTH INTERIOR DUCTS, <br />AIR TIGHT VENTED TO OUTSIDE WITH BACK DRAFT DAMPERS. DUCTS SHALL NOT BE <br />INSTALLED WITH SCREWS WHICH WOULD OBSTRUCT FLOW, 4" MIN. DIAMETER AND <br />MAX. IR COMBINED VERT./HORIZ. RUN WITH MAX. TWO 90 DEGREE TURNS, <br />DEDUCT 2' PER 90 DEGREE TURN OVER TWO MAX. <br />HVAC AND PLUMBING PERFORMED IN A "BIDDER -DESIGN MANNER UNO. THE <br />CONTRACTOR SHALL SUBMIT SUCH SYSTEMS SEPARATELY FOR PERMIT.IT IS THE <br />CONTRACTOR RESPONSIBILITY TO TO DESIGN THE SYSTEMS TO MEET ALL <br />REQUIREMENTS AND CODE. CONTRACTOR SHALL SUBMIT DRAWINGS, PAY FOR <br />AND OBTAIN PERMITS AND PERFORM WORK IN A MANNER THAT EXCEEDS <br />WORKMANSHIP FOR THE INDUSTRY. <br />ALL DRAWINGS ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL TO THE <br />OWNER BEFORE PERFORMING WORK. <br />THE HEATING FOR THIS PROJECT IS EXISTING AND NEW ELECTRIC WALL UNITS WITH <br />FAN. <br />APPLIANCES INSTALLED IN AREAS SUBJECT TO DAMAGE SHALL BE INSTALLED <br />BEHIND BOLLARDS OF STEEL OR CONCRETE. GAS EQUIPMENT IN GARAGES SHALL <br />BE ELEVATED 1 B" ABOVE FLOOR LEVEL <br />fi <br />INSTALL SILT FENCE PRIOR TO ANY EXCAVATION OR CONSTRUCTION <br />MINIMIZE SITE DISTURBANCE BY TIGHT CONTROL OF EXCAVATION LIMITS. <br />ALL EXPOSED SOIL SHALL BE MULCHED WITH STRAW OR WOOD CHIPS TO <br />MINIMIZE SOIL EROSION. NO SOIL SHALL BE LEFT IN AN EXPOSED CONDITION. IT IS <br />RECOMMENDED THAT THE CONTRACTOR MAINTAIN A STOCK PILE OF THIS <br />MATERIAL ON SITE FOR QUICK APPLICATION. <br />HYDROSEED WITH A WOOD CELLULOSE FIBER MULCH APPLIED AT A RATE OF <br />2,000#/ACRE. USE AN ORGANIC TACKIFIER AT NO LESS THAN 150 it/ACRE OR <br />PER MANUFACTURE'S RECOMMENDATION IF HIGHER. APPLICATION OF <br />TACKIFIER SHALL BE HEAVIER AT EDGES, IN VALLEYS AND AT CRESTS OF BANKS <br />AND OTHER AREAS WHERE SEED CAN BE MOVED BY WIND OR WATER. <br />CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UTILITIES. <br />PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. <br />FINAL GRADE TO CONVEY SURFACE DRAINAGE TOWARDS DOWN HILL. <br />AREAS TO BE FILLED SHALL BE CLEARED, GRUBBED TO REMOVE TREES, <br />VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL AND STRIPPED OF <br />TOPSOIL. <br />I ItIll!1I <br />4 <br />r <br />LS -S 0- S : <br />EACH BEDROOM TO HAVE A MINIMUM WINDOW OPENING OF 5.0 SQ.FT. FIRST <br />FLOOR, 5.7 SQ. FT. ABOVE FIRST LEVEL WITH A MINIMUM WIDTH OF 20 IN. AND <br />HEIGHT OF @24 IN. AND A SILL LESS THAN 44" ABOVE FIN. FLR. <br />ALL GLAZING WITHIN 13 IN, OF THE FLOOR AND/OR WITHIN 24 IN, OF ANY DOOR <br />(REGARDLESS OF WALL PLANE) ARE TO HAVE SAFETY GLAZING. ALL GLAZING <br />WITHIN 60 IN. OF TUB OR SHOWER FLOOR, 60 IN, OF A STAIR LANDING OR <br />GREATER THAN 9 SQUARE FEET ARE TO HAVE SAFETY GLAZING <br />SKYLIGHTS ARE TO BE GLAZED WITH TEMPERED GLASS ON OUTSIDE AND <br />LAMINATED GLASS ON THE INSIDE (UNLESS PLEXIGLAS). GLASS TO HAVE <br />MAXIMUM CLEAR SPAN OF 25 IN, AND FRAMF IS TO BE ATTACHED TO A 2x CURB <br />WITH A MINIMUM OF 4 IN. ABOVE ROOF PLANE. <br />ALL TUB AND SHOWER ENCLOSURES ARE TO BE GLAZED WITH SAFETY GLASS. <br />ALL EXTERIOR WINDOWS ARE TO BE DOUBLE GLAZED AND ALL EXTERIOR DOORS <br />ARE TO BE SOLID CORE WITH WEATHERSTRIPPING. PROVIDE 1/2 IN. DEADBOLT <br />LOCKS ON ALL EXTERIOR DOORS, AND LOCKING DEVICES ON ALL DOORS AND <br />WINDOWS WITHIN 10 FT. (VERTICAL) OF GRADE. <br />PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH CORRIDOR <br />ACCESSING BEDROOMS. CONNECT SMOKE DETECTORS TO HOUSE POWER AND <br />INTER -CONNECT SMOKE DETECTORS TO HOUSE POWER AND INTERCONNECT SO <br />THAT, WHEN ANY ONE IS TRIPPED, THEY ALL WILL SOUND. PROVIDE BATTERY <br />BACKUP FOR ALL UNITS. ONE CARBON MONOXIDE DETECTOR OUTSIDE OF <br />BEDROOMS. <br />ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE <br />G.F.I.OR G.F.I.C. AND ARCHFAULT PER NATIONAL AND STATE ELECTRICAL CODE <br />REQUIREMENTS. <br />INSTALL WATERPROOF GYPSUM BOARD AT ALL WATER SPLASH AREAS TO <br />MINIMUM 7W ABOVE SHOWER DRAINS, <br />INSULATE WASTE LINES FOR SOUND CONTROL. <br />ALL RECESSED LIGHTS IN INSULATED CEILINGS TO HAVE THE I.C. LABEL. <br />PROVIDE SOLID BLOCKING UNDER ALL BEARING WALLS PERPENDICULAR TO <br />JOISTS AND OTHER BEARING POINTS NOT OTHERWISE PROVIDED WITH SUPPORT. <br />ALL EXTERIOR OPENINGS,FLASHINGS,COUNTER FLASHINGS,EXPANSION JOINTS <br />SHALL BE CONSTRUCTED IN A MANNER TO MAKE THEM WATER PROOF. <br />DRAWI -�1 <br />RENDERINGS ARE NOT TO SCALE,' ALL RENDERINGS ARE FOR ARTISTIC DEPICTION <br />ONLY. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS <br />SHALL NOT BE USED FOR CONSTRUCTION. <br />THE FOLLOWING DOCUMENTS REQUIRE THAT SOME ASSUMPTIONS BE MADE <br />CONCERNING THE SITE ,UTILITIES AND THE BUILDINGS. THE CONTRACTOR SHALL <br />VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES PRIOR TO <br />CONTINUING WORK. <br />WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER <br />SCALED DIMENSIONS. THE GENERAL CONTRACTOR SHALL VERIFY AND IS <br />RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS) AND <br />CONDITIONS ON THE JOB AND MUST NOTIFY THIS OFFICE OF ANY VARIATIONS <br />FROM THESE DRAWINGS. DO NOT SCALE DRAWINGS, IF A DIMENSION IS MISSING <br />CONTACT ARCHITECT. <br />WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER <br />SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE <br />CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT <br />ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR <br />NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. <br />CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS <br />(INCLUDING ROUGH OPENINGS). <br />THE INTENT OF THE CONSTRUCTION DOCUMENTS IS TO INCLUDE ALL ITEMS <br />NECESSARY FOR THE COMPLETION OF WORK. WORK NOT COVERED IN THE <br />CONSTRUCTION DOCUMENTS WILL NOT BE REQUIRED UNLESS IT IS REASONABLY <br />INFERRED AS BEING NECESSARY TO PROVIDE THE INTENDED RESULTS. WRITTEN <br />SPECIFICATIONS AND GENERAL REQUIREMENTS SHALL HAVE PRECEDENCE OVER <br />DRAWINGS. DAMAGED OR DEFECTIVE WORK OR MATERIAL SHALL BE <br />IMMEDIATELY REPAIRED OR REPLACED TO THE APPROVAL OF THE ARCHITECT <br />AND AT NO ADDITIONAL COST TO THE OWNER. <br />ALL DIMENSIONS ARE TO FACE OF STUDS,MASONRY OR CONCRETE UNLESS <br />NOTED OTHERWISE. <br />CROSS SECTIONS AND DETAILS SHOWN DO NOT NECESSARILY INDICATE ALL LIKE <br />CONDITIONS AND DO NOT LIMIT THE APPLICATION OF ANY DRAWING,SECTION <br />OR DETAILS THAT MAY APPLY TO OTHER SAME OR SIMILAR CONDITION NOT <br />REFERENCED. <br />PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. <br />THE SURVEY INFORMATION HAS BEEN SUPPLIED BY SNOHOMISH COUNTY <br />ASSESSOR MAP <br />WILLIAM PAGE ARCHITECTS