My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
932 E MARINE VIEW DR 2019 Plans 2022-12-01
>
Address Records
>
E MARINE VIEW DR
>
932
>
Plans
>
932 E MARINE VIEW DR 2019 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:32:34 AM
Creation date
7/20/2022 3:01:22 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
932
Permit
BW1911-003
Year
2019
Notes
REPLACE DECK FRONT OF HOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE EXPOSURE & COMPRESSIVE DESIGN STRENGTHS - <br />DESIGNATION <br />CONDITIONS <br />EXPOSURE <br />MIN. Vc <br />- --- - __ <br />CLASS <br />(psi) <br />HEATED. SLABS, BEAMS, <br />GIRDERS, COLUMNS, PIERS, AND <br />INTERIOR CONC. <br />FO <br />2500 <br />BURRIED FOOTINGS <br />FOOTINGS <br />FOUNDATION WALLS, UNHEATED. <br />- <br />- <br />SLABS, BEAMS, GIRDERS, <br />UNSATURATED <br />COLUMNS, PIERS, PILE CAPS, <br />EXTERIOR CONC. <br />F1 <br />3500 <br />SHEAR WALLS <br />3. ALL CONCRETE WITH A DESIGNATED COMPRESSIVE STRENGTH EXCEEDING <br />2500 PSI SHALL REQUIRE SPECIAL INSPECTION BY AN INSPECTOR APPROVED <br />BY THE BUILDING DEPARTMENT AND THE ENGINEER, EXCEPTION: NO <br />INSPECTION IS REQUIRED WHERE CONCRETE EXCEEDING 2500 PSI IS <br />DESIGNATED FOR WEATHERING PURPOSES ONLY. <br />4. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, CSA NORMAL. <br />5. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. <br />O. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 301. <br />79 CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM <br />OF FIVE (5) DAYS AFTER PLACEMENT® ALTERNATE METHODS WILL BE <br />APPROVED IF SATISFACTORY PERFORMANCE CAN BE ASSURED, <br />8. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL CASES, ALL <br />CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND ALL LAITANCE <br />SHALL BE REMOVED, ALL VERTICAL JOINTS SHALL BE THOROUGHLY WETTED <br />AND SLUSHED WITH A COAT OF NEAT CEMENT IMMEDIATELY BEFORE PLACING <br />NEW CONCRETE. <br />. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT, POUR JOINTS <br />SHALL BE LOCATED TO MINIMIZE EFFECTS OF SHRINKAGE AS WELL AS PLACED <br />AT POINTS OF LOW STRESS® MAXIMUM AREA OF POUR JOINTS IS 400 SF. <br />10. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR FORMED WORK <br />SHALL BE S FOLLOWS: <br />EXP ED TO - OR EAT 5 OR SMALL . 1 l9 <br />EXPO EARTH WE HER (# OR L ER): 2 <br />COVERAGE NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3" MINIMUM <br />11. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN <br />STRUCTURAL CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED, <br />1 2. LEAN CONCRETE SHALL BE 2 SACKS OF CEMENT PER CUBIC YARD OF <br />CONCRETE. <br />13. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE WITH ACI 318. <br />14. CONCRETE EXPOSED TO SULFATES, CONCRETE WITH LOW PERMEABILITY <br />REQUIREMENTS, AND CONCRETE WITH CHLORIDE ION CONTENT REQUIRE <br />ADDITIONAL MIX DESIGN CONSIDERATIONS. IN THE EVENT OF THESE <br />REQUIREMENTS THE ENGINEER SHALL BE NOTIFIED BY THE CLIENT IN A <br />WRITING AND DESIGN MIXES SHALL BE PROVIDED PER ACI 318. <br />CEMENT CONTENT <br />F9c PSI LBS/CUBIC YARD SACKS PER CUBIC <br />( ) (MIN®) YARD (MIN.) NOTES <br />-- 2500 — = 470 - - - 5 NOTE A - <br />3500- <br />NOTE 1. MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR <br />-LESS. NO MORE THAN A 1" PLUS TOLERANCE SHALL BE ALLOWED. <br />NOTE ?e AIR ENTRAINMENT IS REQUIRED FOR ALL CONCRETE EXPOSED TO <br />WEATHER. FOR %" AGGREGATE AN ENTRAINMENT OF O% IS REQ'D. FOR Y2" <br />AGGREGATE AN AIR ENTRAINMENT OF 7% IS REQ'D. <br />NOTE 3: POZZOLANS ARE NOT PERMITTED IN THE MIX DESIGN UNLESS <br />APPROVED BY THE ENGINEER. <br />A) WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER SECTION 1704.4 OF <br />THE I.B.C,, CONCRETE SHALL HAVE A MINIMUM CEMENT CONTENT OF 5 SACKS <br />PER CUBIC YARD OF CONCRETE. <br />B) FOR STRENGTHS ABOVE 4000 PSI, PROPORTIONS SHALL BE ESTABLISHED <br />BY THE METHODS SPECIFIED ACI 318. <br />C) DESIGN MIX (OTHER THAN AS.SPECIFIED IN THIS TABLE) SHALL BE <br />SUBMITTED TO THE BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST USE. <br />7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION <br />TO ANY OTHER SPECIFIC DETAIL CALLED OUT, <br />. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE <br />AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES, PIPE SLEEVES, <br />ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR <br />OTHERWISE INCORPORATED IN STRUCTURAL WORK, <br />O. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR <br />HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED <br />MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. <br />10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS <br />IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF <br />ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY <br />SHALL BE REPORTED TO THE ENGINEER SO THAT THE PROPER REVISIONS MAY BE <br />MADE, MODIFICATION TO DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT <br />PRIOR WRITTEN APPROVAL OF THE ENGINEER. <br />11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE <br />STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL <br />CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, <br />ELEVATIONS, DIMENSIONS AND LOCATIONS OF ALL OPENINGS, ETC® <br />42" I <br />4 1 t'.4.� <br />® I B <br />L24" 0- <br />PT 6xC <br />HF2 POST <br />CONCRETE <br />FILLED HOLE <br />(1)#4 BAR EACH <br />WAY THROUGH POST <br />D POST CONNECTION <br />M PER PLAN <br />POST PER PLAN <br />TYP. POST TO BEAM <br />PROVIDE 2" l <br />MINIMUM EDGE <br />DISTANCE AN[ <br />ROW SPACING <br />HDU2-SDS2.5 0 EP <br />END OF EACH DECk <br />(TYP) <br />RIM JOIST <br />PLAN 1Y4" <br />WI <br />PER PLAN <br />PER t <br />�?x HFZ LEDGER <br />DEPTH TO MATCH JOISTS) <br />-JOIST AND <br />HANGER PER <br />CLAN <br />TYPICAL LEDCER CONNECTION <br />CITY OF EVERETT <br />I% V € I=r, NE fin) FOR P E YW IT <br />L <br />On <br />c\j <br />Ln <br />L <br />U- <br />Q) <br />c <br />u_j <br />L <br />C\J <br />0 <br />(0 <br />V l <br />Lu <br />I <br />I <br />I <br />I <br />w <br />O <br />ua <br />�p0 <br />uj <br />Lu <br />0 <br />LLJ <br />u.a <br />m <br />L-wr 2 7 21 <br />Drawn By: VKY <br />Checked By: CHR15 <br />Date: 12-2G- 19 <br />SDA JOB NO. <br />14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.