706 32ND ST 2021 Plans 2023-03-31
>
Address Records
>
32ND ST
>
706
>
Plans
>
706 32ND ST 2021 Plans 2023-03-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2023 10:06:25 AM
Creation date
7/18/2022 1:16:19 PM
Metadata
Fields
Template:
Address Document
Street Name
32ND ST
Street Number
706
Permit
B2111-025
Year
2021
Notes
CONSTRUCT NEW 616 SQ FT DADU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"I <br />ENERGY CODE COMPLIANCE: <br />Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel <br />normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of <br />credits. To claim this credit, the building permit drawings shall specify the option selected and the maximurr <br />tested building air leakage, and show the qualifying ventilation system and its control sequence of <br />operation. <br />1. Small Dwelling Unit: 3 credits <br />Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. <br />Additions to existing building that area greater than 500 sf of heated floor area but less than 1,500 sf. <br />2. Medium Dwelling Unit: 6 credits <br />All dwelling units that are not included in #1 or #3 <br />3. Large Dwelling Unit: 7 credits <br />Dwelling units exceeding 5,000 sf of conditioned floor area <br />4. Additions less than 500 square feet: 1.5 credits <br />All other additions shall meet 1-3 above <br />Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. <br />Summary of Table R406.2 <br />Heating <br />Fuel Normalization Descriptions <br />Credits - Select ONEOptions <br />heating option <br />User Notes: <br />1 <br />Combustion heating minimum NAECA b <br />0.0 ❑ <br />2 <br />Heat pump c <br />1.0 ❑ <br />3 <br />Electric resistance heat only - furnace or zonal <br />-1.0 ❑ <br />4 <br />DHP with zonal electric resistance per option 3.4 <br />0.5 ■ <br />5 <br />All other heating systems <br />-1.0 0 <br />Energy <br />Options <br />Energy Credit Option Descriptions <br />Credits - Select ONE <br />energy option from each <br />category <br />User Notes: <br />1.1 <br />Efficient Building Envelope <br />0.5 ■ <br />1.2 <br />Efficient Building Envelope <br />1.0 ❑ <br />1.3 <br />Efficient Building Envelope <br />0.5 <br />1.4 <br />Efficient Building Envelope <br />1.0 ❑ <br />1.5 <br />Efficient Building Envelope <br />2.0 ❑ <br />1.6 <br />Efficient Building Envelope <br />3.0 ❑ <br />1.7 <br />Efficient Building Envelope <br />0.5 ❑ <br />2.1 <br />Air Leakage Control and Efficient Ventilation <br />0.5 ❑ <br />2,2 <br />Air Leakage Control and Efficient Ventilation <br />1.0 ❑ <br />2.3 <br />Air Leakage Control and Efficient Ventilation <br />1.5 ❑ <br />2.4 <br />Air Leakage Control and Efficient Ventilation <br />2.0 ❑ <br />3.1a <br />High Efficiency HVAC <br />1.0 ❑ <br />3.2 <br />High Efficiency HVAC <br />1.0 ❑ <br />3.3a <br />High Efficiency HVAC <br />1.5 ❑ <br />3.4 <br />High Efficiency HVAC <br />1.5 ■ <br />3.5 <br />High Efficiency HVAC <br />1.5 ❑ <br />3.6a <br />High Efficiency HVAC <br />2.0 ❑ <br />4.1 <br />High Efficiency HVAC Distribution System <br />0.5 ❑ <br />4.2 <br />High Efficiency HVAC Distribution System <br />1.0 ❑ <br />5,111 <br />Efficient Water Heating <br />0.5 ❑ <br />5.2 <br />Efficient Water Heating <br />0.5 ❑ <br />5.3 <br />Efficient Water Heating <br />1.0 ❑ <br />5.4 <br />Efficient Water Heating <br />1.5 ❑ <br />5.5 <br />Efficient Water Heating <br />2.0 ❑ <br />5.6 <br />Efficient Water Heating <br />2.5 ❑ <br />6.1e <br />Renewable Electric Energy (3 credits max) <br />1.0 ❑ <br />7.1 <br />Appliance Package <br />0.5 ■ <br />Total Credits <br />3.0 <br />a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or <br />500 W, whichever is bigger, may be installed in the dwelling unit. <br />b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) <br />c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) <br />d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may <br />be combined with options 5.2 through 5.6. See Table 406.3. <br />e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. <br />See the complete Table R406.2 for all requirements and option descriptions. <br />IF THIS PLAN IS NOT ON 18x24 PAPER, IT HAS BEEN SCALED ACCORDINGLY <br />Window, Skylight and Door Schedule <br />Project information Contact Information <br />Franklyn DADU Nutt CAD Drafing & Design, LLC <br />206 225-0068 <br />Width Height <br />Ref. U-factor Qt. Feet inch Feet inch Area UA <br />Exempt Swinging Door (24 sq. ft. max.) 1101 10.42 1 1 20.08.40 <br />Exempt Glazed Fenestration (15 sq. fit. max.) C 124 1 =MOMS 1 15-01 3.60 <br />Description <br />Ref. <br />U-factor <br />Qt. <br />Feet <br />Inch Feet <br />Inch <br />Area <br />UA <br />ture Window <br />A <br />024 <br />' <br />2 - <br />0 22 <br />0 <br />4.0 <br />0. <br />XO Slider <br />8 <br />0.24 <br />2 <br />- <br />4 <br />2 <br />16.0 <br />3. <br />in le Hung <br />C <br />0.24 <br />1 <br />3 <br />° 5 <br />° <br />15.0 <br />3. <br />,in le Hung <br />0.24 <br />1 <br />2 <br />° 3 <br />° <br />6.0 <br />1. <br />XO Slider <br />E <br />0.24 <br />1 <br />4 <br />° 3 <br />6 <br />14.0 <br />3. <br />XO Slider <br />F <br />024 <br />1 <br />5 <br />a 4 <br />20.0 <br />4. <br />XO Slider <br />G <br />0.24 <br />1 <br />4 <br />° 4 <br />0 <br />16.01 <br />3. <br />Entry Door 1101 10.42 <br />French Door 1103 10.24 <br />Overhead Glazing (Skylights) <br />Component <br />Sum of Vertical Fenestration Area and UA <br />Vertical Fenestration Area Weighted U = UA/Area <br />Width Height <br />Feet inch Feet Inch <br />Sum of Overhead Glazing Area and UA <br />Overhead Glazing Area Weighted U = UA/Area <br />Total Sum of Fenestration Area and UA (tor heating system sizing calculations) <br />1 1 <br />1 1 <br />1 I1 <br />11 <br />111 <br />11 <br />111 <br />li <br />1i1 <br />11 <br />111 <br />11 <br />111 <br />1 1 <br />1 11 <br />1/ <br />1/1 <br />I f <br />1 m <br />1 1 <br />f 11 <br />11 <br />11! <br />1 1 <br />I tl <br />11 <br />111 <br />11 <br />1 11 <br />Area UA <br />Simple Heating System Size: Washington State <br />This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals <br />J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br />Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some <br />values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at <br />energycode@energy.wsu.edu or (360) 956-2042 for assistance. <br />225-0068 <br />All Other systems 0 Heat Pump <br />To see detailed instructions for each section, place your cursor on the word "Instructions" <br />Design Temperature <br />Instructions Design Temperature Difference (AT) 49 <br />Everett Paine Al~6 _ • <br />> AT =Indoor (70 degrees) - Outdoor Design Temp <br />Area of Building <br />Conditioned Floor Area <br />Instructions Conditioned Floor Area (sq ft) S16 <br />Average Ceiling Height Conditioned Volume <br />Instructions Average Ceiling Height (ft) 9.0 5,5444 <br />Glazing and Doors U-Factor X Area UA <br />Instructions _ <br />ti-0.24 . 0,240 "�#� 44.64 <br />Skylights U-Factor X Area = UA <br />Instructions, 0.50 -- <br />Insulation <br />Attie U-Factor X Area = UA <br />Instructions <br />R-49 0.026 16.02 <br />Single Rafter or Joist Vaulted Collins U-Factor X Area UA <br />Instructions s -V Rn <br />select -Value . No selection --- <br />Above Grade Walls (-Figure 1) U-Factor X Area UA <br />Instructions R-29 tntee0.056 1,080 60.48 <br />rmciiate ; • <br />Floors U-Factor X Area UA <br />instructions ip <br />Select R-value „ No selection -- <br />Below Grade Walls /see Figure 1) U-Factor X Area UA <br />Instructions rxraa ab u"w.�` <br />yew R-val a No selection -- <br />Slab Below Grade see Fr ure F-Factor X Length UA <br />Irlstruction5 I Y i�Y4't�f:YWIuiYiwat " '` .55m4da LLa&.u.G„ 7@11� r'�"� <br />Selectcondkianin9 ♦ No selection IL�_JI <br />Slab on Grade tse® Figure t F-Factor X Length UA <br />instructions 0.360 120 43.20 <br />x-to Fully Insulated <br />Location of Ducts <br />Instructions Duct Leakage Coefficient <br />NO t){icts + <br />1.00 <br />Sum of UA 164.34 <br />Envelope Heat Load 8,052 Btu / Hour <br />Figure 1. Sum of UA x AT <br />Air Leakage Heat Load 2,934 Btu / Hour <br />Volume x 0.6 x AT x 0.018 <br />Building Design Heat Load 10,986 Btu / Hour <br />Air leakage + envelope heat foss <br />" Bu€iding and Duct Heat toad 10,986 Btu / Hour <br />Ducts in unconditioned space: sum of building heat loss x I.10 <br />Ducts in conditioned space: sum of building heat loss x 1 <br />Maximum Heat Equipment Output 15,381 Btu / Hour <br />Building and duct heat loss x 1.40 for forced air furnace <br />Building and duct heat loss x 1.25 for heat pump <br />TY O v R <br />REVIEWED FORPERMIT' <br />x <br />J a <br />(D <br />0 <br />� <br />00 <br />0000 <br />a <br />Wa <br />wrn <br />>Q <br />Ln <br />E� <br />U ®� <br />t <br />ioo <br />m <br />U_�Z <br />z o <br />rn <br />E <br />00 <br />CD 0 <br />CDU <br />LL� <br />m-C <br />o <br />0 <br />r; <br />x <br />® ¢ <br />V) <br />N <br />N <br />� <br />0 <br />A <br />N <br />Ln <br />� r- r` <br />O a) m vo <br />z�cc C) <br />0 m V <br />N <br />-C } N = <br />N ((1 t V <br />Y � J <br />O � <br />� J <br />1✓ <br />w <br />ID <br />0 <br />u <br />0 <br />V <br />a <br />V <br />cv <br />00 <br />� <br />�� <br />O <br />�i <br />N <br />0 <br />C: <br />CVLn <br />-E <br />1..1� <br />CD <br />W <br />r. <br />Q) <br />7 <br />w <br />i` <br />0 <br />M <br />0 <br />=- <br />o <br />LL. <br />rn <br />Lo <br />Ln <br />0 <br />0 <br />0 <br />z <br />a <br />Plan Title <br />Energy Code <br />Douglas Almond <br />Original Drawn Date <br />11/03/2021 <br />21-049-01 <br />Plan Revisions <br />O - <br />05/11/2022 <br />0 - <br />Sheet: <br />we* <br />1 1 WSEC 2018 J <br />o, - <br />