DOES NOT TAKE ANY RESPONSIBILITY FOR ANY <br />ERRORS OR OMISSIONS. <br />HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF <br />REGIONAL AND LOCAL CODES. SEE CALCULATIONS. PORCHES, DECKS, <br />FOUNDATION, FIREPLACE ENCLOSURES, AND GARAGE AREAS NOT INCLUDED IN <br />LIVING AREA, ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR. ALL <br />PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK OR <br />FOAM. <br />INSTALL FOAM TYPE INSULATION AT FLOOR AND PLATE LINES, OPENINGS IN <br />PLATES, CORNER STUD CAVITIES AND AROUND DOOR AND WINDOW ROUGH <br />OPENING CAVITIES. <br />INSULATE ALL ACCESS DOORS/ HATCHES TO ATTICS TO R43, CRAWL SPACES <br />EQUAL THE WALL,FLOOR RATING. <br />a <br />THE GENERAL CONTRACTOR SHALL FULLY COMPLY WITH THE 2013 IRC AND ALL <br />ADDITIONAL STATE AND LOCAL CODE REQUIREMENTS. <br />2013 IEC, 2018 IMC AND 2013 IPC SHALL BE USED. <br />THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY WORK <br />KNOWINGLY PERFORMED CONTRARY TO SUCH LAWS, ORDINANCES, OR <br />REGULATIONS. THE CONTRACTOR SHALL ALSO PERFORM COORDINATION WITH <br />ALL UTILITIES AND STATE,COUNTY AND CITY AUTHORITIES. <br />THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND PROPER <br />FUNCTION OF PLUMBING, HVAC: AND ELECTRICAL SYSTEMS. THE GENERAL <br />CONTRACTOR SHALL NOTIFY THIS OFFICE WITH ANY PLAN CHANGES REQUIRED <br />FOR DESIGN AND FUNCTION OF PLUMBING, HVAC; AND ELECTRICAL SYSTEMS, <br />WILLIAM PAGE ARCHITECTS SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION <br />MEANS AND METHODS, ACTS OR OMISSIONS OF THE CONTRACTOR OR <br />SUBCONTRACTOR, OR FAILURE OF ANY OF THEM TO CARRY OUT WORK IN <br />ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS, AND DEFECT <br />DISCOVERED IN THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE <br />ATTENTION OF THIS OFFICE BY WRITTEN NOTICE BEFORE PROCEEDING WITH WORK. <br />REASONABLE TIME NOT ALLOWED THIS OFFICE TO CORRECT THE DEFECT SHALL <br />PLACE THE BURDEN OF COST AND LIABILITY FROM SUCH DEFECT UPON THE <br />CONTRACTOR. <br />THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE <br />PLANS BEFORE STARTING WORK, WORK NOT SPECIFICALLY DETAILED SHALL BE <br />CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL <br />WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES <br />AND LOCAL CODES, <br />SPECIAL INSPECTOR QUALIFICATIONS: DEMONSTRATE COMPETENCE, TO THE <br />SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR <br />TYPE OF CONSTRUCTION OR OPERATION IN QUESTION. PRIOR TO THE BEGINNING <br />OF CONSTRUCTION, REVIEW THE SPECIAL INSPECTION REQUIREMENTS WITH THE <br />ARCHITECT, ENGINEER, BUILDING OFFICIAL, GENERAL CONTRACTOR AND <br />SPECIAL INSPECTORS. <br />DUTIES OF THE SPECIAL INSPECTOR INCLUDE, BUT ARE NOT LIMITED TO: <br />OBSERVE THE WORK FOR CONFORMANCE WITH THE APPROVED PERMIT <br />DRAWINGS AND SPECIFICATIONS, BRING DISCREPANCIES TO THE IMMEDIATE <br />ATTENTION OF THE GENERAL CONTRACTOR FOR BUILDING OFFICIAL. <br />FURNISH INSPECTION REPORTS FOR EACH INSPECTION TO THE BUILDING OFFICIAL, <br />ARCHITECT, ENGINEER, GENERAL CONTRACTOR AND OWNER IN A TIMELY <br />MANNER. <br />SUBMIT A FINAL REPORT STATING WHETHER THE WORK REQUIRING SPECIAL <br />INSPECTION WAS INSPECTED, AND WHETHER THE WORK IS IN CONFORMANCE <br />WITH THE APPROVED PERMIT DRAWINGS AND