• • <br /> Simple Heating System Size:Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Davis ADU Neil Jorgensen <br /> 10708 Holly Dr 13 Architects LLC <br /> Everett WA 98204 425-242-0369 <br /> Heating System Type: ()All Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> .aions Design Temperature Difference(AT) 49 <br /> Everett Paine-AF8- v AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 568 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.4 4,771 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 81 24.30 <br /> Skylights U-Factor X Area = UA <br /> 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Select R-yams .j: No selection 1,098 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions 0.027 568 15.34 <br /> R-38 Vented <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.056 <br /> R-21Intermediate <br /> Floors U-Factor X Area UA <br /> Instructions - - -- <br /> R-30 . 0.029 568 16.47 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> •:Istructions ---No Below Grade Walls in this project --- <br /> Slab Below Grade(see Figure n F-Factor X Length UA <br /> nstructions <br /> No Slab Below Grade in this project V --- <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> 'nstruction, <br /> No Slab on Grade in this project V --- <br /> Location of Ducts <br /> Instruction- Duct Leakage Coefficient <br /> llecoedhioned Space � <br /> 1.10 <br /> Sum of UA 56.11 <br /> Envelope Heat Load 2,749 Btu/Hour <br /> Figure 1. Sum ofUAX AT <br /> Air Leakage Heat Load 2,525 Btu/Hour <br /> Volume X 0.6 X AT X.018 <br /> Above Grade Building Design Heat Load 5,274 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> "r Building and Duct Heat Load 5,802 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 8,122 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />