Laserfiche WebLink
S <br />'0,900J 9p� <br />8� Sys <br />2S2ocTq�, <br />�S <br />CB T-2 RIM=548.12' <br />IE=542.49' (30 CONC E) <br />IE=542.57' (30" CONC W) <br />SDMH RIM=548.55' <br />30" CONC N,S IN <br />30" CONC W OUT <br />/ IE CTR CHNL=540.90' <br />CB T- I RIM=547.81 ' <br />/ IE=544.86' (12" PVC N) <br />IE=544.86' (12" PVC S) Mgr <br />IE=544.86' (12" PVC E) <br />r <br />r <br />POWEVA U <br />/ <br />/ ~� S0 <br />i <br />W _ <br />BAI / <br />rnnnrn DE -DAD D. /`AD <br />RIM=546.2I ' <br />IE=542,81' (78" CONC S) <br />COULD NOT LOCAT OTHER END <br />Know whafs below. <br />Call before you dig. <br />UTILITYCONFLICTNOTL:- <br />CATION• - ----- -- <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, <br />DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE <br />PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL <br />AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE <br />CALLING UTILITY LOCATE ® 1-800-424-5555 POTHOLING ALL OF THE EXISTING <br />UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY <br />WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN <br />ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND <br />ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR <br />SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL <br />PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />/ S W 1/4, NW 114, SEC 24, T.24N., R.04E., W.M. <br />SNOHOMISH COUNTY, WASHINGTON <br />1 SDMH T-2 <br />RIM 0' <br />IE=543�43.95 95' (30" CONC N & S) <br />6) <br />6) / <br />1 , / CB T-1 RIM=550.16' <br />IE=547.57' (S) <br />POWER <br />VAULT SDMH T-2 <br />/ RIM=550.14' <br />IE=543.14' (30" CONC N & S) <br />IE=546.29' (8" PVC NW) <br />ti �IE=546.29' (12" PVC W) \ <br />'4 <br />SETBACK <br />26'_0 " <br />28'--0 " <br />F <br />4� <br />�a �r <br />28' I < <br />D <br />C�ULD N( <br />0 <br />CB T \ C <br />RIM= <br />IEo .73 (24" <br />IEzE 8' (24" <br />F W 6„ <br />W <br />4=5 0. <br />UN NOW <br />1 <br />Ssa <br />163'_3» <br />�1 Q� EQ, ASE <br />CB#2 ` <br />TYPE-1 <br />RIM: 550.80 <br />IE: 546.74 (NW E) <br />PER COE STD DWG #404 <br />6" CONC WALL <br />W/6' CHAINLINK FENCE <br />W/BARB WIRE TOP <br />L 2" COMPACTED DEPTH CLASS B ASPHALT <br />_- 4" COMPACTED DEPTH CR. SURFACE----_ <br />TOP COURSE <br />6" COMPACTED DEPTH GRAVEL BORROW <br />1 TYPICAL PA VING SECTION <br />NOT TB SCAM -REF CIIISTD 3=5-.2- - - - - - - -- <br />q�N411vk FENCE S54 <br />TACK \ \ VVIKL iur <br />"KNA 11033" \ <br />\ 15' WATER EASEMENT <br />AF#9007060231 <br />1 <br />2-__-PERFORM <br />763NOT TO SCALE <br />Tn9)Cn11 nip m/ r <br />I <br />WATER MAIN SYSTEM CONSTR UCTION NOTES: <br />1. