Laserfiche WebLink
Ih Job truss Truss Type Qty Ply CHRISTOPHER CONST/FRANKLIN ADU <br /> 2106757 GE01 Common Supported Gable 1 1 <br /> Job Reference(optional) <br /> Louws Truss,Inc.,Ferndale,WA 98248 Run:8.520 s Oct 22 2021 Print 8.520 s Oct 22 2021 MiTek Industries,Inc. Mon Dec 6 08:31:25 2021 Pag 1 <br /> I✓ ID:eDkaF21f8kk9pyQLxANYDmyBjCE-hW26fVN6WAEloDlUthgQcw49yjiS7aJOz3MjTKyBjo <br /> -2-0-0 6-0-0 i 12-0-0 14-0-0 <br /> 2-0-0 6-0-0 6-0-0 2-0-0 <br /> 6 <br /> 5.00 12 5 7 Scale=1:31. <br /> P 8 <br /> 1.1 <br /> li <br /> li <br /> ST1 4 01 to 21ST1 <br /> M : 19 3 20 � I 9 22 <br /> 10 <br /> 2 'l •Id' 0 .!u ' <br /> I <br /> :':it:l:':':2:il:l:l:l:l:l:l:l:l:!i i!:!:!:l:l:il:!:!:!:!:!:!:!:!:!:!:lJ:il:l:l:l!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!:!i 11 <br /> 3x4= 18 17 16 15 14 13 12 3x4= <br /> I 12-0-0 I <br /> 12-0-0 <br /> LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.24 Vert(LL) -0.02 11 n/r 120 MT20 220/195 <br /> TCDL 7.0 Lumber DOL 1.15 BC 0.12 Vert(CT) -0.03 11 n/r 90 <br /> BCLL 0.0 * Rep Stress lncr YES WB 0.01 Horz(CT) 0.00 10 n/a n/a <br /> BCDL 8.0 Code IRC2015/TP12014 Matrix-RH Weight:53 lb FT=10% <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 DF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. <br /> BOT CHORD 2x4 DF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> OTHERS 2x4 DF No.2 MiTek recommends that Stabilizers and required cross bracing <br /> be installed during truss erection,in accordance with Stabilizer <br /> Installation guide. <br /> REACTIONS. All bearings 12-0-0. <br /> (Ib)- Max Horz 2=-54(LC 13) <br /> Max Uplift All uplift 100 lb or less at joint(s)16,17,18,14,13,12 except 2=-117(LC 8),10=-121(LC 9) <br /> Max Gray All reactions 250 lb or less at joint(s)15,16,17,18,14,13,12 except 2=278(LC 1),10=278(LC 1) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> NOTES- <br /> 1)Unbalanced roof live loads have been considered for this design. <br /> 2)Wind:ASCE 7-10;Vult=110mph Vasd=87mph;TCDL=4.2psf;BCDL=3.0psf;h=25ft;Cat.II;Exp C;Enclosed;MWFRS(envelope)gable <br /> end zone and C-C Corner(3)-2-0-0 to 1-7-3,Exterior(2)1-7-3 to 6-0-0,Corner(3)6-0-0 to 9-7-3,Exterior(2)9-7-3 to 14-0-0 zone; <br /> cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces&MWFRS for reactions shown; <br /> Lumber DOL=1.60 plate grip DOL=1.60 <br /> 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry <br /> Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. <br /> 4)All plates are 1.5x4 MT20 unless otherwise indicated. <br /> 5)Plates checked for a plus or minus 15 degree rotation about its center. <br /> 6)Gable requires continuous bottom chord bearing. <br /> 7)Gable studs spaced at 1-4-0 oc. <br /> 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 9)*This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit <br /> between the bottom chord and any other members. <br /> 10)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)16, 17,18,14,13,12 <br /> except(jt=lb)2=117,10=121. <br /> 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced <br /> standard ANSI/TPI 1. <br /> LOAD CASE(S)Standard <br />