Laserfiche WebLink
S <br /> Alterations Worksheet 2015 Washington State Energy Code <br /> Pa'jectlnfoimatlon Contactlnfonnution <br /> BakerAdaiiic l - .. . "NuttyCAD`Drafting;and-Design;LLC' " <br /> 1410 119tfi.Place S.E. (206)225-0068 <br /> ,Everett,-WA-98208 ,. <br /> The Washington State Energy Code requirements for alterations are located in Chapter 5 <br /> Alterations(remodels)do not need to obtain energy credits from Table R406.2 <br /> Additions must meet the requirements for new construction. This includes nonconditioned space being <br /> altered to become conditioned space. <br /> Will the wall cavities be exposed? r Yes >✓ No <br /> If yes: Exposed wall cavities must be insulated- <br /> 2 X 4 wall studs require R-15 insulation <br /> 2 X 6 wall studs require R-21 insulation <br /> Will the roof/ceiling framing cavities or attic be exposed? w Yes r No <br /> If yes: Exposed roof/ceiling assemblies must be insulated- <br /> Vaulted ceilings: Insulate to the full depth of the framing member <br /> while allowing for the minimum 1"ventilated space <br /> Flat ceilings: Install R-49 insulation or what the attic space can <br /> accommodate based on the roof pitch <br /> Will the floor framing cavities be exposed? r Yes l No <br /> If yes: Exposed floor cavities must be insulated to R-30 <br /> Are the windows and/or doors being replaced? R7 Yes E No <br /> (includes both window or door and frames) <br /> If yes: New windows and doors must have an area weighted average U-factor of s0.30 <br /> Will the heating or cooling system be replaced? r Yes f No <br /> If yes: New equipment must meet current requirements and <br /> ducts need to be tested <br /> Will the hot water system be altered? r Yes 14 No <br /> If yes: New water heating equipment must meet current code requirements <br /> Are more than 50%of the light fixtures being changed? Ri Yes r No <br /> If yes: 75% of all lamps must be high efficacy <br /> (LED or CFL) <br /> R503.1.1 Building envelope.Building envelope assemblies that are part of the alteration shall comply with Section R402.1.1 or R402.1.4, <br /> Sections R402.2.1 through R402.2.11,R402.3.1,R402.3.2,R402.4.3 and R402.4.4. <br /> Exception:The following alterations need not comply with the requirements for new construction provided the energy use of <br /> the building is not increased: <br /> 1. Stoner windows installed over existing fenestration. <br /> 2. Existing ceiling,wall or floor cavities exposed during construction provided that these cavities are filled with <br /> insulation.2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a minimum <br /> ofR21. <br /> 3. Construction where the existing roof,wall or floor cavity is not exposed. <br /> 4. Roof recover. • <br /> 5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulates <br /> either above or below the sheathing. <br /> 6. Surface-applied window film installed on existing single pane fenestration assemblies to reduce solar heat gain provided <br /> the code does not require the glazing fenestration to be replaced <br /> R503.1.1.1 Replacement fenestration.Where some or all of an existing fenestration unit is replaced with a new fenestration product, <br /> including sash and glazing,the replacement fenestration unit shall meet the applicable requirements forU-factor and SHGC in Table <br /> R402.1.1. <br /> R502.1.L2 Heating and cooling systems.New heating,cooling and duct systems that are part of the addition shall comply with Sections <br /> R403.1,R403.2,R403.3,R403.5 and R403.6. <br /> Exception:The following need not comply with the testing requirements of Section R403.3.3: <br /> 1. Additions of less than 750 square feet. <br /> 2. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic <br /> testing in accordance with procedures in WSU RS-33. <br /> 3. Ducts with less than 40 linear feet in unconditioned spaces. <br /> 4. Existing duct systems constructed,insulated or sealed with asbestos. • <br /> R503.1.3 Service hot water systems.New service hot water systems that are part of the alteration shall comply with Section R403.4. <br /> R503.1.4 Lighting.New lighting systems that are part of the alteration shall comply with Section R404.1. <br /> Exception:Alterations that replace less than 50 percent of the luminaires in a space,provided that such alterations do not <br /> increase the installed interior lighting power. <br /> R503.2 Change in space conditioning.Any nonconditioned or low-energy space that is altered to becomeconditioned space shall be <br /> required to be brought into full compliance with this code. <br />