My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5515 BEVERLY LN 2022-06-27
>
Address Records
>
BEVERLY LN
>
5515
>
5515 BEVERLY LN 2022-06-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2022 1:22:59 PM
Creation date
6/27/2022 1:22:43 PM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY LN
Street Number
5515
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6/7/2022 Page <br /> City of Everett <br /> 6:39:56AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E2103-003 Site Address 5515 BEVERLY LN <br /> Applied 3/1/2021 Applicant Martin Diko Lot <br /> Approved 3/1/2021 Owner Martin Diko Block <br /> Issued 3/1/2021 Contractor Martin Diko Tract <br /> Parent Permit No. B2006-029 Description ELECTRICAL ASSOCIATED WITH#B2006-029 <br /> Notes <br /> Scheduled Completed Tvne Inspector Result Remarks Inspector's Comments <br /> 3/2/2021 3/2/2021 ELEC 06-ROUGH SKB CORRECTION (3/2/2021 3:00 PM SKB) <br /> IN Finish nail plating.Provide a wall switch <br /> light and receptacle in the mechanical <br /> room.Provide an outside rear receptacle <br /> connect the water pipe electrode bond the <br /> gas pipe.complete all grounds.Ground <br /> metal box by panel.Add a wall switch <br /> controlled outside light at lower deck door. <br /> 3/5/2021 3/5/2021 ELEC 06-ROUGH SKB APPROVAL as noted 3/4/2021 5:37 PM Martin Diko <br /> IN Corrections all fixed.Requesting early <br /> morning if possible.Thank you <br /> Contact Name:Martin Diko <br /> Site Address:5515 BEVERLY LN <br /> Phone:4253467990 <br /> e-Mail:martindiko@live.com <br /> (3/5/2021 11:26 AM SKB) <br /> Check AFCI and GFCI at final and verify <br /> water grounding electrode size. <br /> 7/9/2021 7/9/2021 PERMIT KLC EXTENSION A COVID <br /> EXTENSION EXTENSION , <br /> 6/1/2022 6/1/2022 ELEC 10-FINAL SKB CORRECTION (5/27/2022 1:48 PM JSG) <br /> 425-346-7990 <br /> MARTINDIKO@LIVE.COM <br /> (6/1/2022 12:46 PM SKB) <br /> Install a continuous duty extra duty wet <br /> rated cover on the back deck receptacle. <br /> All outside receptacles must be wet rated <br /> and GFCI protected.You cannot have an <br /> LED light above the shelf in the bedroom <br /> closet.Mirrors in the bathroom cannot be <br /> on the receptacle circuit.Find GFCI <br /> protection for the dryer.Provide AFCI <br /> protection for all required circuits such as <br /> kitchen chandelier etc.per 210.12. <br /> 6/6/2022 6/6/2022 ELEC 10-FINAL SKB APPRVD-PERK As noted 6/4/2022 9:15 PM Martin Diko <br /> Contact Name:Martin Diko <br /> Site Address:5515 BEVERLY LN <br /> Phone:4253467990 <br /> e-Mail:martindiko@live.com <br /> (6/6/2022 1:48 PM SKB) <br /> Owner installing last AFCI breaker required <br /> for bedroom lights <br /> INSP12 C'll WSYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.