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE DEVELOPER SHALL ARRANGE A PRE -CONSTRUCTION <br />CONFERENCE WITH THE MUKILTEO WATER DISTRICT. THE DEVELOPER AND PROPOSED ON -SITE <br />SUPERVISORS SHALL ATTEND. <br />2. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST REVISION, INCLUDING <br />-- ADDENDA AND UPDATES, OF THE MUKILTEO WATER DISTRICT DEVELOPER STANDARDS. CONTRACTOR TO <br />HAVE MUKILTEO WATER DISTRICT STANDARDS ON JOB SITE. <br />3. AN APPROVED AND DISTRICT SIGNED COPY OF THESE PLANS MUST BE ON THE JOB SITE WHENEVER <br />CONSTRUCTION IS IN PROGRESS <br />4. ALL WATER SYSTEM IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THESE APPROVED <br />PLANS. ANY DEVIATION FROM THE PLANS WILL REQUIRE APPROVAL FROM THE OWNER, ENGINEER, <br />DISTRICT AND APPROPRIATE PUBLIC AGENCIES. <br />5. NOTIFY THE DISTRICT 72 HOURS (3 WORKING DAYS) PRIOR TO BEGINNING CONSTRUCTION AND FOR <br />ANY RESTARTS OF WORK. <br />I 6. THE DISTRICT SHALL BE NOTIFIED THREE WORKING DAYS PRIOR TO THE TIME THE DEVELOPER WOULD <br />LIKE TO CONNECT TO EXISTING MAINS OR FOR INSTALLATION OF TAPPING TEES. THE CONNECTION <br />SHALL BE DONE IN ACCORDANCE WITH DISTRICT REQUIREMENTS. DEVELOPER SHALL NOT OPERATE <br />SCALE. 1 vo = 30' ANY DISTRICT VALVES; THESE WILL BE OPERATED BY WATER DISTRICT PERSONNEL ONLY. <br />7. FOR AID IN UTILITY LOCATION, CALL 1-800-424-5555, A MINIMUM OF 48 HOURS (2 WORKING <br />DAYS) PRIOR TO BEGINNING OF CONSTRUCTION. EXISTING UTILITIES, WHETHER SHOWN OR NOT, SHALL <br />I 30' 15' 0 30' 60' BE LOCATED PRIOR TO CONSTRUCTION, SO AS TO AVOID DAMAGE OR DISTURBANCE, AND THE <br />DEVELOPER SHALL ASSUME ALL RESPONSIBILITY AND COSTS CONNECTED THEREWITH TO PROTECT, <br />MAINTAIN AND REPAIR, WHERE NECESSARY <br />8. WATER LINE CONSTRUCTION WITHIN THE PROPOSED DEVELOPMENT SHALL NOT COMMENCE UNTIL THE <br />STREET HAS BEEN BROUGHT TO SUB -GRADE, MEETING MUKILTEO WATER DISTRICT APPROVAL. <br />9. WATER MAIN SHALL BE FIELD STAKED PRIOR TO CONSTRUCTION, WITH 25' STAKES ON CURVES. LOT <br />CORNER STAKES SHALL ALSO BE IN PLACE PRIOR TO CONSTRUCTION, <br />I 10. PIPE SHALL BE DUCTILE IRON, AWWA CLASS 52 THICKNESS, WITH RUBBER GASKETS, PUSH -ON TYPE, <br />OR MECHANICAL JOINT, MEETING AWWA SPECIFICATIONS. FITTINGS SHALL BE AWWA, CEMENT LINED, <br />DUCTILE IRON, AND EITHER MECHANICAL JOINT OR FLANGED, AS INDICATED HEREIN. <br />11, UNLESS OTHERWISE SPECIFIED VALVES 12" AND SMALLER SHALL BE DUCTILE IRON RESILIENT SEATED <br />GATE VALVES: ACCEPTABLE VALVES ARE MUELLER, CLOW, M&H, U.S. PIPE AND AMERICAN FLOW <br />CONTROL, SERIES 2500. VALVES LARGER THAN 12" SHALL BE DUCTILE IRON BUTTERFLY VALVES; <br />ACCEPTABLE VALVES ARE PRATT GROUNDHOG, DRESSER 450 AND