Laserfiche WebLink
PROPOSED UFFER FLOOR PECK PLAN I I I I <br />24x3& SCALE 1/4' = 1'-01, 0 1 2 9 4 <br />M <br />FLOOR PLAN LEGEND <br />EXISTING MALL TO REMAIN <br />r INDICATES NO WORK AREA <br />NEC ARTICLE 210(E)(3): BALCONIES, DECKS, AND PORCHES. BALCONIES, DECKS, AND PORCHES THAT <br />ARE ACESSIBLE FROM INSIDE THE DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET <br />INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL NOT <br />BE LOCATED MORE THAN 6 t/2 FT ABOVE THE BALCONY, DECK, OR PORCH SURFACE. <br />R303o6®EXTERIOR STAIRWAY ILLUMINATION: EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN <br />ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY, EXTERIOR STAIRWAYS <br />PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN <br />ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. <br />R311.7.5.1-RISERS: THE RISER HEIGHT SHALL BE NOT MORE THAN 7 % INCHES (196 MM). THE RISER <br />SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE <br />GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE <br />THAN 3l6 INCH (9,5 MM). RISERS SHALL BE VERT ICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING <br />OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. OPEN <br />RISERS ARE PERMITTED PROVIDED THAT THE OPENINGS LOCATED NOT MORE THAN 30 INCHES (762 MM), <br />AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A <br />4-INCH-DIAMETER (102 MM) SPHERE. SEE EXCEPTIONS. <br />All drawings and written material appearing herei <br />constitute original and unpublished work of the <br />designer and may not be duplicated, used or <br />disclosed without written consent of the designer. <br />REVISIONS <br />Drawn By: <br />Checked By: <br />Job #: <br />co <br />R31115.2-TREADS DEPTH: THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD <br />DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST <br />PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE <br />Uj <br />W <br />GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE <br />W <br />THAN 318 INCH (9.5 MM). SEE EXCEPTIONS. <br />W <br />R312.1 GUARDS: INHERE REQUIRED, GUARDS SHALL BE LOCATED ALONG OPEN -SIDED WALKING <br />U) <br />SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN 30 INCHES (762 <br />MM) MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 <br />MM) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED <br />4�1 <br />AS A GUARD. <br />R312.1.2 HEIGHT. REQUIRED GUARDS AT OPEN=SIDED WALKING SURFACES, INCLUDING STAIRS, <br />PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS <br />MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE, OR THE LINE CONNECTING THE <br />LEADING EDGES OF THE TREADS, SEE EXCEPTIONS, <br />R312.1.3 OPENING LIMITATIONS. REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING <br />SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4-INCHES (102 MM) IN <br />4'-0 o MAX SPACING <br />I® V-OIL MAX SPACING <br />DIAMETER. SEE EXCEPTIONS. <br />BETWEEN POSTS <br />BETWEEN POSTS <br />Lid <br />06 <br />TOP RAIL MUST RESI <br />200# CONCE T RATED <br />LOAD PER MFR. OR <br />PROVIDE (4)16d NAILS <br />EA POST <br />OPENINGS SHALL NOT <br />ALLOW THE PASSAGE <br />01 <br />CABLES SHALL BE <br />SPACED 3"o/c <br />OF A 4"0 SPHERE <br />GU RADRAIL PREVENTING A 30" FALL OR MORE <br />X <br />0 <br />to®B®a®aBg <br />X <br />co <br />Approval Stamp <br />DESCRIPTION OF <br />TYP. GUARDRAIL <br />SCALE. V= -0" <br />