Laserfiche WebLink
_ , <br /> P POTTER PSN SERIES <br /> ® The Symbol of Protection POWER SUPPLY <br /> PSN-106 Wiring Diagram <br /> 4° 120/240 VAC GND FAULT <br /> o Jumper Position DETECT ENABLE <br /> ON III oI OFF <br /> I20VAC 50Hz-60Hz <br /> 240VAC 50Hz-60Hz Black <br /> Connect to separate White <br /> unswitched AC circuit Ground - status LED's <br /> AllikkA LEI N4•CI NAC•2 NAC•3 NAC•4 NAC•S NAC•6 DCPWR <br /> • <br /> s, 3 SS <br /> pugpima'=== <br /> H NA ❑ o o I898�9., <br /> 0 0 Fuse ll� .,„.s!:ll},' <br /> [ 31� -- I,• <br /> o � 1 !I, . , I o� o liae»sse�; <br /> o D I ]i1VA� l e I <br /> Factory Installed <br /> Interconnect. <br /> AC Power o I399999},' <br /> Low Battery O <br /> cud Fault I I f ii8889 <br /> cn� l o <br /> H o <br /> YfrOY <br /> 8 <br /> Bulk Options <br /> .° <br /> 784-77 <br /> r3' ll1�uI�ICIOIc Wit (] (] NA('1 NAC2 NAdI N\C4 CS NAC6 DC MR RI:} NI LV2 0 <br /> -NC COMrNO NC COM NO t — I ! II I <br /> Common relays are I:0°`O <br /> 0666641 F_O.L <br /> non-power limited. — t;I.' <br /> RO L <br /> _ DC Power Trigger <br /> tir <br /> ...6.,...; <br /> Batten connection Innn-pow c switol: Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power <br /> Use two(2)12V battenes connected in series. supply is triggered.There is no current draw in Standby Mode. <br /> Engineering Specification <br /> The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further <br /> power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble <br /> shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed <br /> the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. <br /> housing up to 18 AH batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps ofcontinuous <br /> up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for <br /> The panel shall have dip switches for simplistic configuration of the multiple circuits ofstrobe appliances.The power supply shall synchronize <br /> system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit <br /> ofthe system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of <br /> Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to <br /> auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above <br /> Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and <br /> Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. <br /> of communication between the power supply and distribution circuit <br /> PRINTED IN USA MKT.#8910013-REV D PAGE 2 OF 2 <br /> 1/18 <br /> 4 \ S <br />