4429 SEAHURST AVE 2022 Plans 2022-11-08
>
Address Records
>
SEAHURST AVE
>
4429
>
Plans
>
4429 SEAHURST AVE 2022 Plans 2022-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 10:15:18 AM
Creation date
7/18/2022 1:59:15 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAHURST AVE
Street Number
4429
Permit
B2204-068
Year
2022
Notes
597SF UPPER FLOOR DECK ADDITION TO EXTG SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED UFFER FLOOR PECK PLAN I I I I <br />24x3& SCALE 1/4' = 1'-01, 0 1 2 9 4 <br />M <br />FLOOR PLAN LEGEND <br />EXISTING MALL TO REMAIN <br />r INDICATES NO WORK AREA <br />NEC ARTICLE 210(E)(3): BALCONIES, DECKS, AND PORCHES. BALCONIES, DECKS, AND PORCHES THAT <br />ARE ACESSIBLE FROM INSIDE THE DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET <br />INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL NOT <br />BE LOCATED MORE THAN 6 t/2 FT ABOVE THE BALCONY, DECK, OR PORCH SURFACE. <br />R303o6®EXTERIOR STAIRWAY ILLUMINATION: EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN <br />ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY, EXTERIOR STAIRWAYS <br />PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN <br />ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. <br />R311.7.5.1-RISERS: THE RISER HEIGHT SHALL BE NOT MORE THAN 7 % INCHES (196 MM). THE RISER <br />SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE <br />GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE <br />THAN 3l6 INCH (9,5 MM). RISERS SHALL BE VERT ICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING <br />OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. OPEN <br />RISERS ARE PERMITTED PROVIDED THAT THE OPENINGS LOCATED NOT MORE THAN 30 INCHES (762 MM), <br />AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A <br />4-INCH-DIAMETER (102 MM) SPHERE. SEE EXCEPTIONS. <br />All drawings and written material appearing herei <br />constitute original and unpublished work of the <br />designer and may not be duplicated, used or <br />disclosed without written consent of the designer. <br />REVISIONS <br />Drawn By: <br />Checked By: <br />Job #: <br />co <br />R31115.2-TREADS DEPTH: THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD <br />DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST <br />PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE <br />Uj <br />W <br />GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE <br />W <br />THAN 318 INCH (9.5 MM). SEE EXCEPTIONS. <br />W <br />R312.1 GUARDS: INHERE REQUIRED, GUARDS SHALL BE LOCATED ALONG OPEN -SIDED WALKING <br />U) <br />SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN 30 INCHES (762 <br />MM) MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 <br />MM) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED <br />4�1 <br />AS A GUARD. <br />R312.1.2 HEIGHT. REQUIRED GUARDS AT OPEN=SIDED WALKING SURFACES, INCLUDING STAIRS, <br />PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS <br />MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE, OR THE LINE CONNECTING THE <br />LEADING EDGES OF THE TREADS, SEE EXCEPTIONS, <br />R312.1.3 OPENING LIMITATIONS. REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING <br />SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4-INCHES (102 MM) IN <br />4'-0 o MAX SPACING <br />I® V-OIL MAX SPACING <br />DIAMETER. SEE EXCEPTIONS. <br />BETWEEN POSTS <br />BETWEEN POSTS <br />Lid <br />06 <br />TOP RAIL MUST RESI <br />200# CONCE T RATED <br />LOAD PER MFR. OR <br />PROVIDE (4)16d NAILS <br />EA POST <br />OPENINGS SHALL NOT <br />ALLOW THE PASSAGE <br />01 <br />CABLES SHALL BE <br />SPACED 3"o/c <br />OF A 4"0 SPHERE <br />GU RADRAIL PREVENTING A 30" FALL OR MORE <br />X <br />0 <br />to®B®a®aBg <br />X <br />co <br />Approval Stamp <br />DESCRIPTION OF <br />TYP. GUARDRAIL <br />SCALE. V= -0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.