SPECIFICATIONS, <br />DUTIES OF THE GENERAL CONTRACTOR INCLUDE, BUT ARE NOT LIMITED TO: <br />NOTIFY SPECIAL INSPECTOR THAT WORK IS READY FOR INSPECTION AT LEAST 24 <br />HOURS BEFORE THE INSPECTION IS REQUIRED. <br />MAINTAIN ACCESS TO WORK REQUIRING SPECIAL INSPECTION UNTIL IT HAS BEEN <br />OBSERVED AND INDICATED TO BE IN CONFORMANCE BY THE SPECIAL INSPECTOR <br />AND APPROVED BY THE BUILDING OFFICIAL. <br />PROVIDE THE SPECIAL INSPECTOR WITH ACCESS TO APPROVED PERMIT <br />DRAWINGS AND SPECIFICATIONS AT THE JOB SITE. <br />MAINTAIN JOB -SITE COPIES OF ALL REPORTS SUBMITTED BY THE SPECIAL <br />INSPECTOR. <br />DEFINITIONS: <br />CONTINUOUS INSPECTION: THE SPECIAL INSPECTOR IS OBSERVING THE WORK <br />REQUIRING SPECIAL INSPECTION AT ALL TIMES. <br />PERIODIC INSPECTION: THE SPECIAL INSPECTOR IS ON SITE AS REQUIRE© TO <br />CONFIRM THAT THE WORK REQUIRING SPECIAL INSPECTION IS IN <br />CONFORMANCE, <br />THIS STRUCTURE SHALL BE ADEQUATELY BRACED FOR WIND LOADS UNTIL THE <br />ROOF, FLOOR AND WALLS HAVE BEEN PERMANENTLY FRAMED TOGETHER AND <br />SHEATHED. <br />THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND <br />COORDINATION OF OTHER SUB CONTRACTORS TO SECURE COMPLIANCE OF <br />DRAWINGS AND SPECIFICATIONS AND THE ACCURATE LOCATION OF <br />STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL,ELECTRICAL,STAIRS <br />AND ALL OTHERS ITEMS. <br />CONTRACTOR SHALL NOTIFY OWNER,ARCHITECT AND LOCAL BUILDING <br />OFFICIALS AT CRITICAL MILESTONES AS ESTABLISHED BY LOCAL MUNICIPALITY <br />AND AS SHOWN IN THESE DOCUMENTS IN ORDER TO OBTAIN NECESSARY <br />APPROVALS PRIOR TO COMMENCEMENT OF FURTHER WORK. <br />MITI i '�E�AX <br />THE ARCHITECT IS NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY <br />PRECAUTIONS,MEANS,METHODS,TECHNIQUES,SEQUENCES OR <br />PROCEDURES. THE PERIODIC SITE VISITS BY THE ARCHITECT OR ENGINEER <br />SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION NOR <br />RESPONSIBLE FOR PROVIDING A SAFE PLACE FOR WORK BY THE <br />CONTRACTORS EMPLOYEES, OR EMPLOYEES OF SUPPLIERS OR <br />SUBCONTRACTORS,OR FOR ACCESS,VISITS,USE,WORK,TRAVEL, OR <br />OCCUPANCY BY ANY PERSON.THE CONTRACTOR SHALL TAKE ALL <br />REASONABLE PRECAUTIONS FOR THE SAFETY OF AND PROTECTION TO <br />PREVENT DAMAGEJNJURY OR LOSS TO: EMPLOYEES AND ALL OTHER <br />AFFECTED PERSONS,ALL WORK, AND MATERIALS AND EQUIPMENT, OTHER <br />PROPERTY( AT THE SITE OR ADJACENT PROPERTY. <br />HOMEOWNER WILL TAKE NECESSARY PRECAUTIONS TO REMOVE OR RELOCATE <br />ITEMS OF VALUE TO BE REUSED AND/ OR SAVED, OR IN ANY DANGER OF BEING <br />DAMAGED DUE TO CONSTRUCTION PROCESS. <br />THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF <br />WILLIAM PAGE ARCH ITFCTS,DEVELOPED FOR THE EXCLUSIVE USE OF WILLIAM <br />PAGE ARCHITECTS.USE OF THESE DRAWINGS AND CONCEPTS CONTAINED <br />THEREIN WITHOUT THE WRITTEN PERMISSION OF WILLIAM PAGE ARCHITECTS IS <br />PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR DAMAGES. <br />IT NDI <br />i <br />Seattle <br />Whidbey Island <br />PO. Box 665 Freeland <br />Washington 98249 <br />206-283-8317 <br />pagearchitects@grnail.com <br />www.williarnpagearchitect.com <br />Issue/Revisions <br />No. Gate Comments <br />RM <br />'v1LL 41 JA50 PAGE 11 <br />�XAIT, OF WWSHING TO <br />Copyright 2021 William Page Architects <br />General Notes <br />