MUELLER LINESEAL III. <br />12. <br />ALL WATER WORKS FITTINGS AND BOLTED ASSEMBLIES SHALL BE COMPLETELY COVERED WITH <br />VISQUEEN PLASTIC, 4 MIL. THE END OF THE PLASTIC SHALL BE TAPED TO SECURE THEM TO THE <br />FOUND REBAR & CAP <br />PIPE <br />IS 9435" <br />13. <br />HYDRANTS SHALL BE MUELLER CENTURION A-423, CLOW MEDALLION, OR DRESSER RELIANT 929 <br />MEETING AWWA SPECIFICATIONS. HYDRANTS SHALL BE FURNISHED WITH THREADED OUTLETS, MEETING <br />FIRE DISTRICT/DEPARTMENT STANDARDS. BOTH THRUST BLOCKING AND MEGA LUGS RESTRAINTS ARE <br />REQUIRED ON EACH HYDRANT INSTALLATION. HYDRANTS WITHIN THE CITY OF MUKILTEO FIRE SERVICE <br />AREA AND FIRE DISTRICT #1 SHALL BE EQUIPPED WITH 4-INCH STORZ ADAPTERS, ALL OTHER <br />HYDRANTS SHALL UTILIZE A 5-INCH STORZ ADAPTER. ALL HYDRANTS SHALL HAVE A 4 X" NST <br />THREADS ON PUMPER PORT <br />74. <br />PROVIDE THRUST BLOCKING AND/OR RESTRAINED JOINTS AT ALL FITTINGS AND BENDS AND <br />UP -THRUST FITTINGS, IN ACCORDANCE WITH DISTRICT STANDARDS, CONDITIONS AND SPECIFICATIONS. <br />15. <br />ALL NEW CONNECTIONS TO THE EXISTING WATER SYSTEM SHALL BE IN STRICT CONFORMANCE WITH <br />THE APPROPRIATE SUBSECTIONS OF THE SPECIFICATIONS OF THE DISTRICT. NO CONNECTION SHALL <br />BE MADE BETWEEN THE NEW MAIN AND THE EXISTING MAINS UNTIL THE NEW PIPING HAS BEEN <br />FLUSHED, DISINFECTED, TESTED AND RECEIVED SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br />16. <br />INDIVIDUAL WATER SERVICES TO THE PROPERTY LINE SHALL BE 1 " DIAMETER MINIMUM SIZE AND BE <br />INSTALLED WITH 36" MINIMUM COVER. - <br />17. <br />BACKFLOW PREVENTION ASSEMBLIES SHALL BE INSTALLED ON ALL RESIDENTIAL FIRE SPRINKLER <br />SYSTEMS AND LOCATED IMMEDIATELY BEHIND THE WATER METER ON THE PROPERTY SIDE. <br />18. <br />ALL COMMERCIAL, MULTI -FAMILY, INDUSTRIAL AND IRRIGATION SERVICES SHALL INCLUDE A DOH <br />f INLINK FENCE <br />APPROVED BACKFLOW PREVENTION ASSEMBLY LOCATED ON THE PROPERTY SIDE OF THE WATER <br />METER. ALTERNATE LOCATIONS MAY BE ACCEPTABLE UPON APPROVAL BY MUKILTEO WATER DISTRICT. <br />STRUCTURES REQUIRING FIRE SPRINKLER SYSTEM SHALL HAVE AT LEAST ONE BACKFLOW PREVENTION <br />KEYSTONE <br />ASSEMBLY PER EACH STRUCTURE, PROTECTING THE POTABLE WATER SYSTEM FROM THE FIRE <br />SYSTEM.. THE BACKFLOW PREVENTION ASSEMBLY SHALL BE LOCATED IN A FLOOD PROOF VAULT OR <br />SERVICE BOX, DEPENDING ON SIZE, OUTSIDE THE STRUCTURE IN A LOCATION APPROVED BY THE <br />MUKILTEO WATER DISTRICT, <br />19. <br />WHERE ROAD GRADES ARE ESTABLISHED, PROVIDE A MINIMUM OF 48" COVER OVER 12" OR LARGER <br />WATER MAINS, AND PROVIDE A MINIMUM OF 42" COVER OVER 8" MAINS; OR ADDITIONAL DEPTH AS <br />REQUIRED TO MISS OTHER UTILITIES. <br />20. <br />WATER MAINS CONSTRUCTED WITHIN EASEMENTS OR PRIVATE ROADS SHALL BE INSTALLED WITH <br />POLYETHYLENE ENCASEMENT RESTRAINED JOINTS AND WITH A 5'-0" MINIMUM COVER. DURING <br />BACKFILL OPERATIONS, FURNISH AND INSTALL 3" WIDE METALLIC MARKER TAPE WITH 3 FEET OF <br />COVER OVER WATER MAIN: <br />21. <br />MINIMUM RADIUS FOR 12" AND SMALLER PIPELINES CONSTRUCTED ON CURVES (4 DEGREE <br />DEFLECTION PER JOINT) IS 258 FEET <br />22. <br />COMPACTION: ALL TRENCH BACKFILL AND ROADWAY EMBANKMENT SHALL BE COMPACTED TO 95% OF <br />MODIFIED PROCTOR DRY MAXIMUM DENSITY IN ACCORDANCE WITH ASTM_ D1557, EXCEPT THE TOP 6" <br />IN PAVED AREAS, WHICH SHALL BE 100 <br />23. <br />CONSTRUCTION INSPECTION WILL BE DONE BY MUKILTEO WATER DISTRICT AND/OR THEIR DESIGNATED <br />ENGINEER. NO NEW UTILITY FACILITIES WILL BE ACCEPTED BY THE DISTRICT IF PROPER INSPECTIONS <br />HAVE NOT BEEN COMPLETED. <br />24. <br />THE WATER MAIN CONSTRUCTION PHASE WILL NOT BE CONSIDERED COMPLETE UNTIL THE <br />AINLINK FENCE <br />INSTALLATION IS ACCEPTABLE TO THE DISTRICT INCLUDING A SATISFACTORY HYDROSTATIC PRESSURE <br />TEST, A SATISFACTORY DISINFECTION TEST, SATISFACTORY FLOW OF SERVICE LINES, AND COMPLETION <br />OF ALL ITEMS ON THE INSPECTOR'S PUNCH LIST. <br />25. <br />WATER SERVICE IS AVAILABLE ONLY AFTER TRANSFER OF OWNERSHIP TO THE DISTRICT AND AFTER <br />(DEAD) PAYMENT OF ALL CURRENT APPLICABLE FEES. <br />CQ <br />' 13'50 "W11A 119.00' <br />7 ' 1 <br />IE=549.26' (12" PVC ) REA'CHAIN RB <br />NK <br />2'X6' JERSEY F CE W/BARB <br />BARRIER 2' HIGH IE=549.29' (12" PVC ) WIRE TOP <br />IE=549.64' (6" PVC E) <br />FOUND REBAR & CAP IE=549.29, 12"0(W) NE41 <br />"G4 INC 9435" <br />I <br />I <br />PER BMPT5.10C FIG. III-3.1.8 OF 2014 SWMMWW <br />PLAN APPROVED <br />h <br />PUBLIC SERVICES %TEO <br />�: <br />DRAINAGE EROSION <br />. <br />ANY CONSTRUCTION ON ZIS <br />Llc <br />PR03ECT. APPROVAL FOR TFIS <br />PROM 15 CONDMONAL. PER <br />M� f� <br />R <br />NOTES. - <br />EXISTING SIDE SEWER AND WATER METER <br />TO REMAIN AND SHALL BE USED FOR THE <br />PROPOSED BUILDING. <br />REV, NO. <br />DESCRIPTION <br />05-17-2018 <br />INSIGHT ENGINEERING CO. <br />P.O. BOX - 1478 <br />EVERETT, WA 98206 <br />(425) 303-9363 (425) 303-9362 FAX <br />INFO@INSIGHTENGINEERING.NET <br />SITE ADDRESS 10611 EVERGREEN WAY, <br />EVERETT, WA. 98204 <br />INITIALS DATE TAX ACCOUNT NO.'S: 28042400203100 <br />ev" tL <br />wW <br />S V r/4;1 1/4�`C"24j.24N., R�04E..�1G1. Uj a <br />KLEIN HONDA Li- w <br />DWG FILENAME DESIGNED BY: DATE: SCALE: JOB NO.: Fes- W <br />170887.DWG JRC 10-13-2017 1 "=30' 17-0887 > <br />t_l..' <br />PAVING AND SHEET O <br />UTILITYPLAN C3.